alkitronic CLD 280 Operating And Maintenance Manual

Compact torque multiplier

Advertisement

CL
Operating and
maintenance manual
Compact torque multiplier
CL / RCL Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLD 280 and is the answer not in the manual?

Questions and answers

Summary of Contents for alkitronic CLD 280

  • Page 1 Operating and maintenance manual Compact torque multiplier CL / RCL Series...
  • Page 2: Table Of Contents

    Obligations of the operator maintenance instructions carefully and to observe the Intended use following points: The alkitronic® torque multiplier is only to be repaired or Operation serviced by employees of alki TECHNIK GmbH, by those Commissioning trained by alki TECHNIK GmbH or a certified service pro- Preparing for use vider.
  • Page 3: A Incoming Goods Inspection And Packaging

    3-7 bar (43-10,000 psi) at a flow rate of approx. 10-15 keep the packaging! l/sec (122-915 cu.in./min) guarantee optimum working even in explosion-protected working areas. alkitronic® CLD alkitronic® CLS2 2 gear compact torque multiplier Compact torque multiplier Torque up to approx. 7,225 Torques up to approx.
  • Page 4 Torque reaction absorber Type RCL alkitronic® STACO alkitronic® STABI Standard nut Standard connector To reduce the wrench size alkitronic® STA (4) The maintenance unit ensures a long service life thanks to the oiled operating pressure of the Support plunger alkitronic® torque multiplier (see also section E, page 11).
  • Page 5: Safety Instructions

    Torque reaction absorber If you have questions about safety measures and areas of ap- plication, your alkitronic® Partner will be happy to help you. • Place the alkitronic® CL multiplier on a flat surface • Put support foot / DMA (1) on the gearing (4) Incorrect operation, improper use, operation by • Fix the standard nut / connector (2) / (3) to the square...
  • Page 6: Torque Adjustment

    The desired air pressure can be set via the pressure regulator of the maintenance unit. The torque setting for the alkitronic® torque multiplier must be set either on the maintenance unit (appendix E) or on the air supply in accordance with the enclosed characteristic data sheet (see sample illustration on the right).
  • Page 7: Operation - Safety Measures

    (1). Due to the high strain of the alkitronic® pneumatic Before connecting the air hose, set the air pres- motors, it is necessary to ensure an adequate oil sure according to the machine type (see technical supply.
  • Page 8: Alkitronic® Cld, Cls, Cls2

    / connector (4) • A secure, stable counter support (5) must be ensured • Always hold the alkitronic® CL in axis (6) to the bolt dur- ing the process • After pressing the rocker switch (3) for clockwise rotation,...
  • Page 9: Finishing Or Interrupting The Work

    Support plunger • Interrupt compressed air supply - uncouple the com- pressed air hose at the machine • Place the alkitronic® CL on a flat surface • Remove rubber ring (6) and locking pin (7) or locking screw (8) alkitronic® STA Support plunger • Remove standard nut / connector (2) / (3) towards the...
  • Page 10: Maintenance

    DIN EN ISO 11148 6:2013-05, DIN EN ISO 15744:2008-11 In the event of prolonged periods without operation, the motor of the alkitronic® multiplier must be supplied with oil January 2019 via the connector (1) of the compressed air supply at the pis- Alexander Kipfelsberger, tol grip (Fig.
  • Page 11: Technical Data

    Pneumatic Torque Multiplier 7. Technical data CLS2 Dimensions [mm] Models CLS CLS 15 CLS 25 CLS 35 CLS 45 CLS 75 CLS 95 CLS 135 CLS 175 CLS 255 CLS 315 Type Torque range (approx.) * 75-225 95-280 135-390 165-485 305-895 365-1080 495-1450...
  • Page 12 Spare part and repair service alki TECHNIK GmbH Development, Production and Distribution of Bolting Systems Unterlettenweg 4 – 85051 Ingolstadt/Germany – fon +49 841 97499-0 – fax +49 841 97499-90 info@alkitronic.com – www.alkitronic.com EXTRACT FROM OUR PRODUCT RANGE THE ELECTRICS THE PNEUMATICS...

Table of Contents