Advertisement

Quick Links

USER MANUAL
ALPHAVISION 16 and 96
CONTROL PANEL
User manual AlphaVision 16/96 *** 21 augustus 2003 ***
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 96 and is the answer not in the manual?

Questions and answers

Summary of Contents for AlphaVision 96

  • Page 1 USER MANUAL ALPHAVISION 16 and 96 CONTROL PANEL User manual AlphaVision 16/96 *** 21 augustus 2003 *** Page 1...
  • Page 2: Table Of Contents

    The AlphaVision Key-7 outdoor keypad ........
  • Page 3: General Introduction

    AlphaVision 16 A to D are used. Dividing the system in sections is used as follows: A house with 16 zones is divided in 4 sections: e.g. the zones 1 to 6 belong to section A (downstairs), zones 7 to 12 belong to section B (1st floor), zones 13 and 14 belong to section C (garage) and zones 15 and 16 belong to section D (loft).
  • Page 4: Operation

    It is possible to use 2 types of indoor keypads. The keypad below (left) is called “The AlphaVision keypad”. The layout of this keypad meets international standards. The other keypad (right) is a metal keypad.
  • Page 5: Arming With Pin-Code With Level 1

    Arming with 2-digit code Arming with the 2-digit code is identical to PIN-codes of level 1. After entering the 2 digits, the display shows e.g.: Section: AB..<#> = ON User manual AlphaVision 16/96 *** 21 augustus 2003 *** Page 5...
  • Page 6: Bypassing Zones

    Bypassing zones It is possible with the AlphaVision 16 or AlphaVision 96 to bypass zones. In fact this means that the operation of a detector will be bypassed. This is only neccesary in very special cases, for example if a detector is damaged during a rebuilding.
  • Page 7: F1# Activating The Reset Output

    F2# Doorbel on/off The AlphaVision 16 or AlphaVision 96 may be installed with a doorbell-function. The working of this doorbell- function is installed by the user by means of function 2. Executing this function, also with systems where it is of no use can not do any harm.
  • Page 8: F4# Adjust Time

    01: 111111 lev - abcdefgh smtwtfs Enter now the desired level of the PIN-code (1,2,3,4 or 5, forexample 4) followed by <#>. Notify: the sections will be shown as capitals: User manual AlphaVision 16/96 *** 21 augustus 2003 *** Page 8...
  • Page 9: F7# Start Engineermenu

    Do not use this function, unless it is asked by the installer. Push the keys <?> <8> <#> followed by a PIN-code of level 5. On the display appears the message: Start up/down- loading? (#=yes) User manual AlphaVision 16/96 *** 21 augustus 2003 *** Page 9...
  • Page 10: F10# Show Historical Overview

    Push the keys <?> <1> <3> <#> followed by a PIN-code of level 4 or 5. On the display appears the message: Log printer is turned OFF User manual AlphaVision 16/96 *** 21 augustus 2003 *** Page 10...
  • Page 11: F17# Testing The Batter(Y)(Ies)

    If some zones are open, e.g. zones 3 (living room) and 4 (computer room), then the display will show: zone 03 is open living room and a few seconds later: zone 04 is open computer room User manual AlphaVision 16/96 *** 21 augustus 2003 *** Page 11...
  • Page 12 This text is saved as: F:\MANUAL\ENGELS\CENTRALE\AVIS\AVIS96\AVISENGN.GBR User manual AlphaVision 16/96 *** 21 augustus 2003 *** Page 12...

Table of Contents