Page 1
"A" SERIES A12 JE A15 JE A12 JED A15 JED A17 JE USE AND MAINTENANCE MANUAL - ENGLISH - ORIGINAL INSTRUCTIONS AIRO is a division of TIGIEFFE SRL Via Villa Superiore, 82 - 42045 Luzzara (RE) ITALY- +39-0522-977365 - ...
Page 2
05-2018 • Changed Name and Surname of CEO. • Unified First and Second Part. • Added “AIRO SENTINEL” secondary safety system description; • “Tilt alarm” description updated; • “ZC” warning light description (drive controller alarm) updated; 12-2018 •...
Contents: INTRODUCTION ............................6 1.1. Legal aspects ................................6 1.1.1. Delivery of the machine ............................... 6 1.1.2. Declaration of commissioning, first check, further periodical checks and transfers of ownership ........ 6 1.1.2.1. Declaration of commissioning and first check ......................6 1.1.2.2.
Page 4
Danger red warning light (ZD) ............................ 41 5.1.3.4.5. Overload red warning light (ZE) ..........................41 5.1.4. “AIRO SENTINEL” Anti-Trapping System - OPTIONAL .................... 42 5.1.4.1. SENTINEL logic movements ............................. 43 5.2. Ground control panel and electric control unit ..................... 44 5.2.1.
Page 5
7.2.7.1. Pressure relief valve of proportional movement circuit ....................65 7.2.7.2. Pressure relief valve of ON-OFF movement circuit ....................66 7.2.8. Operation check of the turret inclinometer ......................... 67 7.2.9. Adjustment of the overload controller (load cell) ......................69 7.2.10. Overload controller by-pass –...
Therefore, the description of their components, as well as control and safety systems, may include parts not present on Your machine since supplied on request or not available. In order to keep pace with the technical development AIRO-Tigieffe s.r.l.
1.1.2.2. Further periodical checks Yearly checks are compulsory. In Italy the Aerial Platform owner must apply for a periodical check - by registered letter - to the local competent inspection board (ASL/USL or other qualified public or private services) at least twenty days before the expiry of the year from the last check.
Do not use the machine for purposes other than those for which it was designed, except after making a request and having obtained written permission in this sense from the manufacturer 1.3.1. Leaving at height The work elevating platforms are not designed by taking into account the risks of the “leaving at height” because the only access position considered is when the platform is completely lowered.
1.5. Control panels The machine is equipped with two control panels: on the platform for normal use of the machine. ▪ On the turret (or on the ground) you can find the emergency controls to lower or stop the machine in emergency situations, ▪...
1.8. Identification In order to identify the machine, when spare parts and service are required, always mention the information given in the serial number plate. Should this plate (as well as the various stickers applied on the machine) be lost or illegible, it is to be replaced as soon as possible.
TECHNICAL FEATURES OF STANDARD MACHINES THE TECHNICAL FEATURES OF THE PRODUCTS IN THE FOLLOWING PAGES CAN BE MODIFIED WITHOUT PRIOR NOTICE 2.1. Model A12 JE A12 JE Dimensions: Maximum working height 12.1 39’ 8” Max. platform height 10.1 33’ 1” Ground clearance (with pot-hole guards lifted) 4’...
Page 13
Battery power Voltage and standard battery capacity - Deep Cycle 48 / 320 V/Ah 48/320 V/Ah Total electrolyte quantity of standard battery 8 x 11,4 8 x 3 Standard battery weight 8 x 52 8 x 115 Voltage and optional battery capacity 1 - Drive Battery V/Ah 48 / V/Ah...
Page 14
Use and Maintenance Manual – A12 JE A15 JE A17 JE A12 JED A15 JED Series Page 14...
2.2. Model A15 JE A15 JE Dimensions: Maximum working height 15.0 49’ 2” Max. platform height 13.0 42’ 7” Ground clearance (with pot-hole guards lifted) 5’ 3” Ground clearance (with pot-hole guards lowered) 0’ 9” Max. outreach from turntable centre 8.95 29’...
Page 16
Battery power Voltage and standard battery capacity - Deep Cycle 48 / 320 48 / 320 V/Ah V/Ah Total electrolyte quantity of standard battery 8 x 11,4 2 x 3 Standard battery weight 8 x 52 8 x 115 Voltage and optional battery capacity 1 - Drive Battery 48 / 330 48 / 330 V/Ah...
Page 17
Use and Maintenance Manual – A12 JE A15 JE A17 JE A12 JED A15 JED Series Page 17...
