Tabletop Model (AW25C/AW30C)
Tabletop Model (AW25C/AW30C) Directions for Use ............................. Pg 3
Warranty .................................................................................................. Pg 2
Features ................................................................................................... Pg 4
Responsibilities ........................................................................................ Pg 4
Special Precautions .................................................................................. Pg 4
Infection Control ...................................................................................... Pg 5
Introduction ............................................................................................. Pg 6
Electronic Generator and Water System ................................................. Pg 6
Handpiece Assembly ................................................................................ Pg 7
Electrical Requirements ........................................................................... Pg 7
Installing the Handpiece Assembly .......................................................... Pg 8
Installation and Operation ....................................................................... Pg 8
Shut Down Procedure ............................................................................ Pg 10
Troubleshooting ..................................................................................... Pg 10
Scaling Techniques ................................................................................. Pg 11
Ultrasonic Scaler Inserts ......................................................................... Pg 26
Build-In Model (AW25BI/AW30BI)
Build-In Model (AW25BI/AW30BI) Directions for Use ........................... Pg 12
Warranty .................................................................................................. Pg 2
Features ................................................................................................. Pg 13
Build-In Model Installation Guide .......................................................... Pg 14
Responsibilities ...................................................................................... Pg 17
Daily Procedures .................................................................................... Pg 17
Special Precautions ................................................................................ Pg 17
Infection Control .................................................................................... Pg 18
Introduction ........................................................................................... Pg 18
Electronic Generator and Water System ............................................... Pg 19
Handpiece Assembly .............................................................................. Pg 19
Electrical Requirements ......................................................................... Pg 20
Installation and Operation ..................................................................... Pg 20
Shut Down Procedure ............................................................................ Pg 22
Troubleshooting ..................................................................................... Pg 22
Scaling Techniques ................................................................................. Pg 23
Brief Layout of the Build-In Style AUTOSCALER® ................................... Pg 24
Ultrasonic Scaler Inserts ......................................................................... Pg 26
1
AUTOSCALER® WARRANTY INFORMATION
For All Models
Proof of purchase such as a copy of ORIGINAL BILL OF SALE must be
submitted to obtain warranty service. Warranty DOES NOT include
Shipping and Handling charges in either direction.
South East Instruments, LLC (hereafter SEI) subject to the terms and
conditions herein below expressly set forth in Paragraphs "1" through "4"
HEREBY WARRANTS that it will repair the AUTOSCALER® Ultrasonic
Scaler which proves defective by reason of improper workmanship and or
materials.
1. SIX YEAR Parts and Labor coverage on circuit boards, and TWO YEAR
Parts and Labor coverage on all other components of the
AUTOSCALER®.
2. ORIGINAL PURCHASER: This warranty is limited to the original
purchaser of the unit. When requesting warranty service, SEI needs a
RETAIL sales receipt to VALIDATE sales/installation date.
3. PROPER DELIVERY: The unit must be shipped, Freight Prepaid, or
delivered to SEI to render the services provided hereunder in either
its original package, or a similar package affording an equal degree of
protection. Warranty does not include shipping and handling back to
the customer.
4. UNAUTHORIZED REPAIR, ABUSE, ETC.: The unit must not have been
previously altered, repaired or serviced by anyone other than SEI or a
qualified technician. To render such service, the serial number on the
unit must not have been altered or removed. The unit must not have
been subjected to accident, misuse, abuse, or operated contrary to
the operating instructions. Handpiece assembly is not warranted if
subjected to abuse from excessive pulling/stretching, debris and/or
chemical accumulation from water supplies. Water system is not
warranted by failure due to debris, and/or chemical deposits from
water supplies or added medicinal solutions. Foot switch is not
warranted by failure due to tampering, or operation/storage in a wet
environment.
EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, NO OTHER
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF
MERCHANTABILITY, AND FITNESS FOR A PARTICULAR PURPOSE, SHALL AP-
PLY TO THIS EQUIPMENT. DAMAGES ARE LIMITED STRICTLY TO REPAIR OR
REPLACEMENT OF PARTS. UNDER NO CIRCUMSTANCES SHALL SEI BE LIABLE
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE
OF THE EQUIPMENT, AND SEI NEITHER ASSUMES NOR AUTHORIZES ANY
REPRESENTATIVE, OR OTHER PERSON TO ASSUME FOR IT ANY OBLIGATION
FOR LIABILITY OTHER THAN SUCH AS IS EXPRESSLY SET FORTH HEREIN.
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AW30C and is the answer not in the manual?

