Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Introduction for User Manual Disclaimer The Manual applies to the installation, Jolywood reserves the right to change this maintenance and use of the PV modules of installation manual without prior notice. Jolywood Jolywood Solar Technology Co., Ltd.
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module qualified personnel with specialized knowledge. the good insulation of module. Do not drop the Personnel without authorization and related module or let anything fall down onto the unit. training should not touch the photovoltaic modules...
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Only work in a dry environment, ensuring that all modules and electrical contacts are clean and dry prior to installation. If it is necessary to store the unmounted modules outdoors for a...
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Unloading Warning packaging when the project checked at the 3.2.1 site. One layer stacking for transport only allowed at project site. During transport, secure the box When unloading the modules from the...
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module 4.1.5 of double glass modules can be stacked up to 2 layers. E a c h mo d u le n e e ds to be li f t ed b y 2 people.
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module fr om t he sid e o f t h e p a c ka g e to t h e oth e r and leave the modules in the carton before side, and then carry them.
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module T h e me c h a n ic a l l o a d o f t h e Jo l y w oo components, do not damage thesurrounding components or mounting structure.
Page 10
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module JW-D60N JW-HD120N/P Four-point long-side installation Four-point long-side installation C-shaped steel parallel long side C-shaped steel parallel long side Clamp is 30mm high and 40-50mm wide Clamp is 30mm high and 40-50mm wide A=350±20mm...
Page 11
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module JW-D72N JW-HD144N/P Four-point long-side installation Four-point long-side installation C-shaped steel parallel long side C-shaped steel parallel long side Clamp is 30mm high and 40-50mm wide Clamp is 30mm high and 40-50mm wide A=450±20mm...
Page 12
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module JW-HD156N Note: The above standard installation is used in the jolywood standard Clamp. For details, please refer to the jolywood standard clamp drawing. 5.2.3 Framed Bifacial Single-Glass modules (Conventional bolt mounting)...
Page 13
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Bolt mounting method: JW-D60N JW-HD120N/P Long frame with inner four holes (990mm) for bolt Long frame with inner four holes (990mm) for mounting bolt mounting C-shaped steel parallel long side C-shaped steel parallel long side Load Pressure:front≤2400pa...
Page 14
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module JW-D72N JW-HD144N/P Long frame using inner four holes (1300mm) and Long frame using inner four holes (1300mm) central four holes (400mm) for bolt installation and central four holes (400mm) for bolt installation...
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module 5.2.4 Grounding JW-HD156N 5.2.4.1 Al l c o mpo n e n t f ra me s a n d m ou nti ng b r a c k e t s m u s t b e p r o p e r l y g r o u n d e d i n accordance with the appropriate National Electrical Code.
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module screw (together with the star washer) to the systems, be sure to check the configuration appropriate torque of 25 lbf.in. A properly of module array before wiring. sized ground wire (solid bare copper wire...
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module positive terminal of the next component. a) T h e ma xi mu m ra ti n g o f the f uses The number of components connected in connected in series with the array is typically...
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module power generation performance of the module the easy catchment area. array. 6.2.2 6.1.2 Check the electrical, grounding, and mechanical connections every 6 months to Check if the installed hardware is securely ensure that they are clean, safe, free from in place.
Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module 6.3.2.1 and fire hazard; steam cleaners are strictly prohibited; soft parts should be used when T h e o v e ra l l a ppe a r a n c e o f th e v i su al cleaning components.