2.3. Model A17 JE. A17 JE Dimensions: Maximum working height 17,1 56‘ 2” Max. platform height 15,1 49‘ 5” Ground clearance (with pot-hole guards lifted) 5‘ 3” Ground clearance - with pot-hole guards down - machine with fixed 2” Ground clearance - with pot-hole guards down - machine with 1”...
Page 19
Performance: Driving wheels Max. drive speed km/h Safety drive speed km/h Oil tank capacity Gradeability Max. operating temperature °C °F Min. operating temperature °C °F Battery power Standard battery voltage and capacity - drive battery 48 / 385 48 / 385 V/Ah V/Ah Total electrolyte quantity of standard battery...
Page 20
Use and Maintenance Manual – A12 JE A15 JE A17 JE A12 JED A15 JED Series Page 20...
2.4. Model A12 JED A12 JED Dimensions: Maximum working height 12,1 39’ 8” Max. platform height 10,1 33’ 1” Ground clearance (with pot-hole guards lifted) 5’ 3” Ground clearance (with pot-hole guards lowered) 0’ 9” Max. outreach from turntable centre 23’...
Page 22
Battery power Voltage and standard battery capacity - Deep Cycle 48 / 320 48 / 320 V/Ah V/Ah Total electrolyte quantity of standard battery 8 x 11.4 8 x 3 Standard battery weight 8 x 52 8 x 115 Voltage and optional battery capacity - Drive Battery 48 / 330 48 / 330 V/Ah...
Page 23
Use and Maintenance Manual – A12 JE A15 JE A17 JE A12 JED A15 JED Series Page 23...
2.5. Model A15 JED A15 JED Dimensions: Maximum working height 15,0 49’ 2” Max. platform height 13,0 42’ 7” Ground clearance (with pot-hole guards lifted) 5’ 3” Ground clearance (with pot-hole guards lowered) 0’ 9” Max. outreach from turntable centre 8,95 29’...
Page 25
Battery power Voltage and standard battery capacity - Deep Cycle 48 / 320 V/Ah 48 / 320 V/Ah Total electrolyte quantity of standard battery 8 x 11,4 8 x 3 Standard battery weight 8 x 52 8 x 115 Voltage and optional battery capacity - Drive Battery 48 / 330 V/Ah 48 / 330...
Page 26
Use and Maintenance Manual – A12 JE A15 JE A17 JE A12 JED A15 JED Series Page 26...
2.6. Vibrations and noise Noise tests have been carried out under the most unfavourable conditions to study the effects on the operator. The level of acoustic pressure weighed (A) at work places does not exceed 70dB(A) for each electrical model. For the models equipped with diesel motor generator, the level of acoustic pressure weighed (A) at work places does not exceed 106dB(A), the level of acoustic pressure at ground control panel does not exceed 85dB(A), the level of acoustic pressure at platform control panel does not exceed 78bD(A).
SAFETY PRECAUTIONS 3.1. Personal protective equipment (PPE) Always wear personal protective equipment according to current regulations concerning industrial health and safety (in particular, hard hat and safety shoes are COMPULSORY). It is the operator or safety manager’s responsibility to choose the personal protective equipment (PPE) depending on the activity to be carried out.
3.3. Use instructions 3.3.1. General The electric and hydraulic circuits are provided with safety devices, calibrated and sealed by the manufacturer: DO NOT TAMPER WITH AND MODIFY THE CALIBRATION OF ANY COMPONENT OF THE ELECTRIC AND HYDRAULIC SYSTEMS. ▪ The machine must be used only in areas well lit up, checking that the ground is flat and firm. The machine may not be used if the lighting conditions are not sufficient.
▪ Pay particular attention to the area above the machine during lifting to avoid any crushing and collisions. ▪ During operation keep your hands in safety position, the driver has to place them as shown in picture A or B while the transported operator has to keep them as shown in picture C.
3.3.4. Wind speed according to Beaufort scale You can use the table below for a simple assessment of the wind speed. We remember that the max. limit for each machine model is indicated in the table TECHNICAL FEATURES OF STANDARD MACHINES. The machines for which the max.
3.3.5. Pressure of the machine on ground and load-bearing capacity of ground Before using the machine, the operator must make sure the floor is suitable for withstanding the specific loads and pressures on the ground with a certain safety margin. The following chart provides the parameters in play and two examples of calculation of the average pressure on the ground below the machine and max pressure underneath the wheels or outriggers (p1 and p2).
