Table of Contents 1. Application Notes 2. Safety Instructions 3. Precautions in Use 4. Installation and Commissioning 4.1 Installation Environment 4.2 Installation Site 4.3 Preparation before Use 4.4 First Power-on 4.5 Operation after Power Failure 5. Product Composition and Overview 6.
1. Application Notes Thank you for choosing and using MELING BIOMEDICAL products! For your safe and convenient use and reasonable maintenance of the equipment, please read the Operation Instructions carefully before use and keep it properly for reference. The equipment operator can copy some chapters of this operation manual, but only for internal use, for example, to instruct the user how to deal with emergencies.
2. Safety Instructions When using this product for the first time, please pay attention to the meaning of the following warning signs and carefully read the safety precautions, so that you can use this equipment safely and correctly. Warning: crushing of hands. Beware of fire.Warning;flammable material Manufacturer Series NO...
Page 8
It is forbidden to disassemble and modify this equipment without authorization, so as to avoid potential safety hazards. In this case, MELING BIOMEDICAL will not bear any responsibility for quality accidents. It is forbidden to put inflammable and explosive dangerous goods, strong corrosive acids, alkalis and other items unsuitable for the equipment in the equipment.
3. Precautions in Use ® Before putting the items into the equipment, please confirm that the temperature in the freezer storage chamber has reached the set value first, and then put the articles in batches. Every time you put in items, they shall not exceed 1/3 of the inner volume of the freezer storage chamber so as to prevent excessive temperature rise.
2.Inventory of accessories: Please check the accessories and materials according to the packing list. 3. Cleaning: Clean the product once before use. 4.Before use, remove the small wire shelf and put it at the bottom of the cabinet (applicable to YC-55L/YC- 55EL /YC-56L/YC-56ELand YC-75L/YC-75EL/YC-76L/YC-76EL).
4.5 Operation after Power Failure 1. The equipment has a memory function for the set value. When the power is restored after power failure, the equipment will continue to operate before power failure. 2. Once the equipment is powered off, it requires 5 minutes before it can be switched on again, so as to avoid damaging the compressor.
Door body Adjust feet Figure I YC-55L (It can be used as reference for YC-55EL, YC-56L,YC-56EL,YC-75L,YC-76L, YC-75EL, YC-76EL) The YC-55L/YC-56L/YC-55EL/YC-56EL refrigerator has two shelves, each with a capacity of 13Kg. The YC-75L/YC-76L/YC-75EL/YC-76EL refrigerator has three shelves, each with a capacity of 13Kg.
Page 13
access port Loading capacity Model Shelves (kg) YC-315L YC-330L YC-395L YC-395EL YC-400L YC-400EL YC-525L YC-525EL Caster Adjust feet Figure III YC-395L(It can be used as reference for YC-315L,YC-315EL,YC-330L,YC-330EL, YC-395EL, YC-400L, YC-400EL and YC-525L,YC-525EL) Door body Loading capacity Model Shelves (kg) Door handle YC-650L Caster...
Page 14
Display panel (power switch on the back) USB interface Door lock access port Door handle Door body Loading capacity Model Shelves (kg) Cabinet YC-725L YC-725EL YC-1015L 27.5 YC-1015EL YC-1320L Caster Figure V YC-725L( YC-725EL,YC-1015L,YC-1015EL,YC-1320L) (It can be used as reference for access port Door handle Door body...
6. Operating Instructions 6.1 Function Introduction This series of products include two control systems, based on which different adjustment methods apply. Please select the proper adjustment method according to the type of control system with the storage box you purchased. Printer (optional) Type A control panel 1.
Page 16
temperature display window, which displays the average temperature inside the cabinet in °C under normal operation; View ambient temperature: In the key lock state, press key, and digital tube displays the ambient temperature, and returns to normal ...
Page 17
2. Function setting of Type A control panel 1) After powering on, the equipment can enter the working state; 2) User parameter settings: Unlock:under normal operating state,simultaneously press keys for 3s and the digital tube will display the parameter code”0000";By pressing to enter the password”0005"and holding to unlock.
Page 18
Suggested Menuitem Parameter Range Remarks settings Mode 1: It shall be judged as once after the door is opened and closed once and heated for 5min 1.(Set to 4 (time setting). If the door is opened and closed when again during the heating period, the heating time the door is with will be updated again;...
Page 19
°C DOOR ALARM Ref. TEMPERATURE CONTROL PRINT (optional) (optional) Type B control panel 1. Function description of Type B control panel (Applicable to YC-130L YC-130EL) It is temperature display window, which displays the average temperature inside the cabinet in °C under normal operation;...
