CPD-100ES

5-2. CIRCUIT BOARDS LOCATION

5-3. SCHEMATIC DIAGRAMS AND PRINTED WIRING BOARDS

Note:
• All capacitors are in
F unless otherwise noted. pF:
50 WV or less are not indicated except for electrolytic.
• Indication of resistance, which does not have one for rating
electrical power, is as follows.
Pitch: 5 mm
Rating electrical power 1/4 W (CHIP: 1/10 W)
• All resistors are in ohms.
f
: nonflammable resistor.
F
: fusible resistor.
: internal component.
p
: panel designation and adjustment for repair.
• All variable and adjustable resistors have characteristic curve B,
unless otherwise noted.
e
:
earth-ground.
E
:
earth-chassis.
• The components identified by [ in this basic schematic
diagram have been carefully factory-selected for each set
in order to satisfy regulations regarding X-ray radiation.
Should replacement be required, replace only with the
value originally used.
• When replacing components identified by ], make the necessary
adjustments by using RV501 ([) as indicated. (See page 9)
Note: The components identified by shading and
¡
mark
are critical for safety. Replace only
with part number specified.
Les composants identifies per un trame et une marque
¡
sont critiques pout la securite. Ne les remplacer
que par une piece portant le numero specifie.
A
D
F
18
12 —
When replacing parts shown in the table below,
be sure to perform the safety related adjustment.
D - BOARD
Part Replaced ([)
RV501
Part Replaced (])
IC801, IC901, IC904, FBT (T501)
D511, D515, D596, R532, R533,
R534, R535, R538, R539, R540,
R541, R542, R543, R544, R545,
R807, R822, R823, R824, R939,
R996, RV501, C509, C515, C516,
C517, C519, C528, C542, C548,
C549, C802, C814, C815, C904,
C910
All voltages are in Volts.
Readings are taken with a 10
Readings are taken with a color-bar signal input.
Voltage variations may be noted due to normal
production tolerances.
*
: Cannot be measured.
Circled numbers are waveform references.
: B +bus.
: B - bus.
digital multimeter.