The table below shows the load-bearing capacity of the ground split up by ground type. Refer to the data contained in the specific tables of each model (chapter 2, TECHNICAL FEATURES OF STANDARD MACHINES) to obtain the figure relating to the max pressure on the ground caused by the single wheel. Using the machine is forbidden if the max ground pressure per wheel is higher than the bearing capacity of the specific type of ground on which the machine is to be used.
INSTALLATION AND PRELIMINARY CHECKS The machine is supplied completely assembled, therefore it can perform all functions in full safety as provided for by the manufacturer. No preliminary operation is required. To unload the machine, follow the instructions in chapter “Handling and carrying”.
USE INSTRUCTIONS Before using the machine read this chapter thoroughly. WARNING! Follow exclusively the instructions given in the next paragraphs and the safety rules described both hereafter and in the previous paragraphs. Read the next paragraphs carefully in order to properly understand the on/off procedures as well as all operations and their correct use.
Page 36
Drive proportional joystick control Proportional lever control pantograph up/down Proportional lever control boom up/down Proportional lever control jib up/down Proportional lever control telescopic boom out/in Proportional lever control QUICK UP/QUICK DOWN (OPTIONAL) Proportional lever control turret rotation Proportional lever control jib rotation (OPTIONAL) Platform rotation switch Platform level switch Motor generator start/stop button (models A12 JED - A15 JED)
5.1.1. Drive and steering Before carrying out any displacement operation, verify that no people are in proximity of the machine and in any case proceed with the utmost caution. IT IS FORBIDDEN to drive the machine when the platform is lifted unless the chassis is flat and steady with no holes and steps.
5.1.2. Platform positioning movements To carry out all movements other than drive, use proportional levers B, C, D, E, F, G, H and switches I and L. To achieve the movement, it is necessary to carry out the following operations in sequence: a) Press the dead-man pedal located on the platform;...
5.1.2.5. QUICK UP/QUICK DOWN (optional) This lever controls the quick lifting/lowering of the platform, while simultaneously controlling the following manoeuvres: Pantograph lifting/lowering ▪ Upper boom lifting/lowering ▪ Jib lifting/lowering ▪ ▪ Telescopic boom extension/retraction To carry out the QUICK UP/QUICK DOWN manoeuvre, use the proportional lever F. Set the proportional lever F forward for quick lifting or backward for lowering.
5.1.3. Other functions of the platform control panel 5.1.3.1. Manual horn The horn warns that the machine is moving. It is manually operated by means of the press-button S. 5.1.3.2. Emergency stop button By pressing the red emergency STOP button R all control functions are stopped. Normal functions are enabled by rotating the button of 1/4 turn clockwise.
5.1.3.4.3. Drive controller fault warning light / Diesel motor generator fault / low fuel red warning light - OPTIONAL (ZC) This warning light indicates a malfunctioning of traction controllers (electric models), generator diesel motor or low fuel. On steady indicating a traction controller fault (electric traction machines), with “CTR” alarm on the ground controls display. OPTION: On steady with machine on;...
5.1.4. “AIRO SENTINEL” Anti-Trapping System - OPTIONAL AIRO SENTINEL secondary safety system (OPTIONAL) is used to reduce the risk for the operator of being crushed against obstacles and external structures during the operations on the platform control panel. The system is equipped with: a.
5.1.4.1. SENTINEL logic movements When the operator is crushed against the BUMPER (a), in addition to what described in the previous paragraph, all the current operations automatically react as follow: Drive with lifted platform (safety speed): the current operation is immediately stopped and reversed; Drive with lowered platform (at any speed): the current operation stops slowly.
5.2. Ground control panel and electric control unit The ground control station contains some electronic boards necessary to operate the machine and to carry out safety checks. The electric control unit (or electronic control board) is inside the cowling (near the electric pump). The ground control panel is located on the rotating turret (see paragraph "Location of main components") and is used to: ▪...
The user interface display is also used during any interventions by specialized personnel to calibrate/adjust the working parameters of the machine. This function is not available to the user. 5.2.5. Powered-on machine warning light (E) The green light lit up indicates that the machine is powered-on (both with platform control panel and ground control panel). 5.2.6.
5.3. Platform access The “access position” is the only one from which loading or unloading of persons and materials is allowed. The “access position” to the work platform is the completely lowered configuration. To get on the platform: get on the platform hanging on to the entry side rails. ▪...
5.4.1. Diesel motor generator start-up It is possible to select between two operation modes: Auto ▪ ▪ Manual In "Auto" mode the motor generator turns on and off independently according to the discharge level of the battery. During the operation of the motor generator some movements take place at a reduced speed than usual one. In "Manual"...
