Desa REM10PT RH10PT Owner's Operation And Installation Manual page 6

Blue flame vent-free propane/lp gas heater
Table of Contents

Advertisement

INSTALLATION
6
Installing Heater To Wall (Cont.)
Connecting to Portable Cylinder Gas Supply
INSTALLATION
Continued
Installing Bottom Mounting Screw
1. Locate bottom mounting hole. This hole is near bottom on back
panel of heater (see Figure 9).
2. Mark screw location on wall.
3. Remove heater from wall.
4.
If installing bottom mounting screw into hollow or solid wall,
install wall anchor. Follow steps 1 through 5 under Attaching To
Wall Anchor Method, page 5. If installing bottom mounting screw
into wall stud, drill hole at marked location using 9/64" drill bit.
5. Replace heater on wall.
6. Insert bottom anchor screw through back panel into bottom
anchor or drilled hole (see Figure 9).
7. Tighten screw until heater is firmly secured to wall. Do not
over tighten.
Note: Do not replace front panel at this time. Replace front
panel after making gas connections and checking for leaks (see
pages 9 and 10).
Figure 9 - Installing Bottom Mounting Screw
CONNECTING TO PORTABLE CYLINDER
GAS SUPPLY
WARNING: Review and understand the warnings
in the Safety Information section, page 2. They are
needed to safely operate this heater. Follow all local
codes when using this heater.
WARNING: Test all gas piping and connections
for leaks after installation or servicing. Never use an
open flame to check for a leak. Apply a noncorrosive
leak detection fluid to all joints. Bubbles forming
show a leak. Correct all leaks at once.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
IMPORTANT: You must use a propane/LP gas supply cylinder that
is compatible with the connection device provided with the hose and
regulator.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
1. Remove 90° gas fitting from hardware bag.
2. Apply pipe joint sealant lightly to male NPT threads (see Fig-
ure 10). This will prevent excess sealant from going into pipe.
Excess sealant in pipe could result in clogged heater valves.
3. Hold gas pressure regulator with wrench when connecting the
90° gas fitting. Do not over tighten connection to regulator.
The regulator body could be damaged.
4. Provide propane/LP supply system (see Propane/LP Supply,
page 4).
5. Connect fuel gas fitting on hose/regulator assembly to pro-
pane/LP tank(s). Turn fuel gas fitting counterclockwise into
threads on tank. Tighten firmly using a wrench. IMPORTANT:
Position regulator so that hose leaving the regulator is in a
horizontal position (see Figure 11). This places the regulator
vent in the proper position to protect it from the weather.
6. Connect hose to heater inlet. Tighten firmly using a wrench.
You must use the regulator supplied with heater.
Elbow
Figure 10 - Gas Connection
Propane/LP
Supply
Valve
Propane/LP
Tank
Figure 11 - Regulator Position
Pressure
Regulator
Heater
Cabinet
Apply Sealant To
This End Only
Hose Fitting
Hose To
Regulator
Regulator
Fuel Gas
Fitting
Hose To
Heater
110373-01D