Carer CR-P5W User Manual

Carer CR-P5W User Manual

Medical oxygen concentrator

Advertisement

Medical Oxygen
Concentrator
User's Manual
WARNING-Please read this User's Manual carefully and understand it before using the
medical oxygen concentrator.
DANGER-Fire is strictly prohibited.
CR-P3W
CR-P5W

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CR-P5W and is the answer not in the manual?

Questions and answers

Summarization of Contents

Important Safety Information
Safety Warnings and Definitions
Explains DANGER, WARNING, CAUTION, NOTE terms and important safety advice.
Symbols and Definitions
Illustrates and defines symbols used in the manual for better comprehension.
Overview and Application
Reasons for Oxygen Therapy
Discusses the reasons for choosing oxygen therapy and its benefits for patients.
Scope and Principle of Operation
Defines intended use and explains the PSA technology for oxygen generation.
Contraindications and Precautions
Lists critical warnings, contraindications, and precautions for safe operation.
Main Structure and Parts
Concentrator Components Overview
Describes the main structural parts of the medical oxygen concentrator.
Identification of Spare Parts
Lists and identifies key spare parts with numerical references for easy recognition.
Installation of Oxygen Concentrator
Placement and Clearance Requirements
Guides on selecting an appropriate location, ensuring ventilation and maintaining adequate clearance.
Nasal Oxygen Tube Recommendation
Suggests using a nasal oxygen tube exceeding 2 meters in length.
Preparation for Operation
Air Filter Maintenance
Details regular checks and cleaning of the air filter cotton for optimal performance.
Humidification Bottle and Tube Setup
Provides instructions for connecting the humidification bottle and nasal oxygen tube.
Operation Instructions
Powering On and Initial Setup
Guides on turning on the device using the power switch and starting operation.
Operational Safety Precautions
Highlights critical safety warnings, particularly concerning fire hazards and high temperatures.
Operation Settings and Timer
Adjusting Oxygen Flow Rate
Instructions on using '+' and '-' buttons to set the desired oxygen flow as per medical advice.
Understanding Cumulative Time
Explains the cumulative time display as an indicator of the unit's usage history.
Setting the Operation Timer
Details how to use the timer function to set the duration of operation.
Operation Control and Shutdown
Stopping Operation and Standby Mode
Explains how to stop the concentrator and put it into standby mode.
Powering Off and Disconnecting
Guides on safely turning off the power switch and unplugging the device when not in use.
Alarm System Details
Alarm Classification and Priority
Differentiates between high-level and medium-level alarms, including their priority.
Audible and Visual Alarm Indicators
Describes the sound patterns and visual light indicators for different alarm levels.
Alarm Response and Maintenance
Alarm Response Procedures
Outlines the steps to take when an alarm occurs, focusing on identification and action.
Humidification Bottle Cleaning
Daily cleaning procedure for the humidification bottle using boiled water.
Disposable Accessory Replacement
Recommends regular replacement of disposable items like nasal tubes and masks.
Maintenance Procedures
Air Filter Cotton Cleaning
Weekly cleaning instructions for air filter cotton, emphasizing thorough drying.
Air Intake Filter Replacement
Guidelines for replacing the air intake filter based on usage hours or environmental conditions.
Housing Cleaning
Instructions for cleaning the external casing using a damp cloth, avoiding liquid ingress.
Panel Indicators and Accessories
Control Panel Light Descriptions
Explains the function of each indicator light on the control panel (Power, Normal, Low Concentration, Service).
List of Included Accessories
Lists all accessories provided with the oxygen concentrator, including optional items.
Identifying and Removing Failures
Troubleshooting Common Failures
A checklist to help diagnose and resolve operational issues with the concentrator.
Addressing Power and Running Issues
Solutions for problems like the device not running or power indicator failures.
Resolving Filter and Alarm Issues
Troubleshooting steps for blocked filters, exhaust issues, and alarm activations.
Specifications and After-Sales Services
Model Performance and Operating Conditions
Presents key technical specs, operating conditions, and alarm parameters for the device.
Nebulizing Function and Warranty Details
Outlines nebulizing parameters and explains warranty coverage and exclusions.
Non-Warranty Conditions and Repair
Lists warranty voids and procedures for obtaining maintenance or repair services.
Environmental Protection and Graphs
Waste Disposal Compliance
Compliance requirements for the disposal of waste and residues according to national laws.
Oxygen Concentration vs. Flow Graphs
Visual representation of oxygen concentration performance against flow rate for CR-P3W and CR-P5W models.
Oxygen Concentration vs. Altitude
CR-P3W Altitude Impact Graph
Illustrates how oxygen concentration varies with altitude for the CR-P3W model at different flow rates.
CR-P5W Altitude Impact Graph
Illustrates how oxygen concentration varies with altitude for the CR-P5W model at different flow rates.
Electromagnetic Compatibility (EMC)
EMC Compliance and Usage Notes
Details compliance with EMC standards and provides notes for proper installation and use.
Electromagnetic Emission Standards
Lists emission tests and compliance levels, confirming suitability for domestic environments.
EMC Immunity Guidelines
Immunity Test Levels and Environment
Explains immunity test levels and electromagnetic environment guidelines for ESD, EFT, and Surge.
RF Immunity and Isolation
RF Immunity and Field Strength
Covers RF immunity, field strength, and recommended isolation distances from RF sources.
RF Isolation and Supplementary Instructions
Recommended RF Isolation Distances
Provides a table with calculated isolation distances based on transmitter power for RF interference prevention.
Device Classification and Features
Lists classifications like anti-shock type, protection degree, and operating mode.
Storage, Service Life, and Packing
Storage and Transportation Conditions
Specifies ambient temperature, humidity, and air pressure for storage and transportation.
Expected Service Life
States the recommended service life of the oxygen concentrator under proper use.
Contents of the Product Package
Lists all items included in the product packaging, such as the concentrator, accessories, and manual.

Table of Contents