Symbols and Safety Instructions
General Safety Instructions
Provides essential safety guidelines for installation, intended use, and electrical work.
Regulations and Water Quality
Applicable Regulations
Outlines applicable directives, regulations, and technical rules for installation.
Heating System Water Quality Requirements
Details requirements for heating system water quality to prevent corrosion and ensure longevity.
Product Description and Parts
Supplied Parts List
Lists and illustrates all items included in the product package for installation.
Indoor Unit Information
Details unit compatibility with different outdoor units and its integrated features.
Functional Principle
Explains how the heat pump system operates, including booster heater and DHW functions.
Product Overview Diagram
Provides a visual diagram of the indoor unit's components and connections.
Dimensions and Installation Preparation
Product Dimensions and Clearances
Specifies physical dimensions and required installation clearances for the indoor unit.
Connection Dimensions
Details the required pipe sizes and thread types for connections.
Preparing for Installation
Covers essential preparatory steps before physically installing the unit.
Indoor Unit Assembly Considerations
Provides guidance on selecting a suitable location and mounting the indoor unit correctly.
Installation Procedures
Transport and Storage Guidelines
Instructions for safely transporting and storing the indoor unit to prevent damage.
Insulation Requirements
Guidance on insulating pipework to prevent frost damage and heat loss.
Installation Checklist
A general checklist of recommended installation steps for the system.
Removing the Front Cover
Step-by-step instructions for safely removing the unit's front cover.
System Connections and Electrical Setup
Assembling the Drip Tray
Details on how to install the drip tray to manage condensation.
Connecting the Indoor Unit Hydraulically
Instructions for making the necessary hydraulic connections.
Filling the Heating System
Procedures for filling and purging the heating system with water.
Electrical Connection Overview
Detailed instructions for all electrical wiring and connections.
Module and Sensor Connections
Installer Module Connections
How to connect various sensors and communication lines to the installer module.
CAN-BUS Connections
Specific instructions for connecting the CAN-BUS communication cable.
EMS BUS Connections
Guidance on connecting accessories using the EMS-BUS system.
Fitting Temperature Sensors
Guidance on installing and connecting temperature sensors for accurate readings.
External Connections and Commissioning
External Connections
How to connect external inputs for control functions.
Terminals for Electrical Connections
Diagrams and descriptions of electrical terminal blocks for power supply and accessories.
Commissioning Overview
Procedures for starting up and configuring the heat pump system.
Commissioning Checklist
A step-by-step checklist to ensure all commissioning tasks are completed correctly.
Commissioning Procedures
Venting the Indoor Unit
Instructions for removing air from the heating system for optimal operation.
Adjusting Operating Pressure
How to set and maintain the correct system pressure for safe operation.
Pressure Switch and Overheating Protection
Explains the function and reset procedures for safety devices.
Function Test
Steps to verify the correct operation of all system components after installation.
Operation Modes and Temperature Checks
Operation Without Outdoor Unit
How to operate the unit using only the indoor heater.
Operating Temperatures
How to check and set optimal operating temperatures and differentials.
Maintenance Procedures
Maintenance Overview
Procedures for routine maintenance and cleaning of the unit.
Particle Filter Cleaning
Instructions for cleaning the particle filter to ensure optimal system performance.
Replacing Components
Steps for safely replacing components within the system.
Installation of Accessories
CAN-BUS Accessories
Instructions for connecting accessories via the CAN-BUS communication protocol.
EMS-BUS Accessories
Guidance on connecting accessories using the EMS-BUS system.
External Inputs
How to use external inputs for system control and monitoring.
Domestic Hot Water Cylinder Installation
Instructions for installing a DHW cylinder, including volume selection.
Accessory Connections and System Configurations
DHW Cylinder Temperature Sensor TW1
How to connect the DHW temperature sensor for accurate hot water control.
Diverter Valve VW1
Instructions for connecting the diverter valve for DHW cylinder systems.
DHW Circulation Pump PW2
Information on installing and configuring the DHW circulation pump.
Multiple Heating Circuits
Guidance on setting up multiple heating circuits with additional modules.
Swimming Pool Integration and Technical Information
Swimming Pool Installation
Specific instructions for integrating the system with a swimming pool heating system.
Environmental Protection and Disposal
Information on responsible disposal of the appliance and packaging.
Technical Specifications Overview
Detailed technical specifications and data for the indoor unit.
Specifications: Indoor Unit with Booster Heater
Electrical, heating, and pressure specifications for the unit.
System Solutions and Hydraulic Diagrams
Primary Circulation Pump Diagram (PCO)
Diagram illustrating the primary circulation pump's performance curve.
System Solutions Overview
Overview of different system configurations and required accessories.
Explanation of System Solutions
Explains the terminology and components used in various system solutions.
Bypass of the Heating System
Details on installing a bypass for systems not meeting flow or pressure requirements.
Hydraulic System Configurations
System with Booster Heater, DHW, Heating (No Bypass/Mixer)
Hydraulic diagram for a specific system configuration.
System with Booster Heater, DHW, Heating (With Bypass/Mixer)
Hydraulic diagram for another system configuration with bypass.
System with Booster Heater, Buffer, DHW, Heating
Hydraulic diagram for a system including a buffer tank.
Explanation of Hydraulic Symbols
A key to understanding the various hydraulic symbols used in diagrams.
Wiring Diagrams
Wiring Diagrams Overview
Provides electrical wiring diagrams for system components.
Installer Module Wiring Diagram
Wiring diagram for the installer module and its connections.
CAN & EMS BUS Wiring
Diagrams showing CAN and EMS BUS connections for accessories.
Wiring Diagram: 5.85kW 230V~ Booster Heater
Specific wiring diagram for a 230V~ unit.
Advanced Wiring and System Connections
Wiring Diagram: 5.85kW 3N~ Booster Heater
Wiring diagram for a 400V 3N~ unit.
Wiring Diagram: 400V 3N~ Indoor with 230V~ Outdoor
Wiring diagram for a 400V 3N~ indoor unit with a 230V~ outdoor unit.
EMS Bus Connection Alternatives
Alternative methods for connecting EMS bus components.
Photovoltaic (PV) System Connection
Information on connecting and utilizing a PV system with the heat pump.
Technical Data and Measurements
Cable Scheme Details
Table detailing cable types, sizes, and connections for various components.
Temperature Sensor Measurements
Tables showing resistance values for temperature sensors at different temperatures.

Table of Contents