Do not open Electronic Control Unit. There is no user-serviceable part in the control box. Repairs are only to be made by an Ozone Swim qualified Please take the time to read these instructions thoroughly before attempting technician, if the supply cord is damaged, it shall only be replaced by the to operate your unit.
CONTENTS Important Safety Information FEATURES Control Unit Features INSTALLATION Installation Guide Important Notes OPERATIONS Operating Instructions MAINTENANCE Maintenance Water Chemistry WARRANTY Warranty Information TROUBLESHOOT Troubleshooting 1 0 0 0 , 2 0 0 0 & 3 0 0 0 S E R I E S U S E R M a n U a l ®...
Control Unit Features FEATURES Ozone run indicator Air Filter Chlorine Cell Output display Ozone Output Fuse Positive Cell Lead (Red) Sanitation Switch Negative Cell Lead (Black) Master Switch Gas Sensor Connector (White) Chlorine Cell Output Control Timer Pump Outlet Socket 1 0 0 0 , 2 0 0 0 &...
INSTALLATION Step 1: Mount Ozone Swim control unit a maximum of 1.5 meters from the filter and chlorine cell. Fit two screws 380mm apart (screws supplied for control box). Install the Ozone Swim control unit a minimum of 900mm above ground level in an area protected from the elements to eliminate possible damage from severe weather conditions.
Connect supplied Teflon tubing (see label on Teflon tubing for direction ensuring non-return valve is in the correct direction) onto the ozone injector The Ozone Swim cell housing must be plumbed into the return line of the manifold by connecting to the compression fitting on venturi.
Page 7
For below water level installs, CONTROL BOX see “Flooded System” instructions. the designated times both the Ozone Swim and the and pump will activate from CHLORINATOR filter CELL in unison.
Installation with De-Gas Chamber ® Control box must be installed above water level. CONTROL BOX from CHLORINATOR filter CELL INJECTION MANIFOLD POOL DE GAS VESSEL return to pool OPERATIONS 1 0 0 0 , 2 0 0 0 & 3 0 0 0 S E R I E S U S E R M a n U a l ®...
• Ensure the cell production is at maximum To establish the salt level in an existing pool, take a water sample to your Note: If you require your Ozone Swim to be connected to an • With the unit running take a sample of water...
Page 10
Your Ozone Swim is fitted with digital display. During operation of your production relevant to the position it has been set to. By adjusting the cell Ozone Swim the display will illuminate relevant to the degree at which the output controller clockwise, you increase chlorine production and by turning chlorine output control has been adjusted.
Maintenance Replace the check valve in the Ozone Every 12 months or as required, the Teflon check valve prevents water from returning to the system, flooded systems (below water level) require a water trap (drain valve) to protect the system in the event that the check valve fails, to replace the check valve simply pull the delivery line off the check valve at both ends and replace with new check valve.
Warranty Information The Ozone Swim 1000, 2000 & 3000 series systems have a three (3) year parts replacement warranty (1 YEAR IN-FIELD) on the control box, chlorine cell/electrode, electronics and seals. Plus, a 10-year (1 YEAR IN-FIELD) warranty on the corona discharge unit (see below).
No display • No mains power • Ensure there is mains power TROUBLESHOOT available • Ozone Swim plug removed from power point • Ensure Ozone Swim is plugged into power point and • Ozone Swim fuse blown its turned on •...
Page 14
Copyright Notice: Copyright 2018 by Ozone1 Pty Ltd, Australia. All rights reserved. No parts of this publication may be reproduced, transmitted or stored in a retrieval system in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Ozone1 Pty Ltd.
Need help?
Do you have a question about the 2000 Series and is the answer not in the manual?
Questions and answers