To resume the operations: On the platform control panel: turn the emergency stop button of 1/4 turn clockwise; ▪ On the ground control panel: turn the emergency stop button of 1/4 turn clockwise; ▪ Pull the power circuit red emergency STOP button to the outside - until it locks in position - to power the unit ▪...
Connect to the power mains having the following features: Power voltage 230V ± 10% Frequency 50÷60 Hz Activated grounding line. Working protection devices according to current standards in force. Do not use extension leads exceeding 5 metres to connect to the mains. Use a cable of suitable section (min 3x2.5 mm Do not use rolled-up cables.
HANDLING AND CARRYING 6.1. Handling Before using the machine, make sure that the mechanical lock device of the turret is disabled (see figure aside). To handle the machine in normal operating conditions, follow instructions given chapter "USE INSTRUCTIONS" under paragraph "Drive and steering”. When the platform is completely lowered (booms down, telescopic boom completely in and jib at a height between +10°...
6.2. Carrying In order to carry the machine to the various working sites, follow the instructions given below. Considering the large dimensions of some models, before carrying, it is recommended to inquire about the overall dimension limits for road transport in force in your country. Before carrying the machine, turn it off and remove the keys from the control panels.
Through a lift truck of a suitable capacity (see machine weight in table “Technical features” at the beginning of this ▪ manual) equipped with forks having at least the same length as the machine width. Insert the forks as indicated by the stickers on the machine.
The maintenance operations described below refer to a machine with ordinary working use. In ▪ case of difficult conditions of use (extreme temperatures, corrosive environments, etc.) or following long machine inactivity, it will be necessary to contact the AIRO assistance service to change the intervention schedule. ▪...
7.2. General maintenance The table below indicates the main maintenance operations and their frequency. The machine is equipped with a service hour-meter. Operation Frequency Screw tightening (see paragraph "Various adjustments") After the first 10 working hours Oil level check in hydraulic tank After the first 10 working hours Check of the battery state (charge and liquid level) Every day...
7.2.1. Various adjustments Check the conditions of the following components and, if necessary, tighten after the first 10 working hours and, afterwards, at least once a year: 1) Wheel screws 2) Drive motor fixing screws 3) Steering cylinder fixing screws 4) fixing screws of steering hub pins;...
7.2.2. Greasing Grease all articulated joints equipped with greaser (or predisposition for greaser) at least every month. At least once a month, using a spatula or a brush, lubricate the telescopic extension. Moreover, always remember to grease the articulated joints: After washing the machine.
7.2.3. Hydraulic circuit oil level check and change After the first 10 working hours and, afterwards, once a month check the oil level in the tank by means of the provided indicator A in the picture aside) and make sure that it always lies between the max.
7.2.3.1 Biodegradable hydraulic oil (Optional) At the request of the customer, the machines can be supplied with biodegradable hydraulic oil compatible with the environment. Biodegradable hydraulic oil is completely synthetic, without zinc, non-polluting and highly efficient with saturated ester base, combined with special additives. The machines with biodegradable oil use the same component parts as standard machines, but the use of such type of oil is best taken into account from machine construction.
7.2.3.7 Mix Mixtures with other biodegradable oils are not allowed. The remaining amount of mineral oil must not exceed 5% of total filling quantity as long as the mineral oil is suitable for the same use. 7.2.3.8 Micro-filtration When making the conversion on second-hand machines, always take into account the high dirt dissolution power of biodegradable oil.
7.2.4. Hydraulic filter replacement 7.2.4.1. Suction filter All models are equipped with a suction filter installed inside the tank at the base of the suction tube, which has to be replaced at least every two years. To replace the suction filters installed inside the tank (see figure): Stop the machine by pressing the emergency ▪...
7.2.5. Drive reduction gear oil level check and change The oil level should be checked at least once a year. Place the machine so as to have the two caps (A and B) in the position shown in the picture aside (in a few cases it is necessary to remove the driving wheels to access the a.m.
7.2.6. Telescopic boom sliding blocks clearance adjustment Check the wear of the telescopic boom sliding blocks every year. The correct clearance between the blocks of the boom is 0,5-1 mm; in case of higher clearance tighten the sliding blocks as follows: Remove locking ring A.
7.2.7. Circuit movements pressure relief valve operation check 7.2.7.1. Pressure relief valve of proportional movement circuit The pressure relief valve described controls the maximum pressure on the circuit of proportional movements (pantograph, upper boom, telescopic boom, jib, turret rotation, jib rotation).