Page 20
In unlock state and parameter setting mode, press this key to display parameter values and parameter names. If the pressing time is longer than 3 seconds, save the settings and return to the normal interface. i. USB interface Automatic export of USB data: When the USB interface is connected to the USB flash drive, the buzzer of the recorder beeps once, displaying "ON", and PDF files of the data of the current month and the previous month are generated in the USB flash drive.
Page 21
3. Parameter display Suggested Menuitem Parameter Range Remarks settings The highest temperature since last clerance The lowest temperature since last clerance Clearance of the Max and Min temperature records 0.0-10.0 Temperature setting Set value of high temperature alarm set+H; When H =0, High temp alarm is disabled; When 0.0-10.0 the alarm is over high temp alarm set, H1 will be displayed on the controller...
Page 22
Quick setting of time after power on After the power-on self-test on the display board is completed, the quick setting menu is displayed. Menu item Menu Menu description Set range Default Unit Set logger module time - year 10~50 Set logger module time - month 1~12 Set logger module time - day 01~31...
6.2 Optional function 6.2.1 Printer The printer has been installed with a paper roll at the factory. If the paper roll is used up after a long period of use, you can buy the same paper roll (size: thermal paper, paper width: 57.5±0.5mm, the outer diameter of the reel: not greater than 40mm, i.e., RM57*40 back-roll paper) Description of printer panel: ①...
7. Maintenance and Service Warning: In order to prevent people from getting electric shock or injury, please cut off the power supply of the equipment before ® any repairs and maintenance. Make sure you don't inhale drugs or suspended particles around it when maintaining the equipment, otherwise it will ®...
Lighting damage Please call the after-sales telephone and contact after-sales service personnel of (refrigeration MELING BIOMEDICAL for replacement. Please do not replace the parts by yourself. equipment) The following conditions are not faults ①When the compressor starts and stops, the equipment parts will make a slight impact sound;...
Notes: The equipment can only be repaired, maintained or improved by the engineers certified by MELING BIOMEDICAL, ¿ so as to ensure the normal operation of the equipment and the compliance with corresponding safety standards. Please clean and disinfect the equipment before notifying the maintenance engineer; During the warranty period of ¿...
Page 27
Exterior ( ( ) ) Refrigerant Rated Rated Temp Rated Ambient Climate Volume Weight dimensions Model temperature andloading voltage frequency Range current type (kg) (DxWxH) (℃) amount (V~) (Hz) (°C) (mm) YC - 55L R600a/ 16 ~32 1.16 560X540X632 ( )...
Page 28
Exterior ( ( ) ) Refrigerant Rated Rated Temp Rated Ambient Climate Volume Weight dimensions Model andloading voltage frequency Range current temperature type (kg) (DxWxH) (℃) amount (V~) (Hz) (°C) (mm) YC - 525L 16 ~32 R290/75g 810X720X1973 ( ) Spraying aluminum liner YC - 525L 16 ~32...
Page 29
Exterior ( ( ) Ambient Refrigerant Rated) Rated Temp Rated Climate Volume Weight dimensions Model temperature and loading voltage frequency Range current type (kg) (DxWxH) ( ) (°C) amount (V~) (Hz) (°C) (mm) YC - 55L YC - 55EL 16 ~32 R600a/16g 220-240 560X540X632 (...
Page 30
Exterior Ambient Refrigerant (Rated) Rated Temp (Rated) Climate Volume Weight dimensions Model temperature andloading voltage frequency Range current type (kg) (DxWxH) ( ) °C amount (V~) (Hz) (°C) (mm) YC - 130L ( ) 16 ~32 R134a/110g 220-240 50/60 625X650X810 Spraying aluminumliner (without disc recorder) YC - 130L...
10. Packing List Certificate of Operation Manual Item Accessory package Conformity Quantity * The door handle accessory applies to: models YC-650L,YC-725L, YC-1015L, YC-1320L, YC-1505L; * The specific packing list shall be subject to the physical objects received.
Page 32
Zhongke Meiling Cryogenics Company Limited Address: No 1862 Zishi Road, Hefei City, Anhui, P.R. China Production Address: No.1862 Zishi Road, Economic and Technological Development Zone, Hefei City Post Code: 230601 Material Code: 890375561 Email: zkmeiling@zkmeiling.com; technical.service@zkmeiling.com Website: www.melingbiomedical.com Production Date: See nameplate on the freezer body Prepared in: August 2023...
Need help?
Do you have a question about the YC-130L and is the answer not in the manual?
Questions and answers