Electrical Specification: (Table 1)
The device characteristics are measured in the circuit shown in Fig.1.
Table 1. Electrical Specifications
Item
Nominal Center Frequency (f0)
Insertion Loss at f0
Loaded Q
Attenuation
Insertion Phase
Turnover Temperature
Phase Slope
Frequency Temperature Coefficient
Substrate Material
Maximum Rating: (Table 2)
Table 2. Maximum Ratings
Item
Maximum Input Power
Operating Temperature Range
Storage Temperature
Mechanical Specifications: (Fig.2)
Package is designed as small as 3.2x2.5x1.1[mm
Notice:
This part is electrostatic discharge sensitive and may be damaged by improper handling.
Communications Equipment Marketing Department
http://www.jrc.co.jp/jp/product/device/saw/index.html (Japanese)
http://www.jrc.co.jp/eng/product/saw/index.html(English)
JRC SAW FILTER
NSVS981
f0±2MHz
693.483MHz
Communications Equipment Division
10-1, Nishi-Shinjuku 6-chome, Shinjuku-ku,
Tokyo, 160-8328 Japan
Tel. +81 3-3348-3845
Fax. +81 3-3348-3935
(at Room Temperature)
Spec.
693.379~693.587MHz
4.0dB max.
-
20dB
-
32~52ºC
-
-
-
*1: Nominal Phase = 0ºType
Rating
10dBm
-30~+85ºC
-30~+85ºC
3
] for SMD (Surface Mount Device) type.
NSVS981 Apr. 2005
Typ.
693.483MHz
2.5dB
1150
25dB
Reference(*1)
42ºC
0.32deg/kHz
2
-0.045ppm/ºC
Quartz

Advertisement

loading

Summary of Contents for JRC NSVS981

  • Page 1 NSVS981 Apr. 2005 JRC SAW FILTER NSVS981 Application 693.483MHz Data Communications Electrical Specification: (Table 1) The device characteristics are measured in the circuit shown in Fig.1. Table 1. Electrical Specifications (at Room Temperature) Item Spec. Typ. Nominal Center Frequency (f0) 693.379~693.587MHz...
  • Page 2 NSVS981 Apr. 2005 50Ω 50Ω Fig.1 Measuring circuit ( b ) 3. 2±0. 1 ( 2 ) ( a ) ( 1) Marking (1) Lot Number (a) Year ( 1. 35) (b) Month [ 4x] *Oct.--- X Nov.--- Y Dec.--- Z (2) Part number Mark ( 0.
  • Page 3 NSVS981 Apr. 2005 Notice 1. Use this component within operating temperature range. It might not be satisfied with electrical specification without operating temperature range. When it is used less than –30ºC or more than +85ºC, it might be a cause of degradation or destruction of the component.
  • Page 4 NSVS981 Apr. 2005 ‚ ‚ ‚ 50 O *27nH ‚ U 39pF 50 O *27nH ‚ T ‚ ‚ ‚ ‚ FREQUENCY CHARACTERISTICS 33pF *murata LQW18A series Fig.1 Measuring circuit 13.30±0.20 (1.26±0.13) J4Y1 VS971 CH1: Center 693.483 Span: 10 CH2: Center 693.483 Span: 10 (R0.3)