Samsung AG056KSV Series Installation Manual
Samsung AG056KSV Series Installation Manual

Samsung AG056KSV Series Installation Manual

Dvm chiller
Table of Contents

Advertisement

Quick Links

DVM CHILLER
Installation manual
AG042KSVTTT / AG056KSVTTT / AG070KSVTTT Series
• Thank you for purchasing this Samsung Product.
• Before operating this unit, please read this manual carefully and retain it for future reference.
DB68-05916A-09_IM_DVM Chiller Outdoor_EU_EN_.indd 1
2022-05-02 오전 8:59:54

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AG056KSV Series and is the answer not in the manual?

Questions and answers

Summarization of Contents

Safety Information
For Operation
Safety precautions and warnings for operating the DVM CHILLER unit.
Preparing for Installation
Specifications of the Non-Pump Models
Technical specifications for DVM CHILLER non-pump models.
Specifications of the Pump Integrated Models
Technical specifications for DVM CHILLER pump integrated models.
DVM CHILLER Classification
Classification and appearance details of DVM CHILLER units.
Moving the Product
Guidelines and precautions for safely moving the DVM CHILLER unit.
Center Location
Recommended installation positions and dimensions for DVM CHILLER units.
Accessories (Basic Specification)
List of basic accessories supplied with the DVM CHILLER.
Field Supply
Details on field-supplied components like strainers for the DVM CHILLER.
Selecting Installation Location
Installation Guide at the Seashore
Specific guidelines for installing DVM CHILLER units near the seashore.
Required Space for Installation
Single Installation
Space requirements for installing a single DVM CHILLER unit.
Module Installation
Space requirements for installing multiple DVM CHILLER units in modules.
Base Construction and Installation
Supporting Base Construction
Requirements and methods for constructing a stable supporting base for the DVM CHILLER.
Product Installation
General procedures for installing the DVM CHILLER product.
Examples of Draining Work
Visual examples of proper drainage construction for DVM CHILLER installation.
Base Mount and Anchor Bolt Position
Specifications for mounting the base and positioning anchor bolts for the DVM CHILLER.
Installation Precautions
Important precautions to follow before and during DVM CHILLER installation.
Connecting the Anchor Bolt
Detailed instructions for connecting anchor bolts for securing the DVM CHILLER.
Anchor Specification
Technical specifications for anchor bolts used in DVM CHILLER installation.
Connecting the Pipe
Instructions for connecting pipes during the installation process.
Installing Vibration-Isolation Frame
Steps for correctly installing vibration-isolation frames for DVM CHILLER units.
Installing Discharge Duct
Guidelines for installing discharge ducts for optimal DVM CHILLER performance.
Installing the Wind/Snow Prevention Duct
Installing the Discharge Duct Around the Obstacles
Methods for installing discharge ducts to avoid obstacles near the DVM CHILLER.
Installing the Discharge Duct in Cold Regions
Specific considerations for installing discharge ducts in cold climates with snowfall.
Installing the Discharge Duct in Regions with Strong Wind
Guidelines for installing discharge ducts in areas prone to strong winds.
Water Pipe Installation
Water Pipe Diagram
Diagram illustrating the water system layout for DVM CHILLER water pipe installation.
Installation Precautions
Key precautions for installing the water pipes of the DVM CHILLER system.
Installing Strainer
Instructions for installing strainers in the water system to prevent foreign substances.
Maintaining Circulating Water Amount
Importance of maintaining adequate circulating water levels to prevent heat exchanger damage.
Drainage During Winter Time
Procedures for draining water systems to prevent freezing during winter.
Air Venting
The process of venting air from the water side heat exchanger.
Solution for Freeze Protection Device
Actions to take when the freeze protection device is activated.
Solution for Pump Vibration Noise
Methods to reduce pump vibration noise in the water system.
Maintaining Contamination
How to prevent and manage contamination in the chilled/heating water system.
Solution for Water Level Decrease
Steps to take if the water level in the system decreases.
Freeze Protection Operation
How the freeze protection system operates and precautions.
Water Flow Rate Range
Recommended minimum and maximum water flow rates for DVM CHILLER operation.
Securing Water Storage
Guidelines for ensuring adequate water storage in the DVM CHILLER system.
Minimum Water Storage
Minimum water storage requirements for DVM CHILLER operation.
Connecting Water Pipe
Instructions for connecting water pipes, including flange and bolting specifications.
Using the Pump
Startup
Procedures and precautions for starting the DVM CHILLER pump.
Checking the Direction of Rotation
How to check and ensure the correct rotation direction of the pump motor.
Maintenance
General maintenance tips for the DVM CHILLER pump motor.
Frost Protection
Measures to protect the DVM CHILLER pump from frost damage during winter.
Cleaning
Recommended cleaning procedures for the DVM CHILLER pump.
Repairing the Pump and Connecting the Pipe
