Warranty The Isotemp circulators distributed by Fisher Scientific ("Fisher"), Fisher warrants to the direct purchaser that the product will be free from defects in material or workmanship for a period of two years from the date of delivery. Fisher will repair or replace the product or provide credit, as its sole option, upon prompt notification and compliance with its instructions.
Warnings Make sure you read and understand all instructions and safety precautions listed in this manual before installing or operating your unit. If you have any questions concerning the operation of your unit or the information in this manual, contact our Sales Department. Performance of installation, operation, or maintenance procedures other than those described in this manual may result in a hazardous situation and may void the manufacturer’s warranty.
Description The Isotemp Immersion Circulators are used to provide precise temperature control. The unit consists of a circulating pump, heater, temperature sensor, controller and a mounting device. Specifications Model 2100 2150 Temperature Range 25°C to 100°C 25°C to 200°C Analog...
Operation Site Never place the unit in an area of high humidity, or corrosive or dusty atmosphere. See specifications on page 3. Assembly Attach the supplied mounting bracket to the unit. Remove the set of screws and spacers on the rear of the unit then attach the bracket using these screws. Secure the unit to the tank using the bracket.
Start Up Place the I/O switch to the I position. 2100 The ON LED will illuminate and the heating LED will illuminate as needed. 2150 The °C display will run a self-test, then press the start/reset button and the °C display, after a brief self-test, will indicate the temperature of the fluid near the unit's control sensor.
All units have a High Temperature Cutout (HTC). If the HTC temperature limit is exceeded the unit will shut down and, on 2100 units, the fault light will illuminate. On 2150 units, an alarm will sound and a fault message will be displayed.
2150 Unique Operation Menu display Temperature/ Setpoint °C display ° C Heating control Enter Menu selection Value arrows Start/Reset Mains switch Controller Displaying the software version Depress and hold any key and turn the unit on. The operating software version number (e.g. n 1.5) is displayed.
Page 11
Correction factor cS The °C display shows the actual temperature at the unit's control sensor ±0.1°C. This temperature does not correspond directly to the temperature in the circulator’s bath and even less to the temperature of any external connected system. The temperature difference is determined by measuring the actual current temperature using a suitable measuring device (calibrated or gauged thermometer).
Do not use steel wool. It is abrasive and will lead to rusting. Algae We recommend the use of Chloramine-T, 1 gram per 3.5 liters. Checklist 2100/2150 Unit will not start. Check for fault conditions. Unit made need a reset.
Page 13
Release the keys as soon as you see P CODE shown on the °C display. The microprocessor is now reset to its basic default settings. All other parameters must now be reentered. Fault Displays If a fault occurs an alarm will sound and the °C display will indicate the fault condition. The heating element and pump will automatically shut down.