Kromet 900 Series Operation And Maintenance Dokcumentation

Boiling pans

Advertisement

Fabryka Maszyn i Urządzeń Gastronomicznych
Sp. z o. o.
ul. Pocztowa 30 66-600 Krosno Odrzańskie
Tel. 68 383 5273 centrala, 68 3835431 fax, 68 383 5461 handlowy
www.kromet.com.ple-mail:handlowy@kromet.com.pl
OPERATION AND MAINTENANCE
DOKCUMENTATION
BOILING PANS
LINE 700/900
KROSNO ODRZAŃSKIE, 11 OCTOBER 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 900 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Kromet 900 Series

  • Page 1 Fabryka Maszyn i Urządzeń Gastronomicznych Sp. z o. o. ul. Pocztowa 30 66-600 Krosno Odrzańskie Tel. 68 383 5273 centrala, 68 3835431 fax, 68 383 5461 handlowy www.kromet.com.ple-mail:handlowy@kromet.com.pl OPERATION AND MAINTENANCE DOKCUMENTATION BOILING PANS LINE 700/900 KROSNO ODRZAŃSKIE, 11 OCTOBER 2013...
  • Page 2: Table Of Contents

    Appliances index ______________________________________________ Błąd! Nie zdefiniowano zakładki. Tables _________________________________________________________________________________ 1 Spare parts index _____________________________________________ Błąd! Nie zdefiniowano zakładki. Electrical installation schemes ___________________________________ Błąd! Nie zdefiniowano zakładki. Appliances description _________________________________________ Błąd! Nie zdefiniowano zakładki. First activation __________________________________________________________________________ 1 Activation method forgas boiling pans ____________________________ Błąd! Nie zdefiniowano zakładki. Activation method forelectric boiling pans _________________________ Błąd! Nie zdefiniowano zakładki.
  • Page 3: Appliances Index

    PPLIANCES INDEX 700.BEK-80 900.BEK-150 Electric boiling pans 900.BEK-200 700.BGK-80 900.BGK-150 Gas boiling pans 900.BGK-200 CAUTION: The following documentation's purpose is to provide the user with information related to purpose, construction, activation, and use of the a.m. appliances. Before connection to the electrical supply, activation, and use the user should read this documentation.
  • Page 4 700.BEK-80 700.BGK-80...
  • Page 5 900.BEK-150 900.BGK-150...
  • Page 6 900.BEK-200 900.BGK-200...
  • Page 7 ABLES Table 1. Electric and gas boiling pans line 700,900 – technical data. DIMENSIONS WATER MAXIMUM ELECTRIC TOTAL IP CODE / APPLIANCE [mm] ELECTRIC/GAS LEVEL WORKING WEIGHT POWER CAPACITY APPLIANCE PROTECTION SYMBOL (width x depth CONNECTION POWER [kW] BETWEEN PRESSURE [KG] SUPPLY TYPE...
  • Page 9 Table 3. Index of certificates of health quality of the National Institute of Hygiene. NUMBER OF CERTIFICATE OF HEALTH QUALITY OF APPLIANCE THE NATIONAL INSTITUTE OF HYGIENE 700.BEK-80 HŻ/D/3906/2/2010 900.BEK-150 HŻ/D/3906/2/2010 900.BEK-200 HŻ/D/3906/2/2010 700.BGK-80 HŻ/D/2528/2007 900.BGK-150 HŻ/D/3906/2/2010 900.BGK-200 HŻ/D/2528/2007 Table 4. Burners used in gas boiling pans. APPLIANCE SYMBOL 700.BGK-80 900.BGK-150...
  • Page 10: Spare Parts Index

    Table 7. Parameters of fuel gases used in Poland. Gas net calorific value in Gas nominal pressure Gas type Subgroup MJ/m no less than in kPa. / GZ – 35 / 25,1 / GZ – 41 / 29,3 E / GZ – 50 / 35,4 B / P / propane-butane / PARE PARTS INDEX...
  • Page 11: Electrical Installation Schemes

    LECTRICAL INSTALLATION SCHEMES 700.BEK-80...
  • Page 12 900.BEK-150, 900.BEK-200...
  • Page 13: Appliances Description

    PPLIANCES DESCRIPTION Every appliance is made of high-quality stainless steel. They are supported by four adjustable legs. Gas appliances are equipped with gas taps, which allow smooth power regulation. Every burner has a flame safety device (thermocouple). Boiling pans container consists of double jacket, heating of the container is performed indirectly by collecting heat from the steam-water jacket.
  • Page 14: Activation Method Forgas Boiling Pans

    CTIVATION METHOD FOR GAS BOILING PANS Before use make sure the space between the jackets is filled with treated water. To do this: open the overflow cock in the plumbing fixture as well as the valve that directs the water flow to the space between the jackets, when water starts leaking through the overflow cock shut the water inlet valve, wait until the leakage stops, shut the overflow cock.
  • Page 15 Figure2. Knob position - "gas tap shut". CTIVATION METHOD FOR ELECTRIC BOILING PANS Fill the space between the jackets with treated water as in the case of the gas boiling pans. • Actions related to the cooking process. o Set the mode switch on the control panel to position "2" – yellow lamp will burn, o set the power regulator to "max"...
  • Page 16: Maintenance And Repair Manual

    CAUTION: In the case of ignition of gas escaping from leaky fixture it is necessary to immediately close the pass-through tap in the gas installation outside the tilting pan and: stop the appliance operation, report the defect to the superior. WARNING: Improper handling of the appliance may result in leakage of large amount of gas or its improper combustion, which may cause explosion, fire or gas poisoning.
  • Page 17: Installation

    NSTALLATION CAUTION: Before installing and using the appliance please read carefully the following manual. CAUTION: The appliances are equipped with equipotential terminals, which are placed at their back and labelled. Before installing and using the appliances should be connected to the main equipotential bonding.
  • Page 18 CAUTION: The producer recommends that the a.m. operations are performed by authorised KROMET service. • Main burner gas jets replacement: a) remove the front panel, b) using a "14"...
  • Page 19: Packing Loading And Transport

    c) ignite the igniter sparking plug (pos.22), adjust the igniter flame by the air access rotating the pilot air screen (pos.23) (proper flame has a distinct blue-green cone inside). After the regulation if finished stick labels with information on the gas type which the appliance is adapted to at the data plate and in the warranty card.
  • Page 20: List Of Sites Collecting Used Equipment

    IST OF SITES COLLECTING USED EQUIPMENT Operator of collecting site Region (Voivodeship) City Address ARGO-FILM Lublin lubelskie Lublin 20-231 Lublinul. Zadębie 62 ARGO-FILM Łódź łódzkie Łódź 90-272 Łódźul. Wschodnia 29 ARGO-FILM Mława mazowieckie Mława 06-500 Mławaul. Sadowa 14 ARGO-FILM Nadarzyn mazowieckie Nadarzyn 05-830 Nadarzynul.
  • Page 21 WELTMAR śląskie Bielsko-Biała 43-300 Bielsko-Białaul. Podwale 53a Proper removing of a product (electric and electronic used equipment) Designation placed on the product or in texts concerning this product implies that after operation period or after losing its operational features the product should not be utilised with other waste. In order to avoid harmful influence on the natural environment and human’s health due to uncontrolled waste treatment, we kindly ask you to separate this product from other waste as well as we ask for responsible recycling so as to promote material reuse as a constant practice.