Interra ITR104 Product Manual

Interra ITR104 Product Manual

Knx universal interface

Advertisement

Quick Links

KNX Universal Interface
2, 4 or 6 Channels
Product Manual
PM190207005BEN
©2019 INTERRA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ITR104 and is the answer not in the manual?

Questions and answers

Summary of Contents for Interra ITR104

  • Page 1 KNX Universal Interface 2, 4 or 6 Channels Product Manual PM190207005BEN ©2019 INTERRA...
  • Page 2 FITNESS FOR PURPOSE. Interra disclaims all liability arising from this TS EN ISO 9001:2008 information and its use. Use of Interra devices in life support and/or safety applications is entirely at the buyer’s risk, and the buyer agrees to defend,...
  • Page 3 To obtain the most up-to-date version of this product manual, please visit our Web site at: http://www.interra.com.tr You can determine the version of a Interra document examining its literature number found on the bottom right corner of any page. The first two letters of the literature are the type of document. The numbers that follow are the creation date of the document and the last letter is the version (e.g., PM141018001A is the version A of a...
  • Page 4 Application Program: 2, 4 or 6-Channel Binary Input Module Product family: Binary Input Module Product name: 2, 4 or 6-Channel Binary Input Module Media Type: Twisted Pair Order number: ITR102, ITR104 or ITR106 TECHNICAL DATA Power supply EIB Power Supply...
  • Page 5: Table Of Contents

    3.5. VALUE ..............................19 3.5.1. Description ............................19 3.5.2. Parameters............................19 3.5.3. Objects ..............................20 3.6. 2-CHANNEL MODE ..........................21 3.6.1. Description ............................21 3.6.2. Parameters............................21 3.6.3. Objects ..............................22 APPENDIX A: CONNECTION DIAGRAM ......................23 PM190207005BEN ©2019 INTERRA...
  • Page 6 Fig3. Toggle Logic without delay ........................13 Fig4. Toggle Logic 2 seconds delay ......................... 13 Fig5. Connecting Diagram ..........................23 Fig6. ITR106 Connection (6 Inputs) ........................23 Fig7. ITR104 Connection (4 Inputs) ........................23 Fig8. ITR102 Connection (2 Inputs) ........................23 PM190207005BEN ©2019 INTERRA...
  • Page 7: Functional Description

    Product Manual 1. FUNCTIONAL DESCRIPTION The KNX universal interface can be configured as 2, 4 or 6 channels depending on the application: ITR102, ITR104 or ITR106. The application program can be loaded with ETS3 or higher and supports the applications which will be described in this manual: - Send switching commands - 1 bit.
  • Page 8: General Parameters

    OBJ NAME FUNCTION TYPE FLAG General Alive Beacon 1 bit This object is only visible when the “Module Alive Beacon” function is enabled. Via the group address linked, the value “true” is sent while the module is running. PM190207005BEN ©2019 INTERRA...
  • Page 9: Functions

    Used energized. Otherwise, any telegram will be sent after first powered on. Periodical Sending Send Always: The current input value will be Don't Send Periodically periodically sent to the bus. Send While Button Pressing PM190207005BEN ©2019 INTERRA...
  • Page 10: Objects

    Switching telegrams are sent via the group address linked with this object. InputX Locking 1 bit CRWU This object is only visible when the locking function is enabled. Via the group address linked, it is possible to lock the current input through the value configured previously. PM190207005BEN ©2019 INTERRA...
  • Page 11: Logic

    KNX Universal Interface Product Manual 3.1.4. Logic Fig 1. Switching Logic without delay Fig 2. Switching Logic with 4 seconds delay PM190207005BEN ©2019 INTERRA...
  • Page 12: Toggle

    Lock On Value 1 Lock Value When locking communication object takes the value 0, status changes at the input are not transmitted. Lock Value When locking communication object takes the value 1, status changes at the input are not transmitted. PM190207005BEN ©2019 INTERRA...
  • Page 13: Objects

    This object is only visible when the locking function is enabled. Via the group address linked, it is possible to lock the current input through the value configured previously. 3.2.4. Logic Fig 3. Toggle Logic without delay Fig 4. Toggle Logic 4 seconds delay PM190207005BEN ©2019 INTERRA...
  • Page 14: Dimming

    Dimming with 2 Buttons: when the contact is closed briefly the value “on” (corresponding to UP direction parameter) or “off” (corresponding to DOWN direction parameter) is sent via “On/Off” object. Otherwise if the the push-button is pressed PM190207005BEN ©2019 INTERRA...
  • Page 15 Lock Value When locking communication object takes the value 1, status changes at the input are not transmitted. This parameter is only visible when the parameter “Selection” is set to “Dimming with 2 Buttons”. PM190207005BEN ©2019 INTERRA...
  • Page 16: Objects

    Shutter/Blinds with two buttons: Two inputs are necessary for this option. With the combination of both push buttons, the blind can be lowered or raised with a long push button action, while a short push button action ends the movement or adjusts PM190207005BEN ©2019 INTERRA...
  • Page 17 Lock On Value 1: When the locking communication object takes the value 1, status changes at the input are not transmitted. This parameter is only visible when the parameter “Selection” is set to “Shutter/Blinds with 2 Buttons”. PM190207005BEN ©2019 INTERRA...
  • Page 18: Objects

    InputX Locking 1 bit CRWU This object is only visible when the locking function is enabled. Via the group address linked, it is possible to lock the current input through the value configured previously. PM190207005BEN ©2019 INTERRA...
  • Page 19: Value

    Lock On Value 1 Lock Value When locking communication object takes the value 0, status changes at the input are not transmitted. Lock Value When locking communication object takes the value 1, status changes at the input are not transmitted. PM190207005BEN ©2019 INTERRA...
  • Page 20: Objects

    This object is only visible when the locking function is enabled. Via the group address linked, it is possible to lock the current input through the value configured previously. * The type of value depends on the selection parameter. PM190207005BEN ©2019 INTERRA...
  • Page 21: 2-Channel Mode

    OFF: when the contact is closed the value “off“ 0…255 is sent. 0…65535 Toggle: when the contact is closed the inverted value of the last sending is sent. 0…13…100% 1-Byte Value: Takes integer values from 0 to 0…20.0…50.0°C 255. 0…300…1000 lux PM190207005BEN ©2019 INTERRA...
  • Page 22: Objects

    Lock Value When locking communication object takes the value 1, status changes at the input are not transmitted. 3.6.3. Objects The objects used through the 2-Channel Mode function have been described above for every single function. PM190207005BEN ©2019 INTERRA...
  • Page 23: Appendix A: Connection Diagram

    KNX Universal Interface Product Manual APPENDIX A: CONNECTION DIAGRAM Fig 5.Connecting Diagram Fig 6.ITR106 Connection (6 Inputs) Fig 7.ITR104 Connection (4 Inputs) Fig 8.ITR102 Connection (2 Inputs) PM190207005BEN ©2019 INTERRA...
  • Page 24 THE INTERRA WEB SITE EUROPE Turkey KNX UNIVERSAL INTERFACE - PRODUCT Interra provides documentatıon support via our WWW site www.interra.com.tr This web site is used MANUAL as a means to make files and information easily Interra available to customers. Accessible by using your Cumhuriyet mah.

Table of Contents