solarwatt MyReserve 800 Installation And Operating Manual

Table of Contents

Advertisement

Konfi guration EnergyManager
Geräteinstallation
Vorbereitung und Planung
EN
SOLARWATT MYRESERVE 500
SOLARWATT MYRESERVE 800
SOLARWATT MYRESERVE EXTENSION
INSTALLATION- AND OPERATING MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MyReserve 800 and is the answer not in the manual?

Questions and answers

Summary of Contents for solarwatt MyReserve 800

  • Page 1 Konfi guration EnergyManager Geräteinstallation Vorbereitung und Planung SOLARWATT MYRESERVE 500 SOLARWATT MYRESERVE 800 SOLARWATT MYRESERVE EXTENSION INSTALLATION- AND OPERATING MANUAL...
  • Page 2: Table Of Contents

    Mounting the housing body of the basic unit .............. 17 Mounting the MyReserve Extension housing body ............ 18 Insert cables into the housing body ................19 Page 2 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 3 MyReserve 800, AC Sensor 63 and EnergyManager circuit diagram ...... 51 12.3 LED status indicator ......................52 12.4 Technical specifications ..................... 53 13 Further applicable documents ..........59 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 3...
  • Page 4 MyReserve is protected from solid foreign objects with IP31 a diameter of 2.5 mm or larger, protection from dripping water. Page 4 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 5: General Information

    © SOLARWATT GmbH 2017 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 5...
  • Page 6: Brief Description Of Myreserve

    (flour dust, saw dust, etc.) • Do not connect MyReserve to PV systems in which • Do not expose MyReserve to direct sunlight Page 6 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 7: Requirements For Installers

    • Specialists who have taken part in one of SOLAR- WATT’s MyReserve certification courses Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 7...
  • Page 8: Safety

    Specifi c symbols Warning of dangerous Warning of dangers Warning of explosion- Warning of fl ammable electrical voltage from batteries substances substances Page 8 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 9: Safety Notices And General Sources Of Danger

    Damage due to incorrect handling! Failure to comply with the following instructions regarding device usage and handling can result in danger to life and limb and/or property damage to the product and other equipment; SOLARWATT assumes no liability for such hazards.
  • Page 10: Scope Of Delivery

    (base system). An additional housing for installing additi- included in the scope of delivery. onal battery modules is required for all other expansion stages (SOLARWATT Extension 2.2 and 4.4). Page 10 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 11: Required Tools, Aids And Installation Material

    MR Control 500/800 LED indicator Grip handles MR Pack 2.2 Terminal strip with terminal strip cover Cable feed for Extension MyReserve 500 MyReserve 800 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 11...
  • Page 12: Myreserve Extension 2.2 And 4.4 Layout

    MyReserve Extension 4.4 SOLARWATT MR Pack 2.2 layout Mounting bracket Connection for earthing cable Connection for battery cable (when delivered with blind plugs) Page 12 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 13: Solarwatt Ac Sensor 50 Layout

    Connection area for external conductor and neutral conductor (voltage measurement) MyReserve CAN communication EnergyManager CAN communication Feeds for external conductors (current measurement) Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 13...
  • Page 14: System Configuration With Myreserve

    In systems with the SMA Sunny boy 2.5 Inverters, the Optirac Global peak tracking must be switched off via the Bluetooth interface integrated in the inverter. Faulty charging and discharging behavior of the MyReserve can occur if this is disregarded.. Page 14 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 15: Installation

    Make sure that the wall which the MyReserve is to be installed on can support its weight (80 kg) and ensure that suitable load-bearing fastening material is used. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 15...
  • Page 16 IMPORTANT Install MyReserve at least 20 cm above the floor. Only install MyReserve on vertical walls. Page 16 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 17: Mounting The Housing Body Of The Basic Unit

    9 mm. Remove the two screws (3) and lift off the cover to expose the terminal strip. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 17...
  • Page 18: Mounting The Myreserve Extension Housing Body