7.2.7.2. Pressure relief valve of ON-OFF movement circuit The described pressure relief valve controls the maximum pressure of the ON-OFF movement circuit (steering, cage rotation, cage levelling). Normally, this valve does not require any adjustment, since it is calibrated at the factory before the machine is delivered.
7.2.8. Operation check of the turret inclinometer WARNING! Usually the inclinometer does not need to be adjusted unless the electronic control unit is replaced. The equipment necessary for the replacement and adjustment of this component is such that these operations should be carried out by skilled personnel. AS THIS OPERATION IS VERY IMPORTANT IT IS TO BE CARRIED OUT BY SKILLED TECHNICIANS ONLY.
Page 68
SHIMS A12 JE A12 JED – A15 JE – A15 JED A17 JE A [mm] B [mm] WARNING! The dimensions of shims A and B refer to max. allowed inclination as indicated in table “TECHNICAL FEATURES”. To be used during the inclinometer calibration. Use and Maintenance Manual –...
AS THIS OPERATION IS VERY IMPORTANT IT IS TO BE CARRIED OUT BY SKILLED TECHNICIANS ONLY. The AIRO self-propelled articulated boom aerial platforms are equipped with a sophisticated overload controller. Normally the overload controller does not require any adjustments, since it is calibrated in the factory before the machine is delivered.
The system needs calibration: In case of replacement of one of the items composing the system. ▪ When, following an excessive overload or a collision, without the excessive load the danger condition is signalled ▪ anyway. 7.2.10. Overload controller by-pass – ONLY FOR EMERGENCY OPERATIONS In case of fault and impossibility to calibrate the device, a by-pass of the system is possible by means of locking key switch (A) under the control panel.
7.2.11. Operation check of M1 microswitches The lifting booms are controlled by microswitches: M1A on the pantograph. ▪ M1B on the boom. ▪ M1C on the Jib. ▪ M1E on the telescopic extension; ▪ ▪ M1S on the telescopic extension (only A17 JE with rotating jib).
7.2.12. Operation check of microswitches MPT1-MPT2 for A12 JE - A12 JED - A15 JE - A15 JED When one of the following booms is lifted/extended: pantograph ▪ upper boom ▪ telescopic boom ▪ one or more M1A, M1B, M1E microswitches are activated and consequently an automatic control activates the pot- hole guards, whose fully lowered position is checked by MPT1 and MPT2 microswitches.
7.2.13. Operation check of MPT1-MPT2 microswitches and PS1A-PS1B proximity sensors for A17 JE When one of the following booms is lifted/extended: pantograph ▪ upper boom ▪ ▪ telescopic boom One or more M1A, M1B, M1E microswitches are activated and consequently an automatic control activates the pot- hole guards, whose fully lowered position is checked by MPT1 and MPT2 microswitches.
Page 74
With platform in rest position (all the M1A-M1B-M1E ▪ microswitches are "free") the status of the MPT1- MPT2 microswitches is not considered. Fig. 30 Use and Maintenance Manual – A12 JE A15 JE A17 JE A12 JED A15 JED Page 74 Series...
7.2.14. Operation check of dead-man pedal safety system The platform dead-man pedal is for enabling the operation controls of the machine on the platform control panel. Check operation at least once a year. To check the “dead-man” PEDAL: Move the drive joystick forward and backward in sequence, WITHOUT PRESSING THE “DEAD-MAN” PEDAL. ▪...
7.3.2. Battery maintenance 7.3.2.1. Accessing the battery compartment The battery compartments are located under the cowlings on the sides of the machine chassis. To access the compartments and carry out maintenance operations, remove the cowlings (A), by performing the following steps: Fig.31 Open the hook (D);...
7.3.2.2. Closing the battery compartment To close the compartment after maintenance, perform the following operations: Insert the cover (C) on the battery compartment and secure it with the lobe knobs (B); Bring laterally the cowling (A) near the carriage; Hook the battery compartment to the carriage by the hook D. 7.3.2.3.
Page 78
WARNING! After charging, when the battery charger is still connected, the electrolyte density values should range from 1.260 g/l to 1.270 g/l (at 25thC). To use the battery charger follow these procedures: ▪ connect the battery charger by means of plug A to a current socket with the a.m. features Check the connection state of the battery charger through led B.
7.3.4. Battery charger: fault report The flashing LED on the battery charger indicator described in the previous paragraph indicates that a warning situation has occurred: WARNING PROBLEM SOLUTION Check the connection with the Flashing RED led Disconnected or not compliant battery batteries nominal voltage...