Questions and answers

Summary of Contents for AUTOSCALER AW30C

  • Page 1: Table Of Contents

    For All Models Tabletop Model (AW25C/AW30C) Proof of purchase such as a copy of ORIGINAL BILL OF SALE must be Tabletop Model (AW25C/AW30C) Directions for Use ......Pg 3 submitted to obtain warranty service. Warranty DOES NOT include Warranty ....................Pg 2 Shipping and Handling charges in either direction.
  • Page 2: Features

    SPECIAL PRECAUTIONS  THE AUTOSCALER® ULTRASONIC SCALER IS A PRESCRIPTION DEVICE AND IS The flexible Water Input Hose is subject to deterioration by INTENDED FOR USE ONLY BY LICENSED DENTAL PRACTITIONERS.
  • Page 3: Infection Control

     INTRODUCTION The AUTOSCALER® should NOT be used on or near anyone fitted with a CARDIAC PACEMAKER. Your South East Instruments AUTOSCALER® Ultrasonic Scaler is a  Do not remove the cover from the unit. There are NO user precision engineered instrument, constructed with the finest of serviceable parts inside.
  • Page 4: Handpiece Assembly

    The handpiece assembly is used to accept Cavitron® interchangeable NOT over tighten the lock ring, be careful not to cross thread the lock insert tips. It is connected to the AUTOSCALER® front panel by a Quick ring. Connector. The open end of the handpiece will accept all Cavitron®...
  • Page 5: Shut Down Procedure

    SPOTS (usually noted by a loud screeching sound) 2. Purge water from the AUTOSCALER® water hose and plumbing system which can affect the performance of the at the end of the day.
  • Page 6: Scaling Techniques

    NOT the enamel of the tooth ® surface. 7. If the AUTOSCALER® stops functioning or is intermittent when the handpiece cord is moved, this means a wire in the handpiece cord is broken and must be immediately repaired or replaced. DO NOT...
  • Page 7: Features

    VALVE). When the main air rheostat is pressed, an air signal is sent to the sold as component devices that require further installation by a party AUTOSCALER® console to (cavitate the insert) and the air/water block opens to appointed by the end user. If the installing technician or end user is in doubt release water flow to the handpiece.
  • Page 8 If the Scotchlok 557 connector fails to complete the AUTOSCALER® does not receive an air signal and activate. If the connection, the technician MUST so, it will permanently damage the AUTOSCALER®. Only ONE...
  • Page 9: Responsibilities

    CONDENSATION OF AMALGAM. Your South East Instruments AUTOSCALER® Ultrasonic Scaler BUILD-IN  The AUTOSCALER® should NOT be used on or near anyone fitted UNIT, is a precision engineered instrument, constructed with the finest with a CARDIAC PACEMAKER.
  • Page 10: Electronic Generator And Water System

     Two 18 gauge wires must be routed between the AUTOSCALER® of the AUTOSCALER® unit) is for adjusting the flow of water to the console and the handpiece assembly. Thinner wire may result in handpiece, and insert tip. To obtain the NECESSARY water flow of at poor tuning/operation or non function.
  • Page 11: Shut Down Procedure

    The scaler air line will bleed off to 11. The application of the power knob is for controlling the Output zero pressure protecting the AUTOSCALER®. Power to the insert tip in a smooth linear action. The operator can select the EXACT power needed for cleaning.
  • Page 12: Scaling Techniques

    NOT the enamel of the tooth surface. 6. If the AUTOSCALER® stops functioning or is intermittent when the handpiece cord is moved, this means a wire in the handpiece cord is broken and must be immediately repaired or replaced. DO NOT...
  • Page 13: Ultrasonic Scaler Inserts

    Internal water channel with plastic finger-grip The AUTOSCALER® is internally fitted from the factory with a pressure relief valve (restrictor) and must not be removed. This restrictor helps Tip Design Application relieve line pressure after each activation.
  • Page 14 INSERT STERILIZATION WATER FLOW An adequate water flow setting, indicated by a small spray or rapid drips, Sterilize inserts before each use in accordance with the insert should be selected for the power setting used to prevent overheating of manufacturer’s instructions. the insert tip during function, and to prevent possible injury.