Brocade 5100 Hardware Reference Manual

In this chapter

The updates in this chapter are for the Brocade 5100 Hardware Reference Manual, part number:
53-10000854-02, published July 2008.

Chapter 3, Brocade 5100 Operation

For Table 1 on page 19, replace the first row, with the LED Name Power Supply Status (right) with
the following row.
LED Name
Power Supply
Status
Fabric OS Documentation Updates
53-1002063-03
Chapter 3, Brocade 5100 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
LED Color
No light
Steady green
Flashing green
Status of Hardware
Primary power cord is disconnected
or is not actively powered, or power
supply has failed.
Power supply is operating normally.
A power supply and fan assembly
fault has occurred for one of the
following reasons:
The power supply or fan in the
assembly has failed.
The FRU was disabled by a
user.
The FRU power switch has been
turned off or the unit has been
unplugged.
Chapter
Recommended Action
Verify the power supply is on and
seated and the power cord is
connected to a functioning power
source.
No action required.
Take one of the following actions:
Replace the FRU.
Verify that the power supply/fan
assembly FRU has been
enabled.
Check the power switch and
plug.