MARKS AND CERTIFICATIONS The models of self-propelled aerial platform described in this manual were subject to the CE type test according to the Directive 2006/42/EC. The certification was issued by: Eurofins Product Testing Italy Srl - 0477 Via Cuorgné, 21 10156 –...
10. CHECK REGISTER The check register is released to the user of the platform in conformance with annex 1 of Directive 2006/42/EC. This register is to be considered an integral part of the equipment and must accompany the machine for its entire life until its final disposal.
Page 84
REQUIRED PERIODIC INSPECTIONS BY THE REGULATORY AGENCY Date Observations Signature + Stamp Use and Maintenance Manual – A12 JE A15 JE A17 JE A12 JED A15 JED Page 84 Series...
Page 85
REQUIRED PERIODIC INSPECTIONS BY THE OWNER STRUCTURAL CHECK DESCRIPTION OF OPERATIONS TO BE PERFORMED Check the integrity of the guardrails; the harness anchoring points; state VISUAL CHECK of the lifting structure; any access ladders; rust; state of the tyres; oil leaks;...
Page 86
REQUIRED PERIODIC INSPECTIONS BY THE OWNER STRUCTURAL CHECK DESCRIPTION OF OPERATIONS TO BE PERFORMED VARIOUS ADJUSTMENTS See chapter 7.2.1 DATE REMARKS SIGNATURE + STAMP 1st YEAR 2nd YEAR 3rd YEAR 4th YEAR 5th YEAR 6th YEAR 7th YEAR 8th YEAR 9th YEAR 10th YEAR See chapter 7.2.2...
Page 87
REQUIRED PERIODIC INSPECTIONS BY THE OWNER CHECK DESCRIPTION OF OPERATIONS TO BE PERFORMED HYDRAULIC TANK AND DRIVE See chapter 7.2.3 and 7.2.5 REDUCTION GEARS OIL LEVEL Daily operation. It is not necessary to indicate its execution every day, CHECK but at least every year when the other operations are carried out. DATE REMARKS SIGNATURE + STAMP...
Page 88
REQUIRED PERIODIC INSPECTIONS BY THE OWNER CHECK DESCRIPTION OF OPERATIONS TO BE PERFORMED CALIBRATION CHECK OF MOVEMENT CIRCUIT RELIEF See chapter 7.2.7. PRESSURE VALVE DATE REMARKS SIGNATURE + STAMP 1st YEAR 2nd YEAR 3rd YEAR 4th YEAR 5th YEAR 6th YEAR 7th YEAR 8th YEAR 9th YEAR...
Page 89
REQUIRED PERIODIC INSPECTIONS BY THE OWNER CHECK DESCRIPTION OF OPERATIONS TO BE PERFORMED TOTAL OIL CHANGE IN HYDRAULIC TANK See chapter 7.2.3. (EVERY TWO YEARS) DATE REMARKS SIGNATURE + STAMP 2nd YEAR 4th YEAR 6th YEAR 8th YEAR 10th YEAR HYDRAULIC FILTER REPLACING See chapter 7.2.4.
Page 90
REQUIRED PERIODIC INSPECTIONS BY THE OWNER CHECK DESCRIPTION OF OPERATIONS TO BE PERFORMED TOTAL OIL CHANGE IN DRIVE REDUCTION GEARS See chapter 7.2.5. (EVERY TWO YEARS) DATE REMARKS SIGNATURE + STAMP 2nd YEAR 4th YEAR 6th YEAR 8th YEAR 10th YEAR Use and Maintenance Manual –...
Page 91
REQUIRED PERIODIC INSPECTIONS BY THE OWNER SAFETY SYSTEM CHECK DESCRIPTION OF OPERATIONS TO BE PERFORMED OPERATION CHECK OF THE See chapter 7.2.8. TURRET INCLINOMETER DATE REMARKS SIGNATURE + STAMP 1st YEAR 2nd YEAR 3rd YEAR 4th YEAR 5th YEAR 6th YEAR 7th YEAR 8th YEAR 9th YEAR...
Page 92
REQUIRED PERIODIC INSPECTIONS BY THE OWNER SAFETY SYSTEM CHECK DESCRIPTION OF OPERATIONS TO BE PERFORMED OPERATION CHECK See chapter 7.2.11 MICROSWITCHES M1 DATE REMARKS SIGNATURE + STAMP 1st YEAR 2nd YEAR 3rd YEAR 4th YEAR 5th YEAR 6th YEAR 7th YEAR 8th YEAR 9th YEAR 10th YEAR...
