Royal Exclusiv Bubble King Double Cone 180 Operating And Maintenance Manual

Royal Exclusiv Bubble King Double Cone 180 Operating And Maintenance Manual

Skimmer

Advertisement

R
E
p
oyal
xclusiv
umps
Vorgebirgsstr. 28 // 50389 Wesseling // Germany
Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20
info@royal-exclusiv.de // www.royal-exclusiv.de
Operating and maintenance manual for Bubble King
For all Bubble King
®
skimmers
&
Double Cone skimmer 130 - 150 - 180 - 200 - 250 - 300
Since 1 986
Double Cone
®
v3.0
ENG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bubble King Double Cone 180 and is the answer not in the manual?

Questions and answers

Summary of Contents for Royal Exclusiv Bubble King Double Cone 180

  • Page 1 skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de v3.0 Operating and maintenance manual for Bubble King Double Cone ® For all Bubble King Double Cone skimmer 130 - 150 - 180 - 200 - 250 - 300 ®...
  • Page 2: Table Of Contents

    skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de Operating and maintenance manual for Bubble King Double Cone ® For all Bubble King Double Cone skimmer 130 - 150 - 180 - 200 - 250 - 300 ®...
  • Page 3: Commissioning (Putting Into Operation)

    skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de 1. Commissioning (putting into operation) In general, new skimmers require a certain amount Remove the packaging from the Bubble King Double ®...
  • Page 4 skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de Please observe the water separation line. The transition of wet water foam into dry foam takes place at the also called water/air separation line. If possible, the water level should not exceed the maximum water separation line which is usually at the end of the riser.
  • Page 5: Maintenance

    skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de 2. Maintenance We recommend the cleaning of the Bubble King Double ® Cone skimmer at frequent intervals respectively to check the needle wheel for foreign objects. To check the needle wheel ist not necessary to remove the skimmer from the filter tank. The Bubble King...
  • Page 6: Deliming And Cleaning The Impeller Of The Mrd

    skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de For assembly: fix the O-ring in position, then carefully let Important notice: the magnetic impeller with the lip on top click into place. The rear bearing bush Caution ! Strong magnetic forces !! requires spezial attention as most errors are made here.
  • Page 7: Installation Of The Red Dragon ® 3 Mini Speedy With Speed Regulation

    skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de 3. Installation of the Red Dragon ® Mini Speedy with speed regulation The pump has a DC motor and therefore is equipped with a driver unit.
  • Page 8: Decalcification, Cleaning And Assembly Of The Rd3 Mini Speedy

    skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de the decalcification purge the pump with clear water. Re- assemble the pump. Very important: Tighten the screws loosely crossed over and the fix them semi-solidly (hand tight).
  • Page 9: Cleaning And Assembly Of The Skimmer

    skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de 4. Cleaning and assembly of the skimmer Bubble King skimmers can be totally disassembled. ® Thanks to new production processes with a precision range of 100/mm, all CNC-machined parts have a so- called zero fit. This means that most of the parts are not bonded to each other, but feature precise fits.
  • Page 10: Skimmer Pot And General Information

    skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de 5. Skimmer pot and general information For ideal results follow these steps: screw on the nozzle fully, make a complete turn counter-clockwise. If air bub- bles rapidly leave the output tube, the pumping power is too high. Please screw on the nozzle until no air bubbles exit the T-piece. If the skimmer is new, screw out the noz- zle almost completely and run it in for 1-2 days. Brand-new skimmers may produce bubbles, cause overflow and be subject to extreme fluctuations. The bearingsof the pump also need approximately one week to grind in. Before first The outlet piping is rotatable. Prior to unscrewing the pot,...
  • Page 11: Cleaning The Silencer

    skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de 8. Cleaning the silencer/resonator The resonator is not glued but clamped in the nut. The si- lencer needs regular cleaning. When the pump is at rest or the water level in the filter is extremely high, some water can penetrate into the resonator.
  • Page 12: Possible Sources Of Error

    skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de Water fill level 240mm Depending on how high is the water fill level in the filter, the Bubble King Double Cone can be placed on the right ® The Bubble King Double Cone after cleaning and ®...
  • Page 13: Defects And Claims For Compensation, Disclaimer

    skimmers oyal xclusiv umps & Vorgebirgsstr. 28 // 50389 Wesseling // Germany Since 1 986 Fon +49(0)2236/88055-0 // Fax +49(0)2236/88055-20 info@royal-exclusiv.de // www.royal-exclusiv.de 10. Defects and claims for compensation, 10.2. Our warranty for defects is strictly limited to supple- mentary performance. This is upon our choice either remo- disclaimer val of defects or replacement delivery free from defects.
  • Page 14: Manufacturer's Declaration

    11. Manufacturer’s declaration 10.6. Claims against us become time-barred within a year after the initial delivery of the goods to the customer. The same applies to claims for damages regardless of their ju- Royal Exclusiv ® Titles against concerning the ridical cause. The limitation period does not apply to claims...

Table of Contents