Parts drawing #5 - Collector assembly M104C.............17 Control system - Hydraulic ..................18 Screen removal procedure ..................19 Warranty.........................20 Note : Please quote the Filter Model Number, located on the filter housing with your inquiry. FILTOMAT M100-750 Installation & maintenance – 06.2005...
The FILTOMAT® M100C series filter is a well designed, simple to install and easy-to-operate automatic water filter. The FILTOMAT will work with a range of fine screen mesh sizes from 50 to 800 micron, to suit various applications and is available with 2"& 3" BSP female inlet/outlet ports and 4” flanged.
Avoid working below lifted equipment. Wear a safety helmet when using lifting equipment. Beware of overhead electrical power lines. DIMENSIONAL INSTALLATION DRAWING NOTE: This is a conceptual installation drawing. (piping /valves etc. are not included.) FILTOMAT M100-750 Installation & maintenance – 06.2005...
Install a manual isolating valve before (upstream) the filter if there is any static head on the inlet side. If the inlet operating pressure falls below 250 kPa install a pressure sustaining valve (PSV) after the filter. NOTE: Once pressurized the filter may flush automatically, without prior warning. FILTOMAT M100-750 Installation & maintenance – 06.2005...
9. During the self-cleaning cycle, check the pressure at the filter inlet does not drop below 200 kPa, and check the pressure in the rotor chamber. NOTE: The minimum pressure in the rotor chamber should be 150 kPa lower than the inlet pressure. FILTOMAT M100-750 Installation & maintenance – 06.2005...
(1). This adjusts the rinse controller for a differential pressure of approx. 50 kPa. 5. Observe at least one automatic self-cleaning cycle, if possible, checking the differential set point with the gauge on the 3–way valve. FILTOMAT M100-750 Installation & maintenance – 06.2005...
PSV valve is fitted) maintain at least 200 kPa backpressure on the filter while doing this. Once the pipeline has been pressurised open the valve fully. Note: If in doubt, please call us for assistance. FILTOMAT M100-750 Installation & maintenance – 06.2005...
Hydraulic Control System d r a i n 1 = Green 8 mm fittings 7 = Red 6 mm fittings 3 & 5 = Black 6 mm fittings FILTOMAT M100-750 Installation & maintenance – 06.2005...
Faulty replaced parts are to be returned to Triangle Filtration for inspection and assessment, so they in turn can claim warranty replacements from the manufacturer. If you have any questions, contact your local dealer or our service department. FILTOMAT M100-750 Installation & maintenance – 06.2005...