Fisher Scientific 2150 Instruction And Operation Manual

Fisher Scientific 2150 Instruction And Operation Manual

Isotemp immersion circulators

Advertisement

sales@artisantg.com
artisantg.com
(217) 352-9330 |
|
Click HERE
Find the Fisher Scientific Isotemp 2150 at our website:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2150 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fisher Scientific 2150

  • Page 1 (217) 352-9330 | Click HERE Find the Fisher Scientific Isotemp 2150 at our website:...
  • Page 2 Isotemp Immersion Circulators Manual P/N U00438 Rev. 08/11/05 Instruction and Operation Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3: Table Of Contents

    Safety Features .......... 6 2150 Unique Operation Controller ............ 7 Maintenance & Troubleshooting Cleaning ............. 9 Algae ............9 Checklist 2100/2150 ........9 Checklist 2150 ..........9 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 4: Compliance

    Warranty The Isotemp circulators distributed by Fisher Scientific ("Fisher"), Fisher warrants to the direct purchaser that the product will be free from defects in material or workmanship for a period of two years from the date of delivery. Fisher will repair or replace the product or provide credit, as its sole option, upon prompt notification and compliance with its instructions.
  • Page 5: Warnings

    Warnings Make sure you read and understand all instructions and safety precautions listed in this manual before installing or operating your unit. If you have any questions concerning the operation of your unit or the information in this manual, contact our Sales Department. Performance of installation, operation, or maintenance procedures other than those described in this manual may result in a hazardous situation and may void the manufacturer’s warranty.
  • Page 6: General Information

    Description The Isotemp Immersion Circulators are used to provide precise temperature control. The unit consists of a circulating pump, heater, temperature sensor, controller and a mounting device. Specifications Model 2100 2150 Temperature Range 25°C to 100°C 25°C to 200°C Analog...
  • Page 7: Site

    Operation Site Never place the unit in an area of high humidity, or corrosive or dusty atmosphere. See specifications on page 3. Assembly Attach the supplied mounting bracket to the unit. Remove the set of screws and spacers on the rear of the unit then attach the bracket using these screws. Secure the unit to the tank using the bracket.
  • Page 8: Start Up

    Start Up Place the I/O switch to the I position. 2100 The ON LED will illuminate and the heating LED will illuminate as needed. 2150 The °C display will run a self-test, then press the start/reset button and the °C display, after a brief self-test, will indicate the temperature of the fluid near the unit's control sensor.
  • Page 9: Safety Features

    All units have a High Temperature Cutout (HTC). If the HTC temperature limit is exceeded the unit will shut down and, on 2100 units, the fault light will illuminate. On 2150 units, an alarm will sound and a fault message will be displayed.
  • Page 10: 2150 Unique Operation

    2150 Unique Operation Menu display Temperature/ Setpoint °C display ° C Heating control Enter Menu selection Value arrows Start/Reset Mains switch Controller Displaying the software version Depress and hold any key and turn the unit on. The operating software version number (e.g. n 1.5) is displayed.
  • Page 11 Correction factor cS The °C display shows the actual temperature at the unit's control sensor ±0.1°C. This temperature does not correspond directly to the temperature in the circulator’s bath and even less to the temperature of any external connected system. The temperature difference is determined by measuring the actual current temperature using a suitable measuring device (calibrated or gauged thermometer).
  • Page 12: Maintenance & Troubleshooting

    Do not use steel wool. It is abrasive and will lead to rusting. Algae We recommend the use of Chloramine-T, 1 gram per 3.5 liters. Checklist 2100/2150 Unit will not start. Check for fault conditions. Unit made need a reset.
  • Page 13 Release the keys as soon as you see P CODE shown on the °C display. The microprocessor is now reset to its basic default settings. All other parameters must now be reentered. Fault Displays If a fault occurs an alarm will sound and the °C display will indicate the fault condition. The heating element and pump will automatically shut down.