vacuubrand VSP 3000 Instructions For Use Manual

Pressure transducer

Advertisement

Quick Links

Documents are only to be used and distributed completely and unchanged. It is strictly the users´ responsibility to check carefully
the validity of this document with respect to his product.
page 1 of 24
Technology for Vacuum Systems
Instructions for use
VSK 3000
VSP 3000
Pressure transducer

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VSP 3000 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Safety Information
General Information and Safe Operation
Read manual before use. Do not operate damaged equipment. Ensure correct connection and use.
Intended Use and Environmental Conditions
Use as designed only. Adhere to ambient/gas temperatures. Avoid explosive atmospheres.
Connecting and Operating the Transducer
Avoid overpressure, ensure gas-tight connections, and check supply voltage. Observe pressure limits.
Maintenance, Repair, and Disposal
Return to factory for repair. Opening voids warranty. Follow safety and disposal guidelines.
Equipment Marking (ATEX) and Technical Data
ATEX Classification and Restrictions
Details ATEX classification validity and operational restrictions based on equipment marking.
VSK 3000 Technical Specifications
Provides detailed technical data for the VSK 3000 pressure transducer.
VSP 3000 Technical Specifications
Provides detailed technical data for the VSP 3000 pressure transducer.
Wetted Parts and Transducer Operation
Wetted Materials for Transducers
Lists components and their respective wetted materials for VSK 3000 and VSP 3000.
VSK 3000 Operation Principle
Explains the capacitive measurement principle of the VSK 3000, independent of gas type.
Changing VSK 3000 Vacuum Connector
Instructions for installing hose nozzles and PTFE tubing connections on the VSK 3000.
VSK 3000 and VSP 3000 Setup and Operation
VSK 3000 Prior to Operation and VACUU-BUS
Guidance on connecting the VSK 3000 via VACUU-BUS, proper mounting, and communication.
VSP 3000 Operation Principle and Handling
Explains the thermal conductivity principle and general handling for the VSP 3000.
VSP 3000 Prior to Operation and VACUU-BUS
Guidance on connecting the VSP 3000 via VACUU-BUS, proper mounting, and communication.
VSP 3000 During Operation and Cleaning
Describes exponential notation display and procedures for cleaning the VSP 3000.
VSP 3000 Adjustment
Procedure for readjusting the VSP 3000 based on operating conditions or cleaning.
Calibration and Service Procedures
Factory Calibration and Measurement Control
Details the accredited calibration laboratory, traceability, and compliance with ISO standards.
Repair, Maintenance, and Return Guidelines
Guidelines for returning devices for service, including safety clearances and packaging.
Scrapping and Waste Disposal
Safe disposal methods for equipment and components, adhering to environmental regulations.
Health and Safety Clearance Form
Device Information and Substance Declaration
Records device history, contact with substances, and risk levels.
Decontamination and Safety Measures Declaration
Confirms decontamination status and required safety measures for personnel.
Legal Declaration and Liability Statement
User's binding declaration of information accuracy and acceptance of liability.
Declarations of Conformity
EU Declaration of Conformity
Manufacturer's declaration of compliance with EU directives and harmonized standards.
China RoHS 2 Declaration
Details hazardous material content and Environmental Protection Use Period (EPUP).

Table of Contents