Sitron SP30 User Manual

Sp series pressure transmitter

Advertisement

USER MANUAL
Installation, Operation and Maintenance Manual
Series: SP
Pressure Transmitters

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SP30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sitron SP30

  • Page 1 USER MANUAL Installation, Operation and Maintenance Manual Series: SP Pressure Transmitters...
  • Page 2: Table Of Contents

    Warranty ..........25 Sitron-USA - Phone (516) 935-8001 / Fax (800) 516-1656...
  • Page 3: Introduction

    Introduction SP Series Pressure Transmitter The SP Series of pressure transmitters are designed to measure the level or pressure of various industrial processes. Models can be mounted with various threaded or flanged process connections. All models are available with 4..20mA (2 wire) output (or voltage outputs). The SP/FA line coms with an integrated Zero and Span adjustment.
  • Page 4: Models & Dimension

    Models & Dimensions Pressure transmitters models (unit: mm) SP10 SP68 23,5 NPT/BSP NPT/BSP Ø 26.5 SP21 SP30 2” Tri-clamp Threaded 26.5 Hex.15/16” 1/4”NPT/BSP SP21 Adapter 1/4” to 1.1/2” 1/4” to ½” or 2” TC Hex. 1” 10mm 1/2”NPT/BSP 19mm 50.8 1.1/2”...
  • Page 5 Models & Dimensions SP98 (unit: mm) DIN connector M12 connector Standard Standard 1 ½ or 2” TC 1 ½ or 2” TC Hex. NPT/BSP NPT/BSP 1 ½” 50.8 1 ½” 50.8 2” 2” SP96 (unit: mm) SP81 M12 connector M12 connector Threaded 1 ½...
  • Page 6 Models & Dimensions SP98FA with Housing Threaded 1 ½ or 2” TC Hex.1 5/8” NPT/BSP 1 ½” 50,8 2” SP96FA with Housing Threaded 1 ½ or 2” TC NPT/BSP 1 ½” 50,8 2” Process Connections ANSI 150# Threaded Connections Tri-Clamp Connection Flange Connections ANSI 300# 3/4”...
  • Page 7: Electrical Connection

    Electrical Connections M12 connector DIN 43650 connector 2 and 3 wires 2 and 3 wires 4...20mA (2 wires) 4...20mA (2 wires) Passive Active Supply 4...20mA Pressure Pressure Active Transmitter Transmitter Passive 24Vdc Input 4 ... 20 mA 4...20mA 1...5Vdc (3 wires) Pressure Transmitter Supply...
  • Page 8 Electrical Connections SP10 & SP68 SP68 4...20mA (2 wires) 4...20mA (2 wires) Passive Active Red (+) Supply Black (-) 4...20mA Pressure Pressure transmitter Active transmitter Passive SP10 24Vdc Input Red (+) 4 ... 20 mA 4...20mA Green (-) SP10 ‘...
  • Page 9 Electrical Connections SP96FA & SP98FA Zero & Span adjustment Supply 4...20mA (2 wires) Supply 4...20mA Load impedance SP96FA SP98FA 1200 1000 36[V] 30 [V]...
  • Page 10: Mounting Notes

    Mounting Notes 1) Use PTFE tape or o'rings to seal the system. Transmitters with cable gland: Tighten the cable gland as much as possible so that the cable is securely in place and cannot be pulled through the cable gland. This will help insure that no moisture is able to infiltrate into the housing.
  • Page 11: Installation

    Installation Pressure of the Liquid Column Water Column System MKgfs System MKS P(mH2O)= relative density.h(m) P(Kgf/m2)= Specific Gravity(Kg/m3). h(m) P(KPa)= density(Kg/m3). g(m/s). h(m) Max. Principle of Operations 4...20mA The weight of the column of liquid Pressure generates hydrostatic pressure on the diaphragm of the sensor.
  • Page 12 Fig. 4 Membrane infiltrating into the transmitter (Fig 5). Flange Use a cable with vent tube for all Sitron transmitter Seal models so that the linearity of the output signal and the operation of the unit is not compromised (this special cable can also be provided by Sitron) (Fig.
  • Page 13: Calibration

    Calibration SP98FA and SP96FA Before the calibration of the unit is first tested, the process should be free of pressure or (if that is not possible) the unit should first be tested outside of the vessel. Make sure the muliti-meter is correctly connected in series with the source and the instrument.
  • Page 14: Handling

    Handling Seal the thread with Teflon tape before Fig. 1 installation. Do not turn or handle by the housing (Fig. 1). When tightening the sensor, use only use the 316S.S. hexagon fitting to achieve a seal, do not twist with the body of the sensor. (Fig.
  • Page 15: Technical Specification