Page 93
REQUIRED PERIODIC INSPECTIONS BY THE OWNER SAFETY SYSTEM CHECK DESCRIPTION OF OPERATIONS TO BE PERFORMED DEAD-MAN SYSTEM CHECK See chapter 7.2.14 DATE REMARKS SIGNATURE + STAMP 1st YEAR 2nd YEAR 3rd YEAR 4th YEAR 5th YEAR 6th YEAR 7th YEAR 8th YEAR 9th YEAR 10th YEAR...
Page 94
REQUIRED PERIODIC INSPECTIONS BY THE OWNER SAFETY SYSTEM CHECK DESCRIPTION OF OPERATIONS TO BE PERFORMED GOING DOWN A RAMP WITH MAX. SLOPE INDICATED IN CHAPTER BRAKING SYSTEM EFFICIENCY “TECHNICAL FEATURES”, AT THE LOWEST SPEED, THE MACHINE CHECK SHOULD BE ABLE TO STOP, UPON RELEASE OF THE JOYSTICK, IN A SPACE OF LESS THAN 1.5 METERS DATE REMARKS...
Page 95
REQUIRED PERIODIC INSPECTIONS BY THE OWNER CHECK OF EMERGENCY DEVICES DESCRIPTION OF OPERATIONS TO BE PERFORMED MANUAL EMERGENCY LOWERING See chapter 5.6 CHECK DATE REMARKS SIGNATURE + STAMP 1st YEAR 2nd YEAR 3rd YEAR 4th YEAR 5th YEAR 6th YEAR 7th YEAR 8th YEAR 9th YEAR...
Page 96
COMPANY DATE MODEL SERIAL NUMBER DELIVERY DATE AIRO / Tigieffe S.r.l. SUBSEQUENT TRANSFERS OF OWNERSHIP COMPANY DATE We affirm that, as of the date quoted above, the technical, dimensional and functional features of this machine were in conformance with what was originally required and that any changes have been recorded in this Register.
Page 97
SUBSEQUENT TRANSFERS OF OWNERSHIP COMPANY DATE We affirm that, as of the date quoted above, the technical, dimensional and functional features of this machine were in conformance with what was originally required and that any changes have been recorded in this Register. THE SELLER THE PURCHASER SUBSEQUENT TRANSFERS OF OWNERSHIP...
Page 98
IMPORTANT BREAKDOWNS DATE DESCRIPTION OF BREAKDOWN SOLUTION SPARE PARTS USED DESCRIPTION CODE QUANTITY SERVICE SAFETY MANAGER DATE DESCRIPTION OF BREAKDOWN SOLUTION SPARE PARTS USED DESCRIPTION CODE QUANTITY SERVICE SAFETY MANAGER Use and Maintenance Manual – A12 JE A15 JE A17 JE A12 JED A15 JED Page 98 Series...
Page 99
IMPORTANT BREAKDOWNS DATE DESCRIPTION OF BREAKDOWN SOLUTION SPARE PARTS USED DESCRIPTION CODE QUANTITY SERVICE SAFETY MANAGER DATE DESCRIPTION OF BREAKDOWN SOLUTION SPARE PARTS USED DESCRIPTION CODE QUANTITY SERVICE SAFETY MANAGER Use and Maintenance Manual – A12 JE A15 JE A17 JE A12 JED A15 JED Page 99 Series...
Page 100
IMPORTANT BREAKDOWNS DATE DESCRIPTION OF BREAKDOWN SOLUTION SPARE PARTS USED DESCRIPTION CODE QUANTITY SERVICE SAFETY MANAGER DATE DESCRIPTION OF BREAKDOWN SOLUTION SPARE PARTS USED DESCRIPTION CODE QUANTITY SERVICE SAFETY MANAGER Use and Maintenance Manual – A12 JE A15 JE A17 JE A12 JED A15 JED Page 100 Series...
13. DECLARATION OF CONFORMITY DICHIARAZIONE CE DI CONFORMITA' - CE DECLARATION OF CONFORMITY - DECLARATION CE DE CONFORMITE' – EG KONFORMITÄTS-ERKLÄRUNG 2006/42/CE Dichiarazione Originale Original Declaration Déclaration Originale Originalerklärung Noi - We - Nous - Wir – Nosotros Tigieffe S.r.l.
