Advertisement

Please read this manual carefully before installation.
This appliance is filled with R32.
Keep this operation manual for future reference.
0011511008
条形码绘制区
ROOM AIR CONDITIONER
INSTALLATION MANUAL
1U26MACFRA
1U09MACFRA
1U35MACFRA
1U12MACFRA
1U18RACFRA
1U53RACFRA
1U71RACFRA
1U24RACFRA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1U53RACFRA and is the answer not in the manual?

Questions and answers

Summarization of Contents

General Safety Warnings
Installation, Electrical, and Refrigerant Safety
Covers professional installation, electrical work, grounding, refrigerant handling, and fire prevention measures.
Important Information & Cautions
R32 Refrigerant & DRED Appliance Details
Provides crucial information on R32 refrigerant properties and DRED appliance usage guidelines.
Handling, Storage, and Installation Basics
Loading, Transport, Storage, and Installation Rules
Details requirements for handling, transporting, storing units, and essential installation precautions.
Safety and Inspection Procedures
Safety Awareness, Unpacking, and Environment Checks
Covers safety principles, unpacking inspection, installation environment checks, and fire control measures.
Installation Requirements and Qualifications
Electrical Safety, Installer Qualifications, and Unit Installation
Addresses electrical safety, installer certification, and specific steps for indoor and outdoor unit installation.
Outdoor Unit Installation and Testing
Fixation, Vacuumizing, Leak Detection, and Post-Installation Checks
Details outdoor unit mounting, vacuumizing, leak detection, and crucial post-installation inspection and test run procedures.
Relocation and Maintenance Guidelines
Relocation Procedures and Maintenance Precautions
Outlines steps for relocating units and essential precautions for maintenance personnel and procedures.
Maintenance Environment and Leak Detection
Maintenance Site Requirements and Leak Detection Methods
Specifies requirements for maintenance sites, environmental checks, and detailed methods for detecting refrigerant leaks.
Maintenance Procedures and Components
System Preparation, Component Care, and Safety Elements
Covers system preparation, maintenance of electrical and intrinsically safe components, and refrigerant handling requirements.
Refrigerant Handling and Disposal
Removal, Charging, Storage, and Scrapping of Refrigerant
Details procedures for refrigerant removal, vacuumizing, charging, storage, and safe scrapping of units.
Refrigerant Recovery Process
Recovery Equipment and Procedures
Explains the process of recovering refrigerant, including equipment requirements and safe handling during transport.
Installation Drawings and Dimensions
Unit Placement and Fixing Diagrams
Provides visual guides for indoor/outdoor unit placement, piping, and outdoor unit fixing dimensions.
General Safety Precautions
Installation, Handling, and Unit Safety
Highlights critical safety measures for unit installation, handling, electrical connections, and refrigerant usage.
R32 Refrigerant Safety Guidelines
Piping, Tool Use, and Environment Safety for R32
Focuses on safety precautions specific to R32, including piping, tool compatibility, and environmental considerations.
Operational and Wiring Safety
Precautions for Operation, Wiring, and Installation
Covers immediate actions for issues, prohibited practices, installation site risks, and essential electrical wiring safety.
Pre-Test Run and Electrical Safety
Pre-Installation, Wiring, and Test Run Safety
Details safety measures for grounding, wiring, unit placement, disposal, and critical steps before and after test runs.
Pre-Installation Checks and Tools
Verification, Cautions, and Necessary Tools for R32
Lists essential checks, cautions, and specific tools required for installing R32 units, including those not to be used.
Piping Material Specifications
Copper Pipe, Flare Machining, and Flare Nut Standards
Details specifications for copper pipes, flare machining dimensions, and flare nut types for R32 units.
Air Tightness, Vacuuming, and Charging
Test Procedures and Refrigerant Handling for R32
Explains air tightness testing, vacuuming procedures, refrigerant charging methods for R32, and leak remedies.
Outdoor Unit Installation Steps
Site Selection, Mounting, and Dimensions
Covers selecting installation sites, mounting the outdoor unit securely, and provides installation dimension details.
Piping Connection and Sizing
Pipe Sizes, Connection Methods, and Extended Pipe Rules
Details pipe sizing, connection procedures, fastening torques, and guidelines for charging refrigerant with extended pipes.
Air Tightness Testing
Nitrogen Pressure Testing and Leak Identification
Describes the process of conducting air tightness tests using nitrogen and methods for identifying leakage points.
Piping Vacuuming Procedure
Vacuum Pump Use and Leak Check
Explains how to connect and use a vacuum pump, perform leak checks, and handle refrigerant if leaks are detected.
Electrical Wiring Procedure
Wiring Precautions, Size Selection, and Connection Steps
Covers essential wiring precautions, selecting appropriate wire sizes, and step-by-step connection procedures.
Outdoor Unit Troubleshooting
Fault Diagnosis and Analysis
Provides a guide to identify and diagnose common operational faults based on LED indicators and system behavior.