ESET NOD32 ANTIVIRUS - FOR LINUX-BSD MAIL SERVER Installation Manual page 18

For linux/bsd mail server
Table of Contents

Advertisement

condition = "${if eq {$received_protocol}{virus-scanned} {0}{1}}"
transport = nod32_transport
verify = false
Note that above entry has to be placed as a first of the DIRECTORS CONFIGURATION section. You also have to define
an appropriate TRANSPORTERS CONFIGURATION entry responsible for e-mail messages delivery to nod32mda agent.
Content of the entry is as follows:
# TRANSPORTS CONFIGURATION
nod32_transport:
driver = pipe
command = /usr/bin/nod32mda -oMr virus-scanned $local_part@$domain
user = mail
group = mail
Note that in RedHat Ready and/or Novell (SuSE) Ready variation of NOD32 for Linux Mail Server the absolute path to
nod32mda module is different, so the definition of TRANSPORTS CONFIGURATION entry in this case is as follows:
# TRANSPORTS CONFIGURATION
nod32_transport:
driver = pipe
command = /opt/eset/nod32/bin/nod32mda -oMr virus-scanned $local_part@$domain
user = mail
group = mail
Be sure that the 'user' (usually 'mail') used in the above settings is listed in a 'trusted_users' list for this parameter.
Also be sure that the option ' q ualify_domain' is undefined or set to your fully qualified domain name.
With the above settings you have ensured that all the e-mail messages originally sent to local domain user will
be primarily catched by nod32mda module. Yet there remains to provide that all messages processed by nod32mda
will be sent to the appropriate mailbox. To do so, just modify parameter 'mda_path' within section [mda] of main
NOD32 configuration file. In case the absolute path to the exim is '/usr/sbin/exim' the parameter 'mda_path' will be
as follows:
mda_path = "/usr/sbin/exim"
To reread the newly created NOD32 configuration, enter the following command:
/etc/init.d/nod32d reload
To accomplish the whole procedure, one has to restart the MTA Exim.
Note that NOD32LMS/NOD32BMS provides you with the option to define NOD32 scanning engine parameters
individually for recipient users (resp. recipient domains). In this case it is necessary to pass the information about
the recipient user to nod32mda module using its command line interface. Note that in case you would like to pass
any command line parameter to the whole nod32mda agent it is necessary to prepend the parameter by sentence '-
-' , otherwise the parameter will be assumed to be passed to 'exim' specified by the 'mda_path' parameter. Thus for
instance to pass command line option --user to nod32mda agent, the parameter 'command' defined in TRANSPORTS
CONFIGURATION entry must by as follows:
command = /usr/bin/nod32mda -oMr virus-scanned $local_part@$domain \
-- --user $local_part
resp. in case of RedHat Ready and Novell (SuSE) Ready variation of NOD32 for Linux Mail Server used, the ' c ommand'
1
NOD32 for Linux/BSD Mail Server

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NOD32 ANTIVIRUS - FOR LINUX-BSD MAIL SERVER and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Nod32 antivirus system

Table of Contents