    Technical Specifications SP98FA Application Pressure and Level measurement for liquids and gas 12...30Vdc Power supply Consumption 22mA max. 4...20mA (2 wires ) Output Accuracy +/- 0.5% Zero & Span Adjustment Ceramic capacitive Sensor type Range -1 to 40 Bar Electrical connection Cable gland ½”NPT BSP or NPT - flange or sanitary Process connection...
  • Page 16 Technical Specifications SP96FA Application Pressure and Level measurement for liquids and gas 12...30Vdc Power supply Consumption 22mA max. 4...20mA (2 wires ) Output Accuracy +/- 0.5% Zero & Span Adjustment Sensor type 316 SS piezoresisitve silicon Range -1 to 200 Bar Electrical connection Cable gland ½”NPT BSP or NPT - flange or sanitary...
  • Page 17 Technical Specifications SP68 Red (+) Black (-) Yellow (Out) 3 wires Application Pressure and Level measurement for liquids and gas 12...30Vdc Power supply 22mA max. Consumption Protection Reverse polarity Output 4...20mA (2 wires )/ ,1...5V, 0...5V (3 wires) Accuracy +/- 0.5% 316 SS silicon piezoresistive Sensor type Range...
  • Page 18 Technical Specifications SP30 DIN 43650 Connector (+) Positivo (-) Negativo Out (V) ( ) GND Application Pressure and Level measurement for liquids and gas 12...30Vdc Power supply Consumption 22mA max. 4...20mA (2 wires ) 0...4,5V (3 wires) upon request Output Reversal polarity Protection Accuracy...
  • Page 19 Technical Specifications SP10 Red (+) Green (-) Yellow (Out) 3 wires Application Pressure and Level measurement for liquids and gas Power supply 12...30Vdc Consumption 22mA max. Reversal polarity Protection 4...20mA (2 wires ) 0...5 e 1...5V (3 wires) Output Accuracy +/- 0.5%...
  • Page 20 Technical Specifications SP21 DIN 43650 connector (+) Positive SP21- IP67 SP21 SP21- IP66 36mm (-) Negative 47mm 47mm Out (V) ( ) GND Ø 30mm Ø 30mm M12 connector Ø 30mm (+) Positive Hex. 1.1/16” (-) Negative Out (V) ( ) GND Application Pressure and Level measurement for liquids and gas Power supply...
  • Page 21 Technical Specifications SP98 / SP96 DIN 43650 connector (+) Positive (-) Negative Out (V) ( ) GND M12 connector (+) Positive (-) Negative Out (V) ( ) GND Pressure and Level measurement for liquids and gas Application Power supply 12...30Vdc Consumption 22mA max.
  • Page 22 Technical Specifications SP81 M12 connector (+) Positive (-) Negative ( ) GND Application Pressure and Level measurement for liquids and gas Power supply 12...30Vdc Consumption 22mA max. 4...20mA (2 wires ) Output Protection Reverse polarity / Electromagnetic Interference +/- 0.25% Accuracy Sensor Type Piezoresistive ceramic...
  • Page 23: Trouble Shooting

    Trouble Shooting Cause Solution Fail Call for service Deformed membrane Lack of Linearity Incorrect power supply Check the power supply Process temperature Temperature outside must be within stated range the operating range Output Signal Check the installation, Turbulence in the process Oscilating may need to install a stilling well...
  • Page 24: Ordering Information

    SP96FA SP98 DIMENSION SP98FA SP21 1/4” SP81 3/8” SP68 1/2” SP30 3/4” SP10 1” PROCESS CONNECTION 1 1/2” 2” FLANGE ANSI 150# 316 SS 3” FLANGE ANSI 150# PVC FLANGE ANSI 150# 346 SS SMS Female SMS Macho TRI-CLAMP DIN - Female 316 SS...
  • Page 25 Cancellation: Any cancellation of the Contract by the Buyer shall be effective only if made in writing and accepted, in writing by the Sitron. In such a case, Sitron is entitled to reasonable cancellation charges including but not limited to labor, material and other...
  • Page 26: Warranty

    Sitron's field technicians or Sitron's authorized Sales Representatives, in order to be covered by Sitron's warranty. Sitron shall be under no liability in respect to any defect from fair wear and tear, willful damage, negligence, abnormal working conditions, failure to follow Sitron's instructions (whether written or verbal), misuse, modification or alteration or attempted repair of the Goods without Sitron's approval.
  • Page 27 Sitron - Brasil 1800 Prime Place R. Baronesa de Itu, 83 Hauppauge, NY 11788 São Paulo - SP - 01231-001 PH: 516-935-8001 T .: (5511) 3825-2111 www.sitron.com FX: 800-516-1656 F .: (5511) 3825-2171 BRASIL: vendas@sitron.com USA / Other Countries: info@sitron.com...

Table of Contents