Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Arkel Manuals
Inverter
ADrive 4B110
User manual
Arkel ADrive 4B110 User Manual
Vvvf inverter for elevators
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
page
of
82
Go
/
82
Contents
Table of Contents
Bookmarks
Table of Contents
Content
Table of Contents
Introduction
Emc Conformity
Warnings
Delivery Contents
Technical Specifications
FUSE, CONTACTOR and CABLE CROSS-SECTION
Dimensions and Mounting of Adrive
Adrive Line Filter (EMI)
Adrive Braking Resistors
RFI FILTER (Zero-Phase Reactor)
AC Line Reactor (Line Choke)
ENCABIT-Plus Module
Adrive Connections
Power Terminal Connections
Mains Power Connection
Brake Resistor Connection
Motor Connection
Control Terminal Connections
Drive Command Inputs
Control Input-Output Signals
Incremental Encoder Connection for Asynchronous Motors
Absolute Encoder Connection for Synchronous Motors
Mechanical Brake Release Monitoring
Motor & Brake Resistor Temperature Monitoring
Manual Evacuation Mode Activation Input
External 24Vdc Power Supply
The Connection between ENCABIT-Plus Module and Adrive
Inputs/Outputs on ENCABIT-Plus Module
Serial Communication with ARL-500 Lift Controller
Adrive Remote Keypad Connection
Emergency Evacuation Operation
General Information
Required Back-Up Power Supplies
Evacuation in the Lower Load Direction
Evacuation Towards Command Direction
Back-Up Power Wirings for Evacuation Operation
Process of an Evacuation Travel
Pc Connection
Adrive-Win Simulator & Monitor Software
Firmware Upgrading
Data Key
Lcd Screen and Keypad Usage
Startup Screen
Monitoring Screens
Adrive Parameters
1-Travel Curve
2-Motor Setup
3-Controller Setup
4-Key Read/Write
5-Fault History
6-Control Type
7-Language
8-Factory Default
9-Auto Tune
10-Password
11-Advanced Set
12-Battery Operation
13-Drive Mode
How to Adjust for Open Loop Practically
How to Adjust for Closed Loop Practically
DRIVING SYNCHRONOUS MACHINES with Adrive
Trips
Notes
Adrive PARAMETER LIST
Advertisement
Quick Links
1
5-Fault History
2
Adrive Parameter List
Download this manual
ADrive
VVVF Inverter
F
o
r
E
l
e
v
a
t
o
r
s
F
o
r
E
l
e
v
a
t
o
r
s
USER MANUAL
08.2012
Document Version:
4.0
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the ADrive 4B110 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Arkel ADrive 4B110
Inverter Arkel ADrive Size-B User Manual
Vvvf inverter for elevators (82 pages)
Summarization of Contents
Preface
Introduction to ADrive
EMC Conformity
Ensures compliance with industrial environment standards for emission and immunity.
Safety Warnings
Delivery Contents
Technical Specifications
Fuses, Contactors, Cable Cross-Sections
ADrive Dimensions and Mounting
Physical Dimensions: Size-B & Size-C
Details physical measurements for ADrive models Size-B and Size-C.
Physical Dimensions: Size-D
Provides physical measurements for ADrive model Size-D.
Mounting of ADrive Size-D
Step-by-step guide for mounting the ADrive Size-D unit.
ADrive Line Filter (EMI)
EMI Line Filter Dimensions
Diagram showing dimensions and installation of the EMI line filter.
ADrive Braking Resistors
Braking Resistor Dimensions
Illustrations and dimensions for ADrive braking resistor types A, B, and C.
RFI Filter (Zero-phase Reactor)
RFI Filter Wiring Diagrams
Wiring instructions for connecting RFI filters to ADrive Size-B/C and Size-D.
AC Line Reactor (Line Choke)
ENCABIT-Plus Module
ENCABIT-Plus Module Description and Mounting
Details the ENCABIT-Plus module's purpose and installation procedure.
ADrive Connections
Power Terminal Connections
Explains connections for mains, brake resistor, and motor power terminals.
Control Terminal Connections
Details connections for drive command inputs and control signals.
Incremental Encoder Connection
Guidance on connecting incremental encoders for asynchronous motors.
Absolute Encoder Connection
Instructions for connecting absolute encoders for synchronous motors.
Mechanical Brake Release Monitoring
Describes monitoring connections for mechanical brake release status.
Temperature Monitoring Inputs
Explains connections for motor and brake resistor temperature monitoring.
External Power Supply and Module Connection
Details external 24VDC supply and ENCABIT-Plus module communication.
ENCABIT-Plus Inputs/Outputs
Describes digital inputs and transistor outputs on the ENCABIT-Plus module.
Communication Interfaces
Covers serial communication with ARL-500 and remote keypad connection.
Emergency Evacuation Operation
Evacuation General Information & Power Supplies
Overview of evacuation modes and required back-up power sources.
Evacuation: Lower Load Direction
Details evacuation method in the lower load direction and power calculations.
Evacuation: Command Direction
Details evacuation method towards the command direction and power calculations.
Back-up Power Wiring
Shows wiring diagrams for battery and UPS back-up power during evacuation.
Evacuation Travel Process
Describes the sequence of operations during an elevator evacuation trip.
PC Connection and Software
ADrive-Win Software & Firmware Updates
Information on using ADrive-Win for monitoring and upgrading firmware.
Data Key for Parameter Transfer
LCD Screen and Keypad Usage
Startup and Monitoring Screens
Describes initial startup screen and various monitoring screen displays.
ADrive Parameter Configuration
1-Travel Curve Parameters
Defines parameters for elevator travel curve, speed, and acceleration profiles.
2-Motor Setup Parameters
Specifies parameters related to motor type, voltage, current, frequency, and poles.
3-Controller Setup Parameters
Details parameters for PI speed control, anti-rollback, and filters.
Parameter Groups: Key, Faults, Control, Language, Defaults
Covers parameter groups for data key, fault history, control type, language, and defaults.
Parameter Groups: Auto Tune and Password
Explains auto-tuning functions and password protection for parameter access.
11-Advanced Settings Parameters
Covers advanced settings like switching frequency, current control, and input functions.
12-Battery Operation Parameters
Defines parameters for battery voltage, direction, speed, and UPS power during evacuation.
13-Drive Mode Settings
Sets the operational mode of the drive, including normal, test, and unjamming modes.
Adjusting for Open Loop Operation
Adjusting for Closed Loop Operation
Driving Synchronous Machines
Synchronous Motor Setup: Encoder, Parameters, Autotuning
Covers encoder setup, essential motor parameters, and autotuning for synchronous motors.
Improving Start-ups
Improving Travel Comfort
Troubleshooting: Trips and Errors
ADrive Parameter List Summary
Table of Contents
Save PDF
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the ADrive 4B110 and is the answer not in the manual?
Questions and answers