Advertisement

Quick Links

Pneumatic L/N/R Series
Owner's Manual
Installation and Operating Instructions
Model:
CFM
Serial Number:
PSI
CAUTION
The final determination as to the suitability of this product for any purpose is solely that of the user.
Columbia products are not to be used to lift people or to lift anything over people.
D00097E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the N Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Columbia N Series

  • Page 1 Model: Serial Number: CAUTION The final determination as to the suitability of this product for any purpose is solely that of the user. Columbia products are not to be used to lift people or to lift anything over people. D00097E...
  • Page 2 If, after reading this manual, you have any questions regarding the installation or use of this Columbia product, contact your dealer or the Customer Service Manager of Allied Power Products, Inc. for an answer to your question.
  • Page 3: Table Of Contents

    Contents General Information ...............................4 Installation Guidelines ............................5-7 Location ................................5 Fleet Angle ................................5 Mounting ................................5-6 Pneumatic Guidelines ............................7 Wire Rope .................................7 Operation Instructions ............................8 General Maintenance .............................9-11 Troubleshooting Guide ............................12 Appendix: Parts Breakdown and/or Mounting Template (if applicable) Limited Warranty Sample Model Number H = Hoist, rated for hoisting W = Winch, rated for pulling WD2000-P-01...
  • Page 4: General Information

    Ratings and Suitability Columbia winches and hoists are not to be used to lift, pull, support or otherwise transport people or loads over people. Line pull ratings represent the maximum load that can be placed on a new unit. This load rating varies with the amount of wire rope wound on the drum and is affected by the age and condition of the unit.
  • Page 5: Installation Guidelines

    Installation Guidelines The safe installation of this product is solely dependent upon the owner and/or operator’s skill, knowledge and judgment. Installation must be done only by those qualified and familiar with all operating guidelines, safety codes and regulations related to rigging, wire rope and winch and/or hoist usage. The determination of suitability for this product for any specific use is the responsibility of the owner and/or operator.
  • Page 6 Compression-Type Mount If possible, a compression-type mount (unit on top of the mounting plate) should be used. This is the strongest and safest type of mount. There must be adequate clearance for the wire rope to pass without touching the mounting plate. Tension-Type Mount Use a tension type mount (unit below the mounting plate) when a compression mount is not possible.
  • Page 7: Pneumatic Guidelines

    Pneumatic Guidelines This Columbia unit is driven by pneumatic power. Max pressure and flow guidelines are printed on the cover of this manual. Air Supply and Circuit The air supply must be clean and relatively dry. An airline filter and lubricator should be fitted in the air supply line and located before the first control valve of the system.
  • Page 8 Anchoring Wire Rope: L Series Diagram 3 Diagram 3 Take the free end of the wire rope and insert it through the small 9/16 - 5/8 in. 7/16 - 1/2 in. opening of the anchor pocket. Loop the wire rope and push the...
  • Page 9 Incorrect Installation Diagram 6 Diagram 6 Wedge not fully seated Wedge pulled too far through anchor pocket Anchoring Wire Rope: N Series Prepare the end of the wire rope as recommended by the wire rope manufacturer. Insert the free end of the wire rope through the opening in the drum flange.
  • Page 10: Operation Instructions

    Duty Cycle All Columbia pneumatic winches and hoists are rated for continuous duty. Braking System Any time the unit is stopped, the brake will automatically engage against the load. Never leave any load unattended without properly securing it.
  • Page 11: General Maintenance

    General Maintenance Maintenance of this product is the sole responsibility of the owner and/or operator. The determination of suitability for this product for any specific use is the responsibility of the owner and/or operator. The following guidelines are to be used only as a reference. Periodically inspect the unit for general wear and tear.
  • Page 12 Gear oil changes are recommended for every 1000 hours or six (6) months of use. Use recommended type of gear oil for prevailing ambient temperature. Annual disassembly and inspection of all wear items in compliance with American National Standards Institute (ANSI) specification B30.5c 1987 and American Petroleum Institute (API) recommended practice RP 2D section 3 is recommended.
  • Page 13 HN/WN Series Diagram 4 Diagram 4 Freespool Port 1/4-18 NPTF Vent/Fill Port Drain Port 1/2-14 NPTF TYP #3 Level Port Not used HR/WR Series Diagram 5 Diagram 5 Oil Fill SAE -8 ORB Port Vent Oil Level Freespool Port Sight Gauge SAE -6 ORB Port SAE -8 ORB Port Drain Port...
  • Page 14: Troubleshooting Guide

    Troubleshooting Guide General Symptom Potential Cause 1. Inadequate air pressure/flow. 2. Air motor is not properly lubricated. 3. Air is restricted (line, mufflers, etc.) Unit will not produce line pull/line speed as listed. 4. Unit is mounted to an uneven surface. 5.
  • Page 15 NOTES...
  • Page 16 NOTES...
  • Page 17 NOTES...
  • Page 18: Limited Warranty

    All warranty claims must be submitted to APPI in writing to: Allied Power Products, Inc. 6590 SW Fallbrook Place Beaverton, OR 97008 WARNING COLUMBIA PRODUCTS ARE NOT TO BE USED FOR LIFTING PEOPLE OR THINGS OVER PEOPLE.

Table of Contents