Theory Of Operation; To Start Heater; To Stop Heater; To Restart Heater - Desa B200 Owner's Manual

Portable forced air heater
Table of Contents

Advertisement

THEORY OF
OPERATION
The Fuel System: The air pump forces
air through the air line. The air is then
pushed through the burner head nozzle. This
air causes fuel to lift from the tank. A fine
mist of fuel is sprayed into the combustion
chamber.
Combustion
Chamber
Clean
Heated
Air Out
Fuel
Nozzle
Tank
Air For Fuel
System
Figure 3 - Cross Section Operational View
102569
The Air System: The motor turns the fan.
The fan pushes air into and around the
combustion chamber. This air is heated and
provides a stream of clean, hot air.
The Ignition System: The electronic
ignitor sends voltage to the spark plug. The
spark plug ignites the fuel and air mixture.
The Flame-out Control System: This
system causes the heater to shut down if the
flame goes out.
Motor
Spark
Burner
Plug
Fan
Head
Air Line
Fuel
To Burner
Filter
Air For Combustion
And Heating
OWNER'S MANUAL
OPERATION

TO START HEATER

1.
Air Pump
2.
Air
Intake
Filter
3.
4.
Cool Air
In
Air
Output
Filter
5.
Electronic
Ignitor
Fuel

TO STOP HEATER

1.

TO RESTART HEATER

1. Wait two minutes after stopping heater.
2.
Figure 4 - Flame-out Control Reset Button
5
WARNING: Review and un-
derstand the warnings in the
Safety Information section, page
2. They are needed to safely op-
erate this heater. Follow all local
codes when using this heater.
Follow all ventilation and safety
information.
Fill fuel tank with kerosene or No. 1
fuel oil.
Attach fuel cap.
Plug power cord of heater into three-
prong, grounded extension cord. Exten-
sion cord must be at least six feet long.
Extension Cord Wire Size
Requirements
6 to 10 feet long, use 18 AWG rated cord
11 to 100 feet long, use 16 AWG rated cord
101 to 200 feet long, use 14 AWG rated cord
Plug extension cord into standard 120
volt/60 hertz, three-hole, grounded
outlet. Heater will start when exten-
sion cord is plugged into outlet. If not,
push in flame-out control reset button
(see Figure 4).
Unplug extension cord from outlet.
Repeat steps under To Start Heater.
Flame-out
Control
Reset