OPERATING FIREPLACE
Continued
5. Smell for gas, including near the floor. If
you smell gas, SToP! Follow "B" in the
safety information, page 27. if you don't
smell gas, go to the next step.
6. Turn main burner wall switch to the oN
position for ignition. There will be a spark
at the electrode. The electrode is located by
the main burner.
7. replace control access panel or louver once
there is a flame at the burner.
• if burner will not stay lit after several
tries, flip wall switch to OFF and call your
service technician or gas supplier.
From Gas
Supply
Inlet
Outlet
Pressure
Pressure
Figure 58 - Electronic Control Valve
Figure 59 - Electrode
TO TURN OFF GAS
TO APPLIANCE
1. Turn off all electrical power to appliance if
service is to be performed.
2. remove control access panel or louver.
3. Close gas valve.

SPECIFICATIONS

Models (V)DVF36TCR(E) and
(V)DVF36TCL(E)
• Input Rating: 35,000/23,300 Btu/Hr
• Fuel: Natural Gas
• Manifold Pressure: 3.5" W.C.
• Minimum Supply Pressure: 4.5 W.C. **
• Maximum Supply Pressure: 10.5" W.C.
• Orifice Size (0-4500 ft.): #34 DMS
28
Models (V)DVF36TCRP(E) and
(V)DVF36TCLP(E)
• Input Rating: 31,000/20,000 Btu/Hr
• Fuel: Propane/LP Gas
• Manifold Pressure: 10.0" W.C.
• Minimum Supply Pressure: 11.0 W.C. **
• Maximum Supply Pressure: 13.0" W.C.
• Orifice Size (0-4500 ft.): #51 DMS
**For purpose of input adjustment.
When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If so,
contact your local gas supplier.
To
Main
Burner
You may have further questions about installation,
operation, or troubleshooting. If so, contact DESA's
Flame
Technical Service Department at 1-866-672-6040.
Adjustment
When calling, please have your model and serial
Knob
numbers ready.
You can also visit DESA's Technical Services web
site at www.desatech.com.
Note: Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If
they can't supply original replacement part(s)
call DESA's Technical Service Department at
1-866-672-6040 for referral information.
When calling DESA, have ready
• your name
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the
factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they
can't supply original replacement part(s) call DESA
at 1-866-672-6040 for referral information.
When calling DESA, have ready
• model number of your fireplace
• the replacement part number
www.desatech.com

SERVICE HINTS

TECHNICAL SERVICE

REPLACEMENT PARTS

• your address