Installation - Desa SVYD18NRA Series Owner's Operation And Installation Manual

Desa owner's operation and installation manual unvented (vent-free) gas stove heater svyd18nra, svyd18pra
Hide thumbs Also See for SVYD18NRA Series:
Table of Contents

Advertisement

INSTALLATION

NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri-
mary heat source. If you have a
central heating system, you may
run system's circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualified ser-
vice person must install fire-
place. Follow all local codes.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the heater
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.)
in the air exist, may discolor
walls or cause odors.
8
IMPORTANT: Vent-free heaters add moisture to
the air. Although this is beneficial, installing heater
in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Air
for Combustion and Ventilation, page 5.
CHECK GAS TYPE
Use only the correct type of gas (natural or pro-
pane/LP). If your gas supply is not the correct gas
type, do not install heater. Call dealer where you
bought heater for proper type heater.
is equipped for (natural or pro-
pane/LP) gas. Field conversion
is not permitted.
CLEARANCES TO COMBUSTIBLES
minimum clearances. If you can,
provide greater clearances from
floor, ceiling, and adjoining side
and back walls.
Carefully follow the instructions below. This stove
is a freestanding unit designed to set directly on
the floor. IMPORTANT: You must maintain mini-
mum wall and ceiling clearances during installa-
tion. The minimum clearances are shown in Fig-
ure 4, page 9. Measure from outermost point of
stove top.
Minimum Wall and Ceiling Clearances
(see Figure 4, page 9)
A. Clearances from outermost point of stove top
to any combustible side wall should not be
less than 12 inches.
B. Clearances from outermost point of stove top
to any combustible back wall should not be
less than 6 inches (includes corner installa-
tions).
C. Clearances from the stove top to the ceiling
should not be less than 48 inches.
www.desatech.com
WARNING: This appliance
WARNING: Maintain the
113084-01C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Svyd18pra seriesOxfordVictor hearthSvyd18nraSvyd18pra

Table of Contents