Manual Lubricated air compressor 116 PSI Pressure Applies for: Code Model 23065 COMP-20LP COMP-20LP Read this manual thoroughly CAUTION before using the tool.
Contents CAUTION Technical data Power requirements To gain the best performance of the tool, prolong the duty life, General power tool safety warnings make the Warranty valid if necessary, and to avoid hazards Safety warnings for pneumatic of fatal injuries please read and compressors understand this Manual before using the tool.
Technical data COMP-20LP Code 23065 Description Lubricated air compressor Voltage 127 V Frequency 60 Hz Power Rated: 1-1/2 Hp Maximum: 2-1/2 Hp Max. Working Pressure 116 PSI Air Continuous Flow 4.2 CFM - 40 PSI 3.2 CFM - 90 PSI Tank Capacity 5.2 gal...
General power tools safety warnings WARNING! Read carefully all safety warnings and instructions listed below. Failure to comply with any of these warnings may result in electric shock, fire and / or severe damage. Save all warnings and instructions for future references.
Safety warnings for pneumatic compressors Before using the compressor When using the compressor CAUTION CAUTION • The pressurestat produces sparks when • Do not aim nozzles, sprayers or the air working. If sparks make contact with gasoline vapors or jet towards people or animals. WARNING other solvents they can ignite causing fire or explosion.
Parts Transportation Handle Switch Tank Pressure Gauge Oil Level Output Spy Hole Pressure Regulator Outlet Air Valve Regulated Pressure Gauge Outlet Check Valve Switch Pressure Release Valve Tank Drain Valve Pressurestat Tank pressure gauge Two Air Outlets with Fast Connection System Filter Motor Cover...
Preparation • The air compressor is used to supply energy to pneumatic tools as versatile as power tools are. The tools can be used to drill, screw, hammer, rivet, staple, chisel, polish, blowtorching, cleaning, painting, inflate tires or inflatable items, apply paint or varnish and maintain other tools. •...
Start up Switch ON and OFF Operation • Before operating the compressor set it onto a flat, • Connect one end of the air hose into any of the leveled and solid surface, well ventilated and away from compressors outlets (H). flammable objects like curtains, etc.
Maintenance Oil Change • After the first 50 hours of operation change oil. Remove the drain cap (A). Set the cap back and fill-up with oil as indicated in page 7 (Oil). The later oil changes shall be carried out every 150 hours’ work. Cleaning and Care •...
Troubleshooting Problem Cause Solution The motor is not • No power. • Be sure the cable is connected. Check the fuse-circuit switch. working. • Fuse is blown . • Replace the blown fuse. • Thermal switch is • Press the thermal switch button to restart. activated.
Authorized service centers In the event of any problem contacting a Truper Authorized Service Center, please see our webpage www.truper.com to get an updated list, or call our toll-free numbers 800 690-6990 or 800-018-7873 to get information about the nearest Service Center. AGUASCALIENTES DE TODO PARA LA CONSTRUCCIÓN MORELOS...
Warranty policy Code Model Brand 23065 COMP-20LP Warranty. Duration: 1 year. Coverage: parts, components and workmanship against manufacturing or operating defects, except if used under conditions other than normal; when it was not operated in accordance with the instructive; was altered or repaired by personnel not authorized by Truper .
Need help?
Do you have a question about the 27106 and is the answer not in the manual?
Questions and answers