1. Disassemble the piano
o Remove the action from the piano.
o Remove the stack and keys from the keyframe.
o Place the key upside down on a bench supported by two long pieces of wood to level the bottom
of the keys.
2. Placing reflective tape on keys 1 and 88
NOTE: The following procedure is the same whether a grand or vertical.
o Locate the reflective tape and paper jig in the kit.
o Starting with key 1 and 88, place the template on the front/bottom of the key and attach the
reflective tape. Do this on both keys.(See Ill. 1)
Note: Because keys 1 & 88 are wider than other white keys, the reflective tape is place on one side
of the key to line up with the optical sensor. (See Ill. 1 and the template)
for Grand Pianos
With Troubleshooting Guide
:
Illustration 1 – Locating reflective tape on keys 1 and 88
March 13, 2014

Advertisement

loading
Need help?

Need help?

Do you have a question about the ProScan and is the answer not in the manual?

Questions and answers

Summarization of Contents

Piano Installation Procedure
Disassemble Piano Action and Keys
Steps for removing the piano action and keys for installation.
Place Reflective Tape on Keys 1 and 88
Applying reflective tape to specified piano keys.
Key Marking and Tape Application
Mark Keys for Reflective Tape Position
Procedure to mark all keys for consistent reflective tape positioning.
Sensor Strip Installation
Install Sensor Strip in Piano Action
Mounting the sensor strip onto the piano keyframe.
Keyframe Modification and Pedal Sensors
Cut Keyframe for Sensor Clearance
Modifying the keyframe to ensure proper clearance for the sensor strip.
Install Pedal Sensors
Mounting optical sensors for the piano's pedals.
Cable Connections
Connect Grand and Extension Cables
Details on connecting the grand cable assembly and extension cable.
Control Unit Mounting
Mount Control Unit to Keybed
Instructions for securely mounting the control unit to the piano.
System Setup and Calibration
Initial System Setup and Calibration
Steps for initial setup and calibration of keys and pedals.
Sensor Re-calibration Process
Guide for periodic recalibration of sensors for optimal performance.
Recording Connectivity Diagrams
Wiring for iDevices and Computers
Diagrams for connecting to iDevices and computers for recording.
Troubleshooting and Problem Resolution
No Power to the System
Steps to diagnose and resolve power issues.
Calibration Not Completing
Troubleshooting steps when the system fails to calibrate.
Notes Not Calibrating or Playing Incorrectly
Resolving issues with individual notes not calibrating or playing.
ProRecord/ProScan Not Controlling iQ System
Diagnosing why the ProRecord/ProScan cannot control the iQ system.
Inaccurate Playback Issues
Steps to fix inaccurate playback issues.
Pedal Recording Failures
Troubleshooting steps when pedals fail to record.
Sensor Strip Repair
Repairing Damaged Sensor Strip Sections
Procedures for replacing damaged sections of the sensor strip.