Summary of Contents for DORIC NC500

  • Page 1 Neuroscience Console 500 User Manual Version 1.0.0...
  • Page 2: Table Of Contents

    2 Operations Guide 2.1 Connecting the Neuroscience Console 500 ........
  • Page 3: Overview

    Doric Fiber Photometry Console. It has been developed in parallel with a new version of the Doric Neuroscience Studio to manage multiple data sources and visualize multiple data streams in a user-friendly and efficient interface.
  • Page 4: Ports Presentation

    • Keypress event for manual behavior event tagging during recording 1.2 Ports presentation The Neuroscience Console 500 is equipped with different types of dedicated ports that can be used separately or in combination with one another for multi-modalities experiments (Fig 1.2a, 1.2b): •...
  • Page 5 (a) Front view (b) Back view Figure 1.2: Neuroscience Console 500 connectivity Figure 1.3: DB25 port pinout description Chapter 1. Overview...
  • Page 6: Operations Guide

    • Connect outputs (optional). The console can send TTL pulses or analog outputs to other devices. Connect these devices to the Digital I/O or Analog Out port of the Neuroscience Console 500 with a BNC cable. • Connect inputs (optional). Digital inputs receive TTL pulses while analog inputs receive analog signals ( 10 V signals) that can be displayed and saved using the Doric Neuroscience Studio.
  • Page 7: Specifications

    Specifications 3.1 General specifications Table 3.1: General specifications for the Neuroscience Console 500 SPECIFICATION VALUE NOTES Digital I/O Number of ports Maximum sampling rate 50 kSps Maximum output frequency 20 kHz Interface 8 BNC I/O + 1 DB25 (8 I/O + 8 Input...
  • Page 8: Environmental Specifications

    to allow a better noise performance. When starting an acquisition, the input data rate (Samples per second) can be selected according to the needs of each test. Higher data rate provides higher RMS noise. Analog inputs are reversed and then calculated as an average of two conversions in order to reduce the offset error. Table 3.2: Analog input noise and resolution specifications with chopping mode enabled Time - 3dB...
  • Page 9: Support

    4.2 Warranty This product is under warranty for a period of 12 months. Contact Doric Lenses for return instructions. This warranty will not be applicable if the unit is damaged or needs to be repaired as a result of improper use or operation outside the conditions stated in this manual.