INFRARED VENT-FREE NATURAL GAS HEATER
OWNER'S OPERATION AND INSTALLATION MANUAL
FA-3B
FAS-3C
FA-5B
FAS-5C
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal
injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by
a qualified installer, service agency, or the
gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufac-
tured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
105566
Save this manual for future reference.
OWNER'S MANUAL
WARNING: Improper instal-
lation, adjustment, alteration,
service, or maintenance can
cause injury or property dam-
age. Refer to this manual for
correct installation and op-
erational procedures. For as-
sistance or additional infor-
mation consult a qualified in-
staller, service agency, or the
gas supplier.
WARNING: This is an
unvented gas-fired heater.
It uses air (oxygen) from the
room in which it is installed.
Provisions for adequate
combustion and ventilation
air must be provided. Refer
to Air For Combustion and
Ventilation section on page
4 of this manual.
1

Advertisement

Table of Contents
loading

Summary of Contents for Desa Glo-Warm FA-3B

  • Page 1 INFRARED VENT-FREE NATURAL GAS HEATER OWNER’S OPERATION AND INSTALLATION MANUAL FA-3B FAS-3C FA-5B FAS-5C WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
  • Page 2: Safety Information

    INFRARED NATURAL GAS HEATER SAFETY INFORMATION WARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
  • Page 3: Product Identification

    PRODUCT IDENTIFICATION Front Panel Figure 1 - Vent-Free Natural Gas Heater (Model FA-5B Shown) LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANS Z223.1, also known as NFPA 54*.
  • Page 4: Fresh Air For Combustion And Ventilation

    INFRARED NATURAL GAS HEATER FRESH AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven- tilation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.
  • Page 5: Determining Fresh-Air Flow For Heater Location

    FRESH AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Page 6: Ventilation Air

    INFRARED NATURAL GAS HEATER FRESH AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12"...
  • Page 7: Check Gas Type

    INSTALLATION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater .
  • Page 8 Figure 7 - Removing Front Panel of Heater (Model FAS-3B Shown) Removing Front Panel Of Heater Models FA-3B and FA-5B 1. Remove two screws near bottom cor- ners of lower front panel. 2. Pull bottom of lower front panel for- ward, then down (see Figure 8).
  • Page 9 INSTALLATION Continued Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater. Attaching to Wall Stud Method For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64"...
  • Page 10: Connecting To Gas Supply

    If pipe is too small, undue loss of pres- sure will occur. Typical Inlet Pipe Diameters FA-3B/FAS-3C 3/8" or greater FA-5B/FAS-5C 1/2" or greater Installation must include equipment shutoff valve, union, and plugged 1/8" NPT tap.
  • Page 11: Checking Gas Connections

    Control Valve Location Non-Thermostat Models Figure 16 - Checking Gas Joints OPERATING HEATER NON-THERMOSTAT MODELS FA-3B AND FA-5B FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.
  • Page 12: To Turn Off Gas To Appliance

    CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve. Control Knob FA-3B Figure 19 - Burner Patterns Slightly press in control knob and turn coun- terclockwise to the LOW, ME- DIUM, or HIGH positions (see Figure 19).
  • Page 13: Lighting Instructions

    OPERATING HEATER Continued THERMOSTAT MODELS FAS-3C AND FAS-5C FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A.
  • Page 14: Inspecting Burner

    INFRARED NATURAL GAS HEATER OPERATING HEATER Continued THERMOSTAT CONTROL OPERATION The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Note: For additional help, visit DESA International’s technical service web site at www.desatech.com. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM When ignitor button is pressed in, there is no spark at ODS/pilot ODS/pilot lights but flame goes out when...
  • Page 16 INFRARED NATURAL GAS HEATER TROUBLESHOOTING Continued OBSERVED PROBLEM Burner(s) does not light after ODS/pilot is lit Delayed ignition of burner(s) Burner backfiring during combustion Burner plaque(s) does not glow Slight smoke or odor during initial operation Heater produces a clicking/ticking noise just after burner is lit or shut off White powder residue forming within burner box or on adjacent walls or furniture...
  • Page 17 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 18: Specifications

    INFRARED NATURAL GAS HEATER SPECIFICATIONS FA-3B Btu (Variable) 6,000/12,000/18,000 Type Gas Natural Only Ignition Piezo Pressure Regulator Setting 6" W.C. Inlet Gas Pressure* (in. of water) Maximum 10.5" Minimum 7" Dimensions, Inches (H x W x D) Heater 23 x 18.75 x 7...
  • Page 19: Replacement Parts

    If they are unable to supply original replacement part(s), call DESA International’s Technical Service De- partment at 1-800-323-5190 for information. When contacting your dealer or DESA In- ternational, have ready: • your name • your address • model and serial numbers of your heater •...
  • Page 20: Illustrated Parts Breakdown

    INFRARED NATURAL GAS HEATER ILLUSTRATED PARTS BREAKDOWN FA-3B (See Detail) ODS/Pilot Assembly Burner Assembly 105566...
  • Page 21: Parts List

    PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. FA-3B PART NO. FA-3B L98409-02 L98005-02 L98410-02 L98103-03 L98071-01 098514-01 L98071-07 L98072-01 L98817-01...
  • Page 22 INFRARED NATURAL GAS HEATER ILLUSTRATED PARTS BREAKDOWN FA-5B TO "B1" TO "B2" TO "C1" Burner Assembly (See Detail) TO "C2" 29 30 ODS/Pilot Assembly 105566...
  • Page 23 PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. FA-5B PART NO. FA-5B L98409-01 L98005-01 L98410-01 L98103-01 L98071-01 098514-01 L98071-07 L98072-01 L98817-01 L98034-01 L98411-01 L98028-01...
  • Page 24 INFRARED NATURAL GAS HEATER ILLUSTRATED PARTS BREAKDOWN FAS-3C (See Detail) 14-1 14-2 ODS/Pilot Assembly Burner Assembly 105566...
  • Page 25 PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. FAS-3C PART NO. FAS-3C L98409-04 L98006-02 L98410-04 L98103-03 L98135-03 L99066-01 L98084-01 L98085-01 L98133-04 L98055-01 L98056-01 L98057-01...
  • Page 26 INFRARED NATURAL GAS HEATER ILLUSTRATED PARTS BREAKDOWN FAS-5C 14-1 14-2 ODS/Pilot Assembly (See Detail) TO "B1" TO "B2" TO "C1" Burner Assembly TO "C2" 105566...
  • Page 27 PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. FAS-5C 14-1 14-2 105566 PART NO. FAS-5C DESCRIPTION L98409-03 Cabinet Assembly L98006-01 Front Panel Assembly L98410-03 Reflector Unit L98103-01...
  • Page 28: Warranty Information

    GLO-WARM VENT-FREE NATURAL GAS HEATERS DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.

This manual is also suitable for:

Glo-warm fa-5bGlo-warm fas-3cGlo-warm fas-5c