CookRite AT80G6B-O Operating Instructions Manual

Gas restaurant ranges

Advertisement

Gas Restaurant Ranges
Operating Instructions
Before you begin, please read these instructions carefully to
use this product correctly, to make the product perform ideally, and
to avoid hazards.
Models: AT80G4B-O/ AT80G6B-O / AT80G8B-O/ AT80G2B-F/
AT80G2B-C/ AT80G4B-F/ AT80G4B-C/ AT80G6B-F/
AT80G6B-C/ AT80G8B-F/ AT80G8B-C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AT80G6B-O and is the answer not in the manual?

Questions and answers

Summary of Contents for CookRite AT80G6B-O

  • Page 1 Gas Restaurant Ranges Operating Instructions Before you begin, please read these instructions carefully to use this product correctly, to make the product perform ideally, and to avoid hazards. Models: AT80G4B-O/ AT80G6B-O / AT80G8B-O/ AT80G2B-F/ AT80G2B-C/ AT80G4B-F/ AT80G4B-C/ AT80G6B-F/ AT80G6B-C/ AT80G8B-F/ AT80G8B-C...
  • Page 2 Dear customers and users: Thank you for purchasing our products. In order to be able to better use this product, please read these instructions carefully before any operation, and follow the guide, to avoid any unnecessary trouble during using. Please keep this instruction manual in a safe place for convenient reference and operation.
  • Page 3: Table Of Contents

    Gas Restaurant Ranges The Installation, Operation and Maintenance Guide Contents 1. Safety Protection ……………………………………………………3 2. Brief Introduction……………………………………………………3 3. Manufacturer's Authority and Responsibility……………………3 4. Parameter Specifications……………………………………………4 5. Transport and Storage………………………………………………12 6. Installation and Debugging ………………………………………12 7. Safety Notices and Precautions……………………………………15 8. Operating Instructions…………………………………………… 16 9.
  • Page 4: Safety Protection

    1、Safety Protection Please make sure that the operator is an authorized and licensed technician before you allow him/her to install and operate the products. Be sure to strictly follow this instruction guide during installation and using. The manufacturer is not responsible for any dangers or accidents caused by improper operation or maintenance.
  • Page 5: Parameter Specifications

    Be repaired or changed by unauthorized technicians; Use the spare parts or accessories provided by non-manufacturers; Accidents caused by force majeure; Not strictly comply with related guide of this instruction by any reason. 4、Parameter Specifications 4.1、Outline Dimensions(mm) AT80G4B-O - 4 -...
  • Page 6 AT80G6B-O AT80G8B-O - 5 -...
  • Page 7 AT80G2B-F AT80G2B-C - 6 -...
  • Page 8 AT80G4B-F AT80G4B-C - 7 -...
  • Page 9 AT80G6B-F AT80G6B-C - 8 -...
  • Page 10 AT80G8B-F AT80G8B-C - 9 -...
  • Page 11 <Table 1> Overall Oven Packing size Number Model dimensions dimensions L x W x H of oven L x W x H L x W x H AT80G4B-O 600*800*1115 685*995*1025 508*610*330 AT80G6B-O 900*800*1115 985*995*1025 673*610*330 AT80G8B-O 1200*800*1115 1285*995*1025 508*610*330 AT80G2B-F...
  • Page 12 Nozzle No. Per rate Number of Gas Species Total (mm) (MJ/h) burners and Intake Model rate manifold Oven Oven Oven (MJ/h) pressure (kPa) plates plates plates Natural 2.40 2.55 AT80G8B-O Propane 1.40 1.45 ULPG Natural 2.40 AT80G2B-F Propane AT80G2B-C 1.40 ULPG Natural 2.40...
  • Page 13: Transport And Storage

    that this is correct for the gas supply the appliance is being installed for. The gas conversion procedure is detailed in this manual. Supply Pressure required for this appliance is shown in the ‘Gas supply requirements’ section of this manual. Check the gas supply to ensure adequate supply pressure exists.
  • Page 14 Only be installed in accordance with AS/NZS 5601, the local gas, electricity and other relevant codes. 6.1、Unpacking and Installation Please dispose of all packaging materials and residues after unpacking; Check the equipment. If it is damaged, please keep wrappers and receipts which must be signed by the carrier representative (Driver), and contact the carriers to pursue a claim within 15 days after receiving;...
  • Page 15 It may be necessary to adjust the balance of air input by authorized and licensed technicians; Thread glue must be resistant to the action of liquefied petroleum gases. Warning! Use soap water or testing instrument to test whether piping joint leaks or not before using, and forbid using an open flame to test! After installing completely, you should check gas supply pressure.
  • Page 16: Safety Notices And Precautions