Page 113
DECLARACION CE DE CONFORMIDAD - DECLARAÇÃO CE DE CONFORMIDADE - ЗАЯВЛЕНИЕ О КОНФОРМНОСТИ EC – ES PROHLÁŠENÍ O SHODĚ 2006/42/CE Declaración Original Declaração original Оригинальнaя декларация Originál Prohlášení Nosotros – Nós - мы - A mou Osobou Tigieffe S.r.l.
Page 114
DICHIARAZIONE CE DI CONFORMITA' - CE DECLARATION OF CONFORMITY - DECLARATION CE DE CONFORMITE' – EG KONFORMITÄTS-ERKLÄRUNG 2006/42/CE Dichiarazione Originale Original Declaration Déclaration Originale Originalerklärung Noi - We - Nous - Wir – Nosotros Tigieffe S.r.l.
Page 115
DECLARACION CE DE CONFORMIDAD - DECLARAÇÃO CE DE CONFORMIDADE - ЗАЯВЛЕНИЕ О КОНФОРМНОСТИ EC – ES PROHLÁŠENÍ O SHODĚ 2006/42/CE Declaración Original Declaração original Оригинальнaя декларация Originál Prohlášení Nosotros – Nós - мы - A mou Osobou Tigieffe S.r.l.
Page 116
DICHIARAZIONE CE DI CONFORMITA' - CE DECLARATION OF CONFORMITY - DECLARATION CE DE CONFORMITE' – EG KONFORMITÄTS-ERKLÄRUNG 2006/42/CE Dichiarazione Originale Original Declaration Déclaration Originale Originalerklärung Noi - We - Nous - Wir – Nosotros Tigieffe S.r.l. - Via Villa Superiore N.° 82 - Luzzara (Reggio Emilia) - ITALIA Dichiariamo sotto la nostra esclusiva Declare under our exclusive Declarons sous notre responsabilitè...
Page 117
DECLARACION CE DE CONFORMIDAD - DECLARAÇÃO CE DE CONFORMIDADE - ЗАЯВЛЕНИЕ О КОНФОРМНОСТИ EC – ES PROHLÁŠENÍ O SHODĚ 2006/42/CE Declaración Original Declaração original Оригинальнaя декларация Originál Prohlášení Nosotros – Nós - мы - A mou Osobou Tigieffe S.r.l.
Page 118
DICHIARAZIONE CE DI CONFORMITA' - CE DECLARATION OF CONFORMITY - DECLARATION CE DE CONFORMITE' – EG KONFORMITÄTS-ERKLÄRUNG 2006/42/CE Dichiarazione Originale Original Declaration Déclaration Originale Originalerklärung Noi - We - Nous - Wir – Nosotros Tigieffe S.r.l.
Page 119
DECLARACION CE DE CONFORMIDAD - DECLARAÇÃO CE DE CONFORMIDADE - ЗАЯВЛЕНИЕ О КОНФОРМНОСТИ EC – ES PROHLÁŠENÍ O SHODĚ 2006/42/CE Declaración Original Declaração original Оригинальнaя декларация Originál Prohlášení Nosotros – Nós - мы - A mou Osobou Tigieffe S.r.l.
Page 120
DICHIARAZIONE CE DI CONFORMITA' - CE DECLARATION OF CONFORMITY - DECLARATION CE DE CONFORMITE' – EG KONFORMITÄTS-ERKLÄRUNG 2006/42/CE Dichiarazione Originale Original Declaration Déclaration Originale Originalerklärung Noi - We - Nous - Wir – Nosotros Tigieffe S.r.l. - Via Villa Superiore N.° 82 - Luzzara (Reggio Emilia) - ITALIA Dichiariamo sotto la nostra esclusiva Declare under our exclusive Declarons sous notre responsabilitè...
Page 121
DECLARACION CE DE CONFORMIDAD - DECLARAÇÃO CE DE CONFORMIDADE - ЗАЯВЛЕНИЕ О КОНФОРМНОСТИ EC – ES PROHLÁŠENÍ O SHODĚ 2006/42/CE Declaración Original Declaração original Оригинальнaя декларация Originál Prohlášení Nosotros – Nós - мы - A mou Osobou Tigieffe S.r.l.
Page 122
AIRO is a division of TIGIEFFE SRL Via Villa Superiore, 82 - 42045 Luzzara (RE) ITALIA- +39-0522-977365 - +39-0522-977015 WEB: www.airo.com – e-mail: info@airo.com Use and Maintenance Manual – A12 JE A15 JE A17 JE A12 JED A15 JED...
Need help?
Do you have a question about the A15 JE and is the answer not in the manual?
Questions and answers