Vanguard VP10TA Owner's Operation And Installation Manual page 11

Infrared vent-free propane/lp gas heater
Table of Contents

Advertisement

OPERATING
HEATER
Continued
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information
on page 10, column 3.
2. Make sure equipment shutoff valve
is fully open.
3. Turn control knob clockwise
to the OFF position.
4.
Wait five (5) minutes to clear out any
gas. Then smell for gas, including near
the floor. If you smell gas, STOP! Fol-
low "B" in the safety information on
page 10, column 3. If you don't smell
gas, go to the next step.
5. Press in control knob, and turn coun-
terclockwise
Keep control knob pressed for five
seconds.
Note: You may be running this
heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up
when released, contact a qualified
service person or gas supplier for
repairs.
6. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the bottom of burner. The pilot can
be seen below the left hand plaque.
If needed, keep pressing ignitor but-
ton until pilot lights.
• If pilot does not stay lit, contact a
qualified service person or gas sup-
plier for repairs.
Ignitor Button
Control Knob
IGNITOR
Figure 16 - Control Knob In The OFF
Position
104083
7.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note: If pilot does not light, repeat
steps 3 through 7. This heater has a
safety interlock system. Wait one (1)
minute before lighting pilot again.
8.
Turn control knob counterclockwise
plaques should light. Set control
knob to any heat level between HI
and LO.
Thermocouple
to pilot position.
Figure 17 - Pilot
heating levels by using the equip-
ment shutoff valve.
The control knob can be set to any heat
level between HI and LO. When the room
temperature exceeds the set temperature,
the burner will cycle to pilot. The burner
will cycle back on when room tempera-
ture drops below the set temperature.
Note: The thermostat sensing bulb mea-
sures the temperature of air near the
heater cabinet. This may not always agree
with room temperature (depending on
housing construction, installation loca-
tion, room size, open air temperatures,
etc.) Frequent use of your heater will let
you determine your own comfort levels.
OWNER'S MANUAL
to desired heating level. Both
Ignitor
Pilot Burner
Electrode
CAUTION: Do not try to adjust
THERMOSTAT
CONTROL
OPERATION
11
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise
the OFF position.
Shutting Off Burner Only (pilot
stays lit)
Turn control knob clockwise
the PILOT position.
MANUAL LIGHTING
PROCEDURE
1.
Remove front panel (see Figure 10,
page 8).
2.
Follow steps 1 through 5 under Light-
ing Instructions.
3.
With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.
4.
Keep control knob pressed in for 10
seconds after pilot is lit. After 10 sec-
onds, release control knob. Follow
step 8 under Lighting Instructions.
5.
Replace front panel.
to
to

Hide quick links:

Advertisement

Table of Contents
loading