Guidance on repairing the pump and connecting associated piping.
Pump Performance Chart
Performance curves (NPSH, Head, Efficiency, Power) for the DVM CHILLER pump.
Fault Finding
Troubleshooting guide for common problems encountered with the DVM CHILLER pump.
Electrical Wiring Work
Circuit Breaker and Power Cable Specification
Specifications for circuit breakers and power cables suitable for DVM CHILLER.
Power and Communication Cable Configuration
Guidelines for configuring power and communication cables for DVM CHILLER.
Specification of the Protection Tube
Details on different types of protection tubes for cables and their applications.
Connecting the Power Cable
Instructions for connecting power cables to the DVM CHILLER units.
Connecting the Communication Cable
Procedures for connecting communication cables between DVM CHILLER units and controllers.
External Contact Wiring Work
Wiring details for external contacts on the DVM CHILLER for control functions.
Output Contact
Information on the output contacts available on the DVM CHILLER for external signaling.
Input Contact
Information on input contacts for controlling DVM CHILLER functions via external signals.
Input Contact (continued)
Continued details on input contacts for DVM CHILLER functions and their recognition methods.
Input Contact (continued)
Further details on input contacts, including temperature sensor configurations and notes.
Input Contact (continued)
Final details on input contacts, including sensor specifications and an installation example.
Selecting Solderless Ring Terminal
Guide to selecting appropriate solderless ring terminals based on power cable dimensions.
Connecting the Power Terminal
Instructions for connecting power cables to the terminal board using solderless ring terminals.
Examples of Using the Cable Striper
Step-by-step guide on how to use a cable striper tool for wire preparation.
Fixing the Power Cable
Procedures for securely fixing power cables inside the DVM CHILLER's power supply box.
Fixing the Ground Cable
Instructions for properly connecting and fixing the ground cable for safety.
Withdrawing the Power Cable
How to safely withdraw power cables through protection tubes.
Grounding Work
Essential procedures and standards for performing safe grounding of the DVM CHILLER.
Installing the Solution Device
Steps for installing the Solution device, including terminal block connections.
Performing the Grounding Work
Guidance on performing grounding work using exclusive or electrical panel terminals.
Setting Key Function
Setting Hydro Controller Option
Instructions for setting various options for the hydro controller via basic segment display.
Setting Key Function (continued)
Table detailing various function settings available for the hydro controller.
Setting Key Function (continued)
Further options and settings for the hydro controller, including water law and temperature functions.
How to Set Hydro Controller Option
Step-by-step guide on how to navigate and set hydro controller options.
Setting Key Function (continued)
Table detailing various function settings available for the hydro controller.
Setting Key Function (continued)
Further options and settings for the hydro controller, including water law and temperature functions.
Function Description
Detailed descriptions of various functions and their operational logic.
MICOM Version Display
Information on displaying and checking the MICOM version of the DVM CHILLER.
Installing and Setting the Option with Tact Switch and Functions
Guide to installing and setting options using tact switches and understanding their functions.
Setting Key Operation and Checking the View Mode with Tact Switch
How to operate keys and check view modes using tact switches on the DVM CHILLER.
Setting Key Function (continued)
Detailed list of key operations for checking various parameters and settings.
Setting Key Function (continued)
Further key operations for checking version information and unit addresses.
Water Law
Outdoor Temperature Standard
How outdoor temperature influences water law settings for DVM CHILLER.
Room Temperature Standard
How room temperature influences water law settings for DVM CHILLER.
Setting Inverter Controller Option
Basic Segment Display
Display contents and segments for setting inverter controller options.
Setting Inverter Controller Option Switch
Visual guide to the inverter controller option setting switches (K1-K4).
Check Points After Installation
Installation Work
Checklist for verifying the external condition and installation of the DVM CHILLER.
Water Pipe Work
Checklist to ensure water pipe installation is correctly completed.
Electrical Wiring Work
Checklist for verifying correct electrical wiring and cable connections.
Option
Checks related to product options, including vibration isolation frames.
Trial Operation
Precautions and checks to perform before starting the trial operation of the DVM CHILLER.
Trial Operation for Each CHILLER Unit
Step-by-step trial operation procedures for individual CHILLER units.
DIP S/W
Explanation of DIP switch settings for main control and remote control modes.
Water Side Pressure Sensor Calibration
Procedure for calibrating the water side pressure sensor for accurate readings.