    Before using: Whether the machine is tilted? Whether the control panel is damaged? During using: Whether there is strange odor or vibration noise? Whether the burner flame is normal? Any light back or flameout? Whether the power is normal? If any of this case occurs, stop using and turn off gas supply, contact the supplier or service department.
  • Page 17: Operating Instructions

    cause fire, personal injury or even death; Do not use out of doors; Such appliance is used to cook and bake the food and shall not be used for other purposes; The equipment does not contain any user-serviceable parts. Dealers or technicians will repair it.
  • Page 18 in the pipe. Wait a minute, the pilot light will be lighted after the gas extinguished. 8.2 Igniting the main burner(hot plates) evolve the main fire control valve knob anticlockwise after lighting the pilot light, and then the main fire burner is ignited by the pilot light. When knob reaches to "...
  • Page 19 Figure 7 Figure 8 Figure 9 Tip :The pilot light may not be lighted immediately, for existing gas in the pipe. Wait a minute, the pilot light will be lighted after the gas extinguished. 8.4 Igniting the main burner(oven) After the pilot was ignited, the main fire valve was opened ,and turn the thermostat valve knob to the required temperature position,At this moment, the oven burner is ignited.
  • Page 20 8.6 Stove Operation Before using the stove for the first time, please use a mild detergent to wipe it clean. Do not use corrosive or abrasives detergent. Turn the burners on about 15-20 minutes before broiling for preheating, according to the cooking requirement to adjust the flame size. Notice: When first preheating, the furnace will smoke above.
  • Page 21 underside face plate of oven. Caution: Each burner damper has been adjusted before delivery (once air input), Normal use without adjustment but only switching gas. Adjust only by authorized and licensed technicians. 8.8 Exchange main fire nozzle to switch gas source ①...
  • Page 22: Cleaning And Maintenance

    delivery, normal use without adjustment but only switching gas. Adjust only by authorized and licensed technicians. When you change the gas source, you need exchange the corresponding pressure maintaining valve which installed on air intake. See 3&4 in P25. When exchange gas source, adjust the adjusting screw (figure.14、15) with a wrench to meet the normal requirements of pilot light flame.
  • Page 23 Recommended cleaning methods Table3 Items Methods Times Wipe it with a soft cloth and mild Body daily detergent; Turn off valves when not in use; Control panel Wipe panel and control valve knob with daily mild detergent. Pull out catch tray from front body until the equipment cools down.
  • Page 24: Troubleshooting

    10. Troubleshooting Table 4 Possible causes Problem solving Problems 1.Insufficient 1.Contact the local Not lighting pressure in pipe gas supply dept. 2.Nozzle occlusion 2.Dredge nozzle 1.Insufficient 1.Contact the local pressure in pipe gas supply dept. 2.The main fire nozzle 2.Dredge nozzle occlusion Ignite the pilot 3.Gas control valves...
  • Page 25: Schematic Diagram For Installation Of Chimney

    11. Schematic diagram for installation of the chimney Step I Step II ( Insert the chimney into (Fix the chimney with the the corresponding position stove body by self-tapping of stove body) screw) - 24 -...
  • Page 26: Installation Diagram Of Supporting

    12. Installation diagram of supporting bracket - 25 -...
  • Page 27 Notice: 1、Pressure maintaining valve connects with air intake, must be installed by authorized and licensed technicians, to ensure interface tightness. 2、When the regulator is connected, the maximum load value of natural gas can not exceed 1.13kPa, the maximum value of liquefied gas can not exceed 2.75kPa. 3、Screw the hex nut (Fig.16) before connect air intake, ensure gas mark (Fig.17) on the plastic core match with connected gas source, if not, then pull out the plastic core and change another head, insert it again.
  • Page 28 Our products have the advantages of good durability and low maintenance charge. But to update some components and necessary maintenance, can prolong life length of the products. Contact the dealer for assistance. For service and spare part inquiry, please contact following Atosa Catering Equipment Australia Pty Ltd 3-9 Forge Street,Blacktown,Sydney TEL: 1800 886 888...

Table of Contents