Heidelberg Retina Angiograph 2
HRA 2
Operation Manual
Revision 1.1-1E, March 2003
©Heidelberg Engineering GmbH
Printed in Germany
Technical Specifications are Subject to change without notice
Art.No. 97 039-002
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HRA 2 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction to Heidelberg Retina Angiograph 2
Intended Use of the Device
Defines the primary purpose and application of the device for eye examination.
Heidelberg Retina Angiograph 2 Overview
Describes the confocal laser scanning system and its capabilities.
Safety Information and Precautions
Contraindications for Use
Lists conditions or situations where the device should not be used.
Important Warnings for Operation
Highlights potential hazards and critical precautions for safe operation.
Precautions for Safe Operation
Details necessary measures to prevent harm or ensure proper function.
Installation and Setup Procedures
Instrument Components Overview
Lists and describes the main parts of the HRA2 system.
Scope of Delivery Details
Details all items included in the instrument package.
Installation Procedure Guide
Provides step-by-step instructions for setting up the instrument.
Safety and Maintenance Guidelines
Instrument Safety Guidelines
Covers crucial safety guidelines and procedures for using the instrument.
Instrument Care Instructions
Instructions for maintaining the instrument's condition.
General Operating Information
Turning Instrument On and Off
Procedures for powering the Heidelberg Retina Angiograph 2 on and off.
Controls Overview
Describes the various control elements of the HRA2 system.
Touch Panel Screens Explained
Explains different screens like Main Screen and Target Select Screen.
Acquisition Mode Screen
Explains how to select different image acquisition modes.
Advanced Controls and Operations
Time Series Setup
Details how to set the duration for time-series acquisitions.
Depth and Frame Sequence Settings
Covers setting scan depth for Z-Sequence and frames for M-Sequence.
Injection Timer and More Screen
Describes injection button function and accessing the More screen.
Foot Switch Operation
Explains the function of the foot switch for acquiring images.
Physical Controls and Adjustments
Keyboard and Mouse Usage
Details how to use the keyboard and mouse for software control.
Focus Knob Adjustment
Describes how to adjust the focus knob for clear image acquisition.
Filter Lever Operation
Explains how to use the filter lever to select angiography or reflectance modes.
Sensitivity Knob Adjustment
Details how to adjust the camera's light sensitivity for optimal brightness.
Image Acquisition Process
Patient and Instrument Preparation
Outlines necessary preparation steps for the patient and instrument.
Acquiring Images
Details the step-by-step process for acquiring images with the HRA2.
Creating Patient Records and Examinations
Guides on creating new patient records and examinations in the software.
Touch Panel Settings and Patient Alignment
Explains touch panel settings and patient positioning for image acquisition.
Image Acquisition Details
Displaying and Changing Acquisition Parameters
Describes how to view and modify acquisition parameters during the process.
Acquiring Images Step-by-Step
Provides detailed steps for capturing images, including reflectance and FA modes.
Image Acquisition Setup Functions
Details setup functions for scan parameters and injection timers.
Scan Parameter Setup
Explains how to configure default scan resolution and cyclic buffer size.
Image Inspection and Analysis
Image Viewing Procedures
Describes how to view images in the Heidelberg Eye Explorer database.
Image Display and Tools
Covers displaying images, using overlay tools, and zooming functions.
Image Enhancement Techniques
Explains how to adjust contrast, brightness, sharpen, and reduce noise.
Movie Display and Playback
Details how to play back and view movie sequences.
Image Processing and Printing
Expanding a Movie
Describes how to extract single images from a movie object.
Image Processing Procedures
Covers processing acquired images, including composite and mean images.
Eye Movement Correction
Explains how to compute and apply eye movement correction to movies.
Printing Acquired Images
Details how to print acquired images using an attached printer.
Technical Data and Specifications
Printing Options
Covers selecting printers and customizing print reports and layouts.
Model and Manufacturer
Identifies the device model and its manufacturer details.
Environmental Specifications
Lists operating and non-operating temperature and humidity ranges.
Power Supply and Fuses
Specifies voltage, frequency, and fuse requirements for the system.
System Specifications
Isolation Transformer Requirements
Details certification requirements for isolation transformers used with PC components.
Laser Source Specifications
Lists laser types, wavelengths, and class for ICG excitation, IR, and FA.
Scanning Specifications
Provides detailed scanning parameters for High Resolution and High Speed modes.
PC Requirements
Lists hardware and software specifications for the PC used with the HRA2.
Service, Labels, and Disposal
Service, Maintenance, and Cleaning
Outlines service, maintenance, and cleaning procedures for the instrument.
Labels and Markings
Identifies various labels and serial numbers on the instrument components.
Disposal Procedures
Specifies that only Heidelberg Engineering shall dispose of the device.

Table of Contents