Replacement Parts; Service Hints; Technical Service; Specifications - Desa VVC36N Series Owner's Operation And Installation Manual

Direct-vent fireplace
Table of Contents

Advertisement

REPLACEMENT PARTS

Note: Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized retailers of this product. If
they can not supply original replacement part(s),
call DESA's Customer Service Department at
1-866-672-6040.
When calling DESA, have ready
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the
factory.
PARTS NOT UNDER WARRANTY
Contact authorized retailers of this product. If
they can not supply original replacement part(s),
call DESA at 1-866-672-6040 for referral infor-
mation.
When calling DESA, have ready
• model number of your fireplace
• the replacement part number

SERVICE hINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply might be low (propane/
LP units only)
You may feel your gas pressure is too low. If so,
contact your local gas supplier.

TEChNICAL SERVICE

You may have further questions about installation,
operation or troubleshooting. If so, contact DESA's
Customer Service Department at 1-866-672-6040.
When calling, please have your model and serial
numbers of your heater ready.
You can also visit DESA's technical service web site at
www.desatech.com
116200-01F
.
www.desatech.com

SPECIFICATIONS

VC36N, VVC36N AND CGCDV36NR
• Rating: 22,400/32,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Piezo
• Manifold Pressure: 3.5" w.c.
• Minimum Inlet Supply Pressure: 5.5" w.c.
• Firebox Dimensions (HxWxD) (Flanges and
Standoffs Not Included in Measurement):
36" x 41" x 21
/
1
8
VC36P, VVC36P AND CGCDV36PR
• Rating: 20,000/28,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Piezo
• Manifold Pressure: 10.0" w.c.
• Minimum Inlet Supply Pressure: 11.0" w.c.
• Firebox Dimensions (HxWxD) (Flanges and
Standoffs Not Included in Measurement):
36" x 41" x 21
/
1
8
VC36N-HA, VVC36N-HA AND
CGCDV36NR-HA
• Rating: 22,400/32,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Piezo
• Manifold Pressure: 3.8" w.c.
• Minimum Inlet Supply Pressure: 5.5" w.c.
• Firebox Dimensions (HxWxD) (Flanges and
Standoffs Not Included in Measurement):
36" x 41" x 21
/
1
8
" (914 x 1041 x 537 mm)
" (914 x 1041 x 537 mm)
" (914 x 1041 x 537 mm)
37