    50 cm MyReserve MyReserve MyReserve 800 Extension Extension max. 210 cm MyReserve MyReserve 800 MyReserve 800 Extension Page 18 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 19: Insert Cables Into The Housing Body

    Terminal strip housing body that is marked here. Cable inlet • DC-line from inverter • power supply line • ACS data cable Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 19...
  • Page 20 Before connection, remove 12 mm of insulation marked here. from the cable ends and fi t the wire end ferrules. Page 20 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 21: Connecting The Cables And Lines

    • from the cable Before connection, remove 12 mm of insulation from the cable ends and fi t the wire end ferrules. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 21...
  • Page 22 Before connection, remove 12 mm of insulation here. from the cable ends and fi t the wire end ferrules. Page 22 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 23 Re-mount the terminal strip cover after installation of the connection cables. IMPORTANT For routing the cables in the base housing follow the instructions in chapter 5.4.2. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 23...
  • Page 24 Before connection, remove 12 mm of insulation here. from the cable ends and fi t the wire end ferrules. Page 24 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 25: Installation Of The Ac Sensor

    AC Sensor. It is not necessary to connect the AC Sensor to the protective earth conductor (PE). Re- fer to the connection diagram for the AC Sensor. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 25...
  • Page 26 (minimum Cat.5e). Use a twisted wire pair for High (H) and Low (L). In the process, connect (L) and (H) to the same wire pair. Refer to the circuit diagram for a detailed description of the connection. Page 26 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 27 MyReserve and AC Sensor 50 with 3-phase measurement circuit diagram NOTE NOTE NOTE NOTE With single-phase connection, use terminals L2 (IN/OUT) and N. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 27...
  • Page 28 D (Fig.). Connect neutral conductor N and the phase conductors L1, L2 and L3 to the terminals in connection area A (Fig.). Page 28 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 29 Ensure that the conductors that are connected to the AC Sensor 63 or should be disconnected from it are de-energized. IMPORTANT Observe the 5 safety rules! Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 29...
  • Page 30 (minimum Cat.5e). Use the same twisted wire pair for High (H) and Low (L). In the process, connect (L) and (H) to the same wire pair. Page 30 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 31 MyReserve and AC Sensor 63 with 3-phase measurement circuit diagram NOTE NOTE NOTE NOTE With single-phase connection, please observe the connection example for AC Sensor 63. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 31...
  • Page 32: Installation Of Battery Modules

    The leveling mark is now abo- ve the battery module. Page 32 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 33 Attach the jumper plug that is included in the deli- very to the unused battery cable (the longer cable!). Inspect the battery plug for integrity and damage. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 33...
  • Page 34 The Tip: In the process, hold the assembly aid from below. fastening point is located to the left on the battery modu- les (M6 female thread). Page 34 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 35 Inspect the battery plug for integrity and damage. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 35...
  • Page 36: Installation Of The Front Panel(S)

    With MyReserve 500 and 800 the screw behind the MyReserve DC cut-off switch can only be fi xed in a de-energized state for safety reasons. Page 36 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 37: Affixing Notices For The Switch-On And Switch-Off Sequences

    Once the inverter has connected and is exporting energy, turn on the AC to the My Reserve. Position „0“ Position „I“ Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 37...
  • Page 38 An exact sequence must be followed when swit- ching off the MyReserve! The following steps must be strictly observed. Position "I" Position "0" Page 38 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 39: Led Indicator

    Disconnect the AC supply on the MyReserve. The DC cut-off switch on the MyReserve remains switched on so that settings can be made on the PV inverter. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 39...
  • Page 40: Integrating Solarwatt Myreserve Into Solarwatt Energymanager

    In order to activate the product warranty for MyReserve, log in at www.solarwatt.com.au in the SOLARWATT profes- sional area. Please enter all required customer informati- on for warranty activation. Page 40 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 41: Cleaning / Maintenance & Upkeep

    Only qualified installers who are certified by SOLARWATT may perform service and maintenance work on MyReserve. The qualified installer certified by SOLARWATT must check and document all important variables such as the maximum PV string open circuit voltage and maximum PV string current prior to the final handover to the system owner.
  • Page 42 IMPORTANT Personal injury from electric shock during improper testing of the overall system. Only qualified installers who are certified by SOLARWATT may perform service and maintenance work on My- Reserve. Be aware that there may still be voltage at the PV terminals while the PV system or inverter is being tested, even if the DC cut-off switch has been switched off.
  • Page 43: Conduct In The Event Of A Malfunction

    AC Sensor 63 on the CAN bus • Provide as much detail as possible when describing the error Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 43...
  • Page 44 Do not inhale fumes, or use a self-contained bre- athing apparatus. Wear a full-body protective suit if possible. The calorific value of the battery is approx. 140 MJ. Page 44 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 45: Faq

    Performance LED displaying an error code, which can be used in error analysis. If you have a SOLARWATT EnergyManager, this analysis can also be done remotely. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 45...
  • Page 46 0%-20% charged, only the first PERFORMANCE LED illuminates, which is why there are no chase lights to indicate whether the battery is charging or discharging. Page 46 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 47: Packing, Storage, Transport

    IMPORTANT Damage or defects due to improper transport of the MyReserve or battery module The document 'SOLARWATT MR Pack 2.2 Handling and Transport Instructions' must also be observed for this purpose. Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 48: Environment

    SOLARWATT and the statutory disposal pro- disposal regulations for electronic scrap. cess required for this technology will be initiated. For this purpose, please contact SOLARWATT (australia@solarwatt. Page 48 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 49: Certification

    Location and date of installation Detlef Neuhaus Carsten Bovenschen Managing Director (CEO) Managing Director (CFO) SOLARWATT GmbH Maria-Reiche-Str. 2a 01109 Dresden www.solarwatt.de Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 49...
  • Page 50: Appendix

    12 Appendix 12.1 MyReserve 500, AC Sensor 50 and EnergyManager circuit diagram IMPORTANT Connect the bus termination to the SOLARWATT EnergyManager! Page 50 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 51: Myreserve 800, Ac Sensor 63 And Energymanager Circuit Diagram

    Vorbereitung und Planung 12.2 MyReserve 800, AC Sensor 63 and EnergyManager circuit diagram IMPORTANT Connect the bus termination to the SOLARWATT EnergyManager! Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 51...
  • Page 52: Led Status Indicator

    12.3 LED status indicator Page 52 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 53: Technical Specifications

    Type plates MyReserve 500 type plate (DE) MyReserve 500 type plate (ENG) MyReserve 800 type plate (DE) MyReserve 800 type plate (ENG) Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 53...
  • Page 54 MyReserve Extension type plate (ENG) MyReserve Extension type plate (DE) MR Pack 2.2 type plate (ENG) MR Pack 2.2 type plate (DE) Page 54 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 55 Konfiguration EnergyManager Geräteinstallation Vorbereitung und Planung Data sheets Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 55...
  • Page 56 Page 56 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 57 Konfiguration EnergyManager Geräteinstallation Vorbereitung und Planung Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 57...
  • Page 58 Page 58 Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017...
  • Page 59: Further Applicable Documents

    Circuit diagrams for SOLARWATT MyReserve 500 and SOLARWATT AC Sensor 50 • SOLARWATT MyReserve quick installation guide • SOLARWATT MR Pack 2.2 Handling and transport instructions • SOLARWATT EnergyManager quick installation guide Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017 Page 59...
  • Page 60 INFORMATION ON CLAIMS Should you have cause to complain, despite the high quality of our products, please contact your professional installer directly, or: SOLARWATT GmbH | Maria-Reiche-Str. 2a | 01109 Dresden | Germany Tel. + 49 351 8895-0 | Fax + 49 351 8895-111 | info@solarwatt.net Certified according to ISO 9001 and ISO 14001 | BS OHSAS 18001:2007 HIGHEST EFFICIENCY.

Table of Contents