AKOS Gemini XLG Installation Manual

Insert fireplace

Advertisement

NV70-F1
Mercury S
Mercury M
Mercury L
NV-120H-F1
Mercury XL
NV-150H-F1
Mercury XLG
Mercury XXL
NV70-F2L
Uranus Left S
Uranus Left M
Uranus Left L
NV120-F2L
Uranus Left XL
NV150H-F2-L
Uranus Left XLG
Uranus Left XXL
NV70-F2R
Uranus Right S
Uranus Right M
Uranus Right L
NV-120H-F2R
Uranus Right XL
NV-150H-F2R
Uranus Right XLG
Uranus Right XXL
AKOS Sp. z o o.
ul. Bruszewska 22, 03-046 Warszawa
NIP: 5361925006; REGON 365653140
Tel: +48881697975; email: office@akosfire.com
Insert Fireplace
Installation Manual
NV70-F3
Meridian S
Meridian M
Meridian L
NV-120H-F3
Meridian XL
NV-150H-F3
Meridian XLG
Meridian XXL
Gemini S
Gemini M
Gemini L
Gemini XL
Gemini XLG
Gemini XXL
Eros S
Eros M
Eros L
Eros XL
Eros XLG
Eros XXL
SQ-60
SQ-80
SQ-100
1 <
<
<
<

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gemini XLG and is the answer not in the manual?

Questions and answers

Summarization of Contents

Installation Requirements
The fire
Proper placement and distance from combustible materials and walls is critical.
False Chimney breast (IF applicable)
Guidelines for constructing a non-combustible false chimney breast with ventilation.
Control hatch (IF applicable)
Specifications for the placement and height of the control hatch.
Preparation and Installation instructions
Gas connection
Requirements for gas connection, pipe types, and safety taps.
Electric connection
Details on power supply, wall socket, and grounding requirements.
Preparation of the appliance
Steps for unpacking, checking gas pipes, and preparing for connection.
Installation of the flue
Guidance on making holes, pipe orientation, distances, and thermal isolation.
Placing the appliance
Placing the appliance
Instructions on positioning, leveling, and maintaining distances from combustibles.
Mounting the smoke emission outlet materials
Requirements for hole size, slope, and securing flue system parts.
Building a false chimney breast
Advice on performing a function test before construction and adhering to requirements.
Chimney breast
Materials and methods for constructing the chimney breast, including protective shields.
Frameless
Instructions for constructing the chimney breast for frameless installation.
Placing the decorative material
Imitation logs
Instructions for placing vermiculate charcoals and imitation logs on the burner.
Pebbles
Guidance on placing pebbles on the burner for aesthetic effect.
Calculation of flue system
Points of particular interest
Key considerations for flue system length, bends, and starting points.
Sample computations
Examples demonstrating how to calculate horizontal and vertical flue lengths.
Final Inspection
Gas tightness
Procedure for checking all gas connections for leaks using a detector.
Checking the burner pressure and the line-pressure
Steps to measure and verify inlet and burner pressures against specifications.
Ignition of the pilot light and the main burner
Instructions for starting the pilot and main burners and checking ignition.
Annual maintenance
Service and cleaning
Procedures for annual checks, cleaning pilot light, burner, glass, and logs.
Replace
Guidance on replacing chips/embers as needed.
Cleaning the glass
Methods for cleaning the glass, warning against fingerprints.

Table of Contents