GSM/GPRS/3G/4G/NB-IoT Sensor To Cloud IoT Series Sensor To Cloud User Manual Version:1.1 Model:IOT1xx Date:2019-08-15 All rights reserved by King Pigeon Hi-Tech. Co., Ltd. WWW.GPRS-M2M.COM...
Page 2
Sensor To Cloud IoT Series [Preface] Thank you for using the Sensor To Cloud IoT Series device of King Pigeon Hi-Tech. Co., Ltd. Reading this product description allows you to quickly grasp the function and use of this product. [Copyright statement] The ownership of this specification is owned by King Pigeon Hi-Tech.
9.2. Set the SIM card number......................24 9.3. Set time of device........................24 9.4. Set the user Tel number......................24 9.5. Query device status........................25 9.6. Set working mode........................25 Page 3 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Page 4
MQTT data format published by AIN types..............34 10.2.5. MQTT data format published by DS18B20 types............34 10.2.6. MQTT data format published by AM2301 types............34 11. Warranty..............................35 12. Appendix A - SMS Instructions Table....................35 Page 4 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Note: SIM cards are not included in the list. Optional Accessory: DS18B20 temperature detector, length: 1m, 5m, 10m, 20m AM2301 temperature and humidity detector, length: 1m, 5m, 20m DIN 35mm rail fixed support: Page 5 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Use the nano SIM card to support pin code verification and ensure the security of the card; The optional metal shell or waterproof shell, can be installed and used in the house and outdoors. Page 6 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
AIN (4~20mA or 0~5V) Green line need to distinguish GND line of DS18B20 wiring) GND line of AM2301 GND line of RS485(optional) Page 8 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
If I/O indicator light is on for 3 seconds, that indicates a successful reset (the I/O indicator light of the DO output model flash only one second to show successful). Page 9 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
(the default password is 1234), click on the connection. [Note] If the connection is not successful, please check whether the connection is secure and whether the serial number and password are correct. Page 10 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
0: Normal Mode (default): the device would be online all the time. 1: Low Power Mode: the device would be offline until the something happened, such as the alarm or timer task is triggered. [Device ID] Page 11 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Page 12
The PIN of the SIM card, 4 to 8 digits, if the SIM card is encrypted with the PIN code, fill in the correct PIN code here to unlock it, Otherwise the device will not be able to use an encrypted SIM card. Page 12 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
If checked, the number will be dialed when the alarm is triggered. The device will keep calling the next Tel number if there is not answer, until 3 times is reached. Page 13 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Main server address. If the device uses Modbus RTU protocol to connect to King Pigeon cloud platform, the server 1 is modbusrtu.kpiiot.com:4000, If the device uses the MQTT protocol to connect to King Pigeon cloud platform, the server 1 is mqtt.my-m2m.com: 1883;...
Page 15
(This item of other types of Device does not work in low power mode). [How long to reconnect after resending failed?] Page 15 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Range 0~65535 seconds, default 0, it indicating that the pulse output is always closed. [Pulse Output Interval Time] Range 0~65535 seconds, default 0. [Pulse Output Repeat Times] Range 0~65535 times, default 0. Page 16 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
[Alarm SMS Content],[Recovery SMS Content] Up to 40 characters, the SMS content sent to the authorized number when DIN alarmed or returned to normal. [Enable Recovery Inform] Page 17 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Click read to display AIN current value. [Threshold High], [Threshold Low] When the current value is between these two values, it is normal; otherwise there will be alarm; Page 18 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
When the current temperature is between these two values, it is normal; otherwise there will be alarm; Note: Threshold high and threshold low are integer; it is 10 times the real value. Page 19 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Click read to display current temperature or humidity. [Threshold High], [Threshold Low] When the current temperature or humidity is between these two values, it is normal; otherwise there will be alarm; Page 20 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Note: Make sure that RTU device and the device which connected to RTU through RS485, these 2 devices has the same RS485 parameters, otherwise they could not communicate. Page 21 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
5: Pulse Output(For DO only) Only device of the DO output is valid. DO pulse output, and pulse output parameters could be set on the [I/O Settings – DO Settings] page. Page 22 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
“SMS Format Error, Please check Caps Lock in Command!” Please check whether the Chinese and English input method or case is correct. (7) If the password is entered incorrectly, no information is returned. Page 23 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Tel number, can support up to 22 bits, support country code, such as Tel2: +86 or 0086. … Example: 1234A01T18812345679 Tel10: Inquiry Password+A Delete Password+A+x Page 24 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Note: x is Access Point Name(APN), y is username, z is password; APN: x Each item can be set up to 40 characters. User Name: y Example: 1234APpoint#user#apnpwd Password: z Inquiry Password+AP Delete Password+APDEL Page 25 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Server 2: Password+IPB+x+*+y Note: x is a server IP or domain name that can be set up to 32 characters; y for port number, range 0-65535 Domain/Server Example: connect to King Pigeon cloud platform www.kpiiot.com IP: x 1234IPmodbusrtu.kpiiot.com*4000 Port: y...
Example: setting temperature low -12.3 ℃ , high 45.6 ℃ , instruction 1234AINR1L-123H456# Humidity: Set humidity low limit 20%RH, high limit 60%RH, instruction Low: y, High: z 1234AINR2L20H60# Inquiry Password+AINR Page 27 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Caching data will exist even if the device rebooted, and it will be removed successfully until the device making sure that every piece of data is uploaded to the server effectively. So make sure that the cache data is no longer used before deleting it. Page 28 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Server query DO status Modbus message (Hexadecimal representation): 01 01 00 00 00 01 FD CA Issue data Detailed description Device ID address Function code 01, reading DO state 00 00 Reads data from the device register address, 00 00 Page 29 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Device ID address Function code 02 The data returned is 1 byte in length. The data returned is 0 (0 for open, 1 for close) A1 88 CRC validation Page 30 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Device ID address Function code 04 The data returned is 2 bytes in length. 01 C8 The data returned is 01 C8 (real value = register value/10, hexadecimal number 01 Page 31 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
CRC validation 10.2. MQTT Protocol When the device connects to King Pigeon cloud platform with MQTT, the user could use it immediately, don't need to care about the MQTT protocol. If you need to connect to your own server, the following is the protocol for you.
Device publish topic: device serial number (data filled out in the ‘Login Message’ for the ‘Network Settings’ on the configuration software) "sensorDatas": "addTime":"2019-01-02 12:34:56", // timestamp "switcher":"1", // switch type data, 0 is open, 1 is close "flag":"DI1" // DIN identification Page 33 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
MQTT data format published by AM2301 types Device publish topic: device serial number (data filled out in the ‘Login Message’ for the ‘Network Settings’ on the configuration software) "sensorDatas": Page 34 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Inquiry Device ID Password + IDE default 1. Set network parameter of Password + AP + ‘Access Point Name’ + SIM card # + ‘username’ + # + ‘password’ Page 35 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Page 36
Only for AIN input; Password + VOL=‘calibration value’ calibration value generally 3200~3400; Inquiry the calibration value Password + VOL factory accuracy of AIN calibrated and please do not set Page 36 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Page 37
Password + REBOOT Restore factory settings Password + RESET Set to Chinese Password + CH Set to English Password + EN If you have any questions, please contact us. http://WWW.GPRS-M2M.COM ---End--- Page 37 of 37 King Pigeon Hi-Tech. Co., Ltd Ver 1.1...
Need help?
Do you have a question about the IoT Series and is the answer not in the manual?
Questions and answers