To Turn Off Gas To Appliance; Manual Lighting Procedure; Optional Remote Operation - Vanguard FLAME-MAX VYM27PR Owner's Operation And Installation Manual

Unvented (vent-free) propane/lp gas log heater
Table of Contents

Advertisement

OPERATING
HEATER
Continued
8. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out
when released, contact a qualified
service person or gas supplier for
repairs.
Note: If pilot goes out, repeat steps
4 through 8.
9. Slightly push in and turn control
knob counterclockwise
ON position.
10. Wait one minute and switch selector
switch to the ON position to light
burner. Note: AUTO is only func-
tional when using GWMT1 or
GWMS2 optional accessories.
11. Set flame adjustment knob to any
level between HI and LO.
CAUTION: Do not try to adjust
heating levels by using the
manual shutoff valve.
WARNING: Make sure the
selector switch is in the OFF po-
sition when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.
Pilot Burner
Figure 22 - Pilot
104675
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Re-
mote: Set selector switch in the OFF
position to prevent draining battery.
Shutting Off Burner Only (pilot
stays lit)
You may shut off the burner and keep the
pilot lit by doing one of the following:
to the
1. Turn control knob clockwise
to the PILOT position.
2. Use remote control manual OFF
button.
3.
Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Light-
ing Instructions, page 14.
2. Depress control knob and light pilot
with match.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 9 through 11, column 1.
OPTIONAL REMOTE
Note: All remote control accessories must
be purchased separately (see Accessories,
page 24). Follow instructions included
Ignitor
with the remote control.
Electrode
Thermostat Control Operation
(Optional GHRCT Only) The thermo-
stat control setting on the remote control
unit can be set to any comfort level be-
tween HI and LO. The burner will turn
on and off automatically to maintain the
comfort level you select. The ideal com-
fort setting will vary by household de-
pending upon the amount of space to be
heated, the output of the central heating
system, etc.
OWNER'S MANUAL
OPERATION
15
For wall thermostat operation, follow in-
structions supplied with thermostat acces-
sory GWMT1. For wall switch operation
follow instructions supplied with GWMS2.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions on page 14.
1.
After lighting, let pilot flame burn for
about one minute. Turn control knob
to ON position. Adjust flame adjust-
ment knob anywhere between HI
and LO. Slide the selector switch to
the REMOTE position. NOTE: The
burner may light if hand-held remote
ON button was on when selector
switch was last turned off. You can
now turn the burner on and off with
the hand-held remote control unit.
IMPORTANT: Do not leave the se-
lector switch in the REMOTE posi-
tion when the pilot is not lit. This will
drain the battery.
IMPORTANT: Be sure to press the
ON/OFF buttons on the hand held
remote control unit for up to 3 sec-
onds to assure proper operation.
GHRC Operation:
2a. Press the ON/OFF button to turn the
burner on and off. When turning
burner off, the pilot will remain lit.
GHRCT Operation
2b. Select the MAN (manual) or AUTO
button on the hand-held remote con-
trol unit (see Figure 24, page 16)
• In manual mode, turn burner on
or off by pressing the ON or OFF
buttons on the hand-held remote
control unit.
• In auto mode, the room tempera-
ture is controlled by the thermo-
stat in the hand-held remote con-
trol unit. To increase the room tem-
perature, press the top arrow of the
TEMP button. To lower room the
temperature, press the bottom ar-
row of the TEMP button. At higher
settings the heater will run more.
Continued

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save Article as PDF