Set Temperature
How to adjust the set temperature for cooling and heating modes.
Set Temperature Range
Defined temperature ranges for cooling and heating operations.
Operation ON/OFF by Tact Switch
How to use tact switches for operating the DVM CHILLER on/off.
Initialize Hydro Controller
Procedure to initialize the hydro controller settings using tact switches.
Maintenance
Name of the Parts
Identification of major components and parts of the DVM CHILLER.
Water Pipe Installation
Detailed instructions for installing water pipes in the DVM CHILLER system.
Water Pipe Installation (continued)
Further guidelines and precautions for water pipe installation, including brine usage.
Caution Regarding Drainage During Winter Time
Important cautions for draining water systems to prevent damage during winter.
Air Venting
The process of venting air from the water side heat exchanger.
Water Maintenance Standard
Standards for maintaining water quality to prevent corrosion and scale accumulation.
Water Maintenance Standard (continued)
Detailed water quality standards for chilled and heating water systems.
Maintaining Plate Type Heat Exchanger
Procedures for cleaning and maintaining the plate type heat exchanger.
Stopping During Winter Time
Precautions and procedures for stopping the DVM CHILLER during winter.
Stopping for a Long Time
Steps to take when stopping the DVM CHILLER for an extended period.
Inspection for Normal Operation
Regular inspection points to ensure normal operation of the DVM CHILLER.
Chilled/Heating Water Flow Rate Range
Optimal working ranges for chilled and heating water flow rates.
Chilled Water Management
Guidelines for managing chilled water storage and flow rates, including P-Q curves.
Water Temperature Range
Specified operating temperature ranges for cooling and heating modes.
Freeze Prevention
Necessity and methods for preventing freezing in the DVM CHILLER system.
Freeze Prevention of Water Pipe
Methods for preventing freezing in water pipes, especially when draining is difficult.
Using Brine
Guidelines for using brine as an antifreeze solution in the DVM CHILLER.
Selecting Brine
Criteria for selecting appropriate brine types that do not damage the product.
Usage and Precaution of Brine
Precautions and best practices for using and maintaining brine solutions.
Type and Specification of Brine
Information on different types of brine (glycol, chloride, alcohol) and their properties.
Standard Data for Status of Anti-freeze
Data table for anti-freeze concentration and corresponding freezing points.
Performance Correction Factor According to Brine Concentration
Factors affecting cooling capacity, heating capacity, and pressure loss based on brine concentration.
Error Display
List of error codes and their descriptions for DVM CHILLER system errors.
Error Display (continued)
Continuation of error codes and descriptions for various component failures.
Error Display (continued)
Further error codes and descriptions, including fan and sensor errors.
Error History Display
How to access and view the error history of the DVM CHILLER.
Air Tightness Test and Vacuuming
Procedures for performing air tightness tests and vacuuming the refrigerant system.
Important Information Regulation Regarding the Refrigerant Used
Regulatory information concerning fluorinated greenhouse gases used in the refrigerant.
Vacuuming the Pipes
Detailed steps for vacuuming the refrigerant pipes using appropriate tools.
Troubleshooting
Common situations that are not product breakdowns but require attention.
Troubleshooting (continued)
Further troubleshooting steps for common operational issues and reporting problems.
Periodic Maintenance
Recommended checklist and schedule for periodic maintenance of DVM CHILLER components.
Periodic Maintenance (continued)
Continued periodic maintenance checklist and factors influencing maintenance frequency.
Maintaining Water System
Checks and cleaning procedures for the DVM CHILLER water system.
Checking Exterior and Noise
How to check the exterior condition and address noise issues.
Maintenance Contract
Information on obtaining professional maintenance services.
Moving and Reinstalling the Product
Contact information for moving and reinstalling the DVM CHILLER.
Quick Smart Features
Automatic Function
Overview of automatic functions like Cooling/Heating, Pump Interlock, and Auto Defrost.
Hot Water (Cool Storage) Mode
Features related to hot water and cool storage temperature control.
Quiet Function
How to operate the DVM CHILLER in quiet mode to reduce noise levels.
Demand Function
Functionality for limiting power consumption based on demand levels.
Forced Fan Function
Operation of the forced fan function for snow accumulation prevention.
Forced Pump Function
How the forced pump function operates when the product is not running.
Pump Operation Output
Details on pump operation output and electrical wiring for switches.
Connecting Module Control
Instructions for wiring module controls for the DVM CHILLER.
Remote Control Wiring
Guidelines for wiring remote control circuits, including cable specifications.
Correct Disposal of This Product
Information on the proper disposal of the product as electronic waste.

Table of Contents