FIREPLACE INSTALLATION
Continued
3. Activate the remote handset battery by removing the insulating
tab on the back of the handset (see Figure 46). The battery is
included pre-installed.
4. Once the battery is activated the unit is ready to use.
5. Close lower louver panel.
INCOMING MAIN
GAS SUPPLY
EV1
EV2
GAS LINE TO
BURNER
111924-01D
WIRING DIAGRAM
Pilot
Burner
Pilot Gas
Line
24V AC
STEP DOWN
TRANSFORMER
120V AC
www.desatech.com
Battery Cover
12 Volt Battery
Back of
Handset
Figure 46 - Installing Battery into Back of Handset
WALL SWITCH
(SUPPLIED)
ELECTRICAL RATING:
120v, 60Hz, 0.7A
OPTIONAL
REMOTE
CONTROL
Pull to Remove
Insulation Tab
BLACK
INCOMING
120V AC
WHITE
(FUSE BOX
GREEN
OR BREAKER)
21