Summarization of Contents

General Information
Dimensions
Provides physical dimensions of the PS98i/PS9800 sensors.
Specifications
Details technical specifications including weight, materials, and performance.
How Pressure Sensors Work
Explains the principle behind submersible pressure sensors and pressure measurement.
Initial Inspection and Handling
Guidance on inspecting the sensor upon receipt and proper handling procedures.
Do's and Don'ts
Visual and textual guidelines for correct and incorrect handling practices.
Installation
Installing the Sensor
Instructions for physically placing the sensor in a well or tank and depth considerations.
Cable Wiring
Details the wiring configuration for PS98i and PS9800 models.
Desiccant Use
Explains the purpose and installation of desiccant tubes for vented sensors.
Grounding Issues
Discusses the importance of proper grounding and avoiding ground loops.
Maintenance
Desiccant Tubes
Describes maintenance for desiccant tubes, including inspection and replacement.
Removing Debris from End Cone
Provides instructions for cleaning the sensor's end cone to remove fouling.
Troubleshooting
Erratic Readings
Lists causes and solutions for inconsistent or unstable sensor readings.
Oscillating Readings
Addresses issues with readings that fluctuate abnormally over time.
Zero Readings When Pressurized
Diagnoses problems related to zero readings when the sensor is under pressure.