SPLIT AIR-CONDITIONER
OWNER'S MANUAL
AIRMASTER
1 JOYNTON AVENUE
WATERLOO NSW 2017 AUSTRALIA
TEL: (02) 9313 7111
FAX: (02) 9313 7555
www.palsonic.com.au
AIRMASTER CUSTOMER SERVICE
TELEPHONE
AUSTRALIA: 1300 657 888
Thank you for selecting super quality Air Conditioner. To ensure satisfactory
operation for many years to come, this Owner's Manual should be read carefully
be fore using your air conditioner. After reading. store it in a Safe place. Please refer
to the manual for questions on use or in the event that any irregularities occur.
This Air Conditioner should be used for household use.

Advertisement

Table of Contents
loading

Summary of Contents for Palsonic AOS

  • Page 1 AIRMASTER 1 JOYNTON AVENUE WATERLOO NSW 2017 AUSTRALIA TEL: (02) 9313 7111 FAX: (02) 9313 7555 www.palsonic.com.au AIRMASTER CUSTOMER SERVICE TELEPHONE AUSTRALIA: 1300 657 888 Thank you for selecting super quality Air Conditioner. To ensure satisfactory operation for many years to come, this Owner's Manual should be read carefully be fore using your air conditioner.
  • Page 2: Table Of Contents

    CONTENTS Safety Precautions ........................Identification of Parts ......................... Remote Controller ........................Operation Instructions ....................... Maintenance ..........................Protection ..........................Troubleshooting ......................... Installation Instructions ......................Preparation before use Before using the air conditioner, be sure to check and preset the following. Remote Controller presetting The remote controller is NOT presetting as Cooling Only Air Conditioner or Heat Pump by manufacturer.
  • Page 3: Safety Precautions

    Safety precautions Symbols in this Use and Care Manual are interpreted as shown below. Be sure not to do. Be sure to follow this instruction. The feature of the appliance, Grounding is essential. instead of a fault. Warning: Incorrect handling could Pay attention to such a situation.
  • Page 4: Identification Of Parts

    Identification of parts Indoor unit Air intake Front Panel Emergency Panel Display Panel Air Outlet Vertical Adjustment Louvre Horizontal Adjustment Louvre Charcoal Filter (optional) Electrostatic Filter (optional) Air Filter Remote Controller Air Intake Outdoor unit Drain Hose Note: Condensate water drains at COOLING or DRY operation Pipes and Power Connection Cord...
  • Page 5 Identification of parts Operating and Display Signal Receives Sleep Indicator Receive signal from the remote controller. It lights up during the set sleep function. Timer Indicator It lights up during the set time. Power Indicator It lights up when power supply is on. Run Indicator It is on during operation.
  • Page 6: Remote Controller

    Remote controller Remote controller The remote controller transmits signals to the system. Signal Transmitting Window Setting Display transmitting display Transmits signals to the system time setting display ON/OFF button temperature setting display Used to start and stop operation setting temperature adjustment display when pressed.
  • Page 7 Remote controller Remote controller Please slide and remove the cover. How to Insert the Batteries Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of Slide the cover upwardly in the battery are matched correctly.
  • Page 8: Operation Instructions

    Operation instructions FEEL mode operation procedure Operates by selecting automatically the operation mode ( HEAT, DRY, FAN , COOL ) depending on the room temperature during starting. With the remote controller pointing towards the air conditioner. Turning on Press button, when the appliance receives the ON/OFF signal, the RUN indicator of the indoor unit lights up.
  • Page 9: Timer Setting

    Operation instructions TIMER mode It is convenient to set the timer on with the TIMER button when you go out in the morning to achieve a comfortable room temperature when you get home. You can also set timer off at night to enjoy a good sleep. Timer Setting SLEEP TIMER ON TIMER OFF...
  • Page 10: Maintenance

    Maintenance Front panel maintenance Air filter maintenance Cut off the power supply It is necessary to clean the air filter after using it for about 100 hours. Turn off the appliance first before disconnecting Clean it as follows: from power supply Stop the appliance and remove the air filter.
  • Page 11: Protection

    Protection Operating condition Noise pollution The protective device may trip and stop the appliance in cases listed below. Install the air conditioner at a place that can bear its weight in order to operate Outdoor air temperature is over 24 more quietly.
  • Page 12: Troubleshooting

    Troubleshooting The following cases may not always be a malfunction, please check it before asking for service. Trouble Analysis If the plug is not properly plugged in. If batteries in the remote controller are exhausted. Does not run. If the protective device works to protect the appliance.
  • Page 13: Installation Instructions

    Installation instructions Distance from ceiling Installation diagram should be over 50 mm Distance from wall should be over 50mm Distance from the wall should be over 50mm Distance from floor should be over 2500mm Air intake distance from the wall Air intake distance from should be over 250mm the wall should be...
  • Page 14 Installation instructions Connecting the Cable Front panel Wiring between the indoor and outdoor units: Terminal (inside) Remove the PCB cover from the indoor unit; Refer to the wiring diagram attached to indoor unit Cover Cover when connecting cords to indoor unit terminals; Reinstall the PCB cover.
  • Page 15 Installation instructions Indoor unit installation 1. Installing the Mounting Plate Decide an installing location for the mounting plate according to the indoor unit location and piping direction. Keep the mounting plate horizontally with a horizontal ruler or dropping line. Drill holes of 32mm in depth on the wall for fixing the plate. Insert the plastic plugs to the hole, fix the mounting plate with tapping screws.
  • Page 16 Installation instructions NOTE Piping Joints Thermal Insulation: Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape. wrapped with vinyl type Piping Thermal Insulation: Thermal insulation a .Place the drain hose under the piping. b. Insulation material use polythene foam over 6mm in thickness. Large pipe Thermal insulation Note: Drain hose is prepared by user.
  • Page 17 Installation instructions 4. Connecting the Cable Front panel Terminal (inside) Indoor Unit Connect the power connecting cord to the indoor unit by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit Cabinet connection.
  • Page 18 Installation instructions Outdoor unit installation 1. Install Drain Port and Drain Hose (for heat-pump model only) The condensate drains from the outdoor unit when the unit operates in heating mode. In order to protect the environment, install a drain port and a drain hose to direct the condensate water. Just install the drain port and rubber washer to the chassis of the outdoor unit, then connect a drain hose to the port as the right figure shown.
  • Page 19 Installation instructions How to Purge Air Tubes: (1) Unscrew and remove caps from 2 and 3-way valves. (2) Unscrew and remove cap from service valve. (3) Connect vacuum pump flexible hose to the service valve. (4) Start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes. (5).
  • Page 20 AIRMASTER 1 JOYNTON AVENUE WATERLOO NSW 2017 AUSTRALIA TEL: (02) 9313 7111 FAX: (02) 9313 7555 www.palsonic.com.au AIRMASTER CUSTOMER SERVICE TELEPHONE AUSTRALIA: 1300 657 888 1130010274...