Advertisement

Quick Links

Level Switch
Manual
AQ M-Tech AB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RS and is the answer not in the manual?

Questions and answers

Summary of Contents for AQ RS

  • Page 1 Level Switch Manual AQ M-Tech AB...
  • Page 2 AQ M-Tech AB Level Switch Manual...
  • Page 3 Level Switch KS Level Switch RS Level Switch LS AQ M-Tech AB Manual version 3.4 March 2017 AQ M-Tech AB Level Switch Manual...
  • Page 4: Table Of Contents

    3. Mode ......................6 4. Level Switch Mode ..................6 5. Level Sensor Mode ..................6 6. Gel Sensor Mode ..................7 7. Installing the Level Switch ................8 8. Technical Data ................... 9 AQ M-Tech AB Level Switch Manual...
  • Page 5: Manufacturer Information

    EN 61000-6-4:2001, EN55011 (Group 1, Class B). Limited Warranty AQ M-Tech AB warrants to the original end user that the Level Switch is free from any defects in materials or workmanship for a period of one year from the date of purchase. During the warranty period, should the Level Switch have indications of failure due to faulty workmanship or materials, AQ M-Tech AB will replace it with no charge.
  • Page 6: Introduction

    Level Switch is made to be used together with the Ultrasound Controller D72 or DP72. Level Switch LS is also available ATEX certified, see Level Switch EX manual. Level Switch KS is a new Level Switch with improved specifications that can be used instead of Level Switch LS.
  • Page 7: Gel Sensor Mode

    Level Switch KS can be used in Gel Sensor Mode. The ultrasound must pass easy into the container or pipe; therefore there must be a tight ultrasound-connection without any air-gap between the