INTRODUCTION
What is the TK_S014 (RTU A08)?
Defines the TK_S014 (RTU A08) as a single door controller managing readers, inputs, and outputs.
RTU A08 with Temaline Devices
Explains how the RTU A08 integrates with other Temaline devices to form a TemaKey.
Phased-out Device Compositions
Lists past device compositions for maintenance reference, including phase-out components.
RELATED DOCUMENTATION
EBI Temaline Configuration Guide
Provides further information on EBI Tema system, commissioning, and configuration.
Temaline Harsh Environment Installation
A whitepaper detailing Temaline system rules for installation in harsh environments.
PREPARING FOR INSTALLATION
Contents of the Kit
Lists the components included in the RTU A08 device shipment and support kit.
Mounting Tools Required
Specifies the required screwdrivers for the installation of the RTU A08 device.
System Architecture Overview
Illustrates a typical system architecture showing the RTU-A08 integrated with TemaServer and TemaPower.
WIRING CHARACTERISTICS
Power Supply Wire Sizing
Details power supply wire sizing based on voltage drop and cable length for the RTU.
LONWORKS® Data Cable Requirements
Specifies requirements for LONWORKS® data cable length and capacity for bus and free topology.
INPUT AND READER WIRING
Input Wire Specifications
Provides wire gauges and maximum distances for input connections, including shielding requirements.
Reader Wire Specifications
Refers to reader technical specifications for wires used to connect RTU-A08 to readers.
MOUNTING THE DEVICE
DIN/Omega Rail Mounting
Provides step-by-step instructions for mounting the RTU-A08 onto a standard DIN/omega rail.
Enclosure Mounting Guidelines
Details enclosure size requirements when mounting the RTU-A08 into a small enclosure.
CLOSING THE RTUA08 MODULE
Module Cover Securing
Instructions for clipping the cover onto the module and securing it with self-tapping screws.
WIRING OPERATION
Elemental Detail of Board
Shows a detailed view of the electronic board with positions of connectors and service elements.
Power Supply Cable Connection
Guides on connecting the 12V DC power supply to the RTU A08 device, referencing cable sizing.
LONWORKS Cable Connection
Explains how to connect LONWORKS® data cables for TemaServer communication.
LONWORKS TOPOLOGIES
Daisy Chain (BUS) Connection
Details the daisy chain (Bus) configuration for LONWORKS® data cables, including terminators.
Free Topology (STAR) Connection
Describes the free topology (Star) configuration for LONWORKS® data cables, including terminators.
READER CABLE CONNECTIONS
Lonwork Cable Connection Details
Explains connecting twisted pair cable to LON-A and LON-B, noting polarity is not significant.
Shielded Reader Cable Installation
Instructions for connecting shielded reader cables to the RTUA08 terminal screws and grounding shields.
CONNECTING THE DOOR
Internal Power Supply Door Connection
Illustrates wiring for door electro-locks using the RTU-A08's internal +14V power supply.
External Power Supply Door Connection
Details wiring for door electro-locks using an external isolated power supply (10-28VDC).
SETTING OUTPUT NORMALIY
Output Normality Configuration via Jumpers
Explains how jumpers JP1 and JP2 set the output normality (Normally Open/Closed) for OUT1 and OUT2.
HARSH ENVIRONMENT INSTALLATION
General Rules for Harsh Environments
Applies rules for cable routing, voltage separation, and distance from electromagnetic sources.
Cables Rules for Harsh Environments
Details shielding and grounding requirements for input, output, power, LON, and Wiegand cables.
ACTIVATION AND INFORMATION
Checking RTUA08-TemaServer Communication
Procedure to verify RTU A08 communication with TemaServer using the service pin and LED.
Collecting Device Identification Information
Instructions on collecting and applying bar code labels for RTU configuration in EBI Temaline.
TECHNICAL DATA
Power Supply and Weight Specifications
Details DC power supply requirements, operating current, and device weight.
Wiring and Input Specifications
Covers LONWORKS connection, controlled inputs, and Wiegand input specifications.
OUTPUT SPECIFICATIONS
LED, Buzzer, and General Output Details
Provides specifications for outputs controlling LEDs, buzzers, and general output types.
REGULATION COMPLIANCE
CE Compliance Details
Lists directives and standards the product complies with for European Union market.
FCC Radio Interference Notice
Provides FCC compliance statement and guidance for handling radio frequency interference.
UL Listing for North America
Confirms UL listing for Canada and the United States, referencing the UL60950 regulation.
ENVIRONMENTAL COMPLIANCE
RoHS Compliance Statement
States compliance with the European Parliament and Council Directive on Hazardous Substances.
WEEE Waste Directive Compliance
Details Honeywell's commitment to collection, treatment, and disposal of waste electrical apparatus.
China RoHS Environmental Protection Period
States compliance with China RoHS, indicating the environmental protection use period.
GRAPHICAL SYMBOLS MEANING
Symbols on Product and Packaging
Lists graphical symbols used on the product and packaging, with their meanings and locations.