Page 1
Digital Series Operating Manual 200i 1500i 800i 5000i 400i 2000i PUREX FUME EXTRACTION SYSTEMS “Protecting People and the Environment with Innovative Technology” 822005...
CONSUMABLES & SPARES ATTENTION! Filters Should always be ordered in advance of requirement from Purex or your local agent. Replacement filter part numbers are shown on the original packaging, please ensure you make a note here for future reference: Prefilter Part Numbers...
2006/95/EC Low Voltage Directive 2006/42/EC Machinery Directive we certify that the Purex equipment stated above conforms with the protection requirements of the Council Directives indicated above on the approximation of the laws of the Member States relating to electromagnetic compatibility, low voltage and machinery safety.
• Purex systems use high pressure pumps, which may cause inferior filters to burst, allowing hazardous fumes into the workplace. Do not use filters that have only been tested to BS3928, BS5295 or AS208C as these standards are flow checks only and are designed to test filters used in general dust extraction and air conditioning.
• If a special connection kit or attachment is required please contact Purex or your local agent. Ensure all connections are properly sealed and that there are no kinks in the hose. Once secured in position, connect the hose/s to the inlet/s on the machine either by pushing the hose onto the inlet or by using the connections supplied.
Please note that setting the flow level unnecessarily high may reduce filter life. Fully automatic operation The airflow rate is the only parameter that needs to be set by the operator. The Purex machine will automatically maintain the airflow level you have set without any further intervention required.
Page 9
Therefore the machine icons and filter positions (see 5,6,7) may vary depending on the type of machine you have. Chemical Filter Status (2) To monitor the status of the chemical filter, Purex systems employ built in gas sensors. If hazardous gas should, for whatever reason, pass through the machine then the operator will be alerted.
Opening the cabinet door • Ensure your process is stopped • Switch off your Purex machine at the control panel (see control system) • Turn the door lock/s on the front of the machine 180 degrees • Open the door Changing the pre-filter 200/400 - Has a pad situated in a recess underneath the main filter.
800i Alpha KompressAIR 5000i Xbase 400i 2000i Cube Buster 400i 2000i Cube Buster PUREX PUREX PUREX FUME EXTRACTION SYSTEMS FUME EXTRACTION SYSTEMS FUME EXTRACTION SYSTEMS PVC versions include an adsorbant pad under the prefilter. 200i 1500i Fume Fume 200i 1500i...
The blower inside the machine may have developed a fault. Check all cables and connections first. Then contact your supplier. The control PCB inside the machine may have developed a fault. Check all cables and connections first. Then contact your supplier. www.purex.co.uk - 12 - purex@purex.co.uk...
Note: These machines incorporate an inverter which connects the control PCB and the power supply to the blower. This inverter and its connections should also be inspected if electrical faults occur. www.purex.co.uk - 13 - purex@purex.co.uk...
6.10.5 Purex (and, where applicable, the original manufacturer of the Software) do not warrant that the functions for payment shall be of the essence. If the Purchaser fails to pay Purex any sum due pursuant to the Contract, the contained in the Software will meet Purchaser’s requirements or operate in the combination that may be selected...
Need help?
Do you have a question about the 1500i and is the answer not in the manual?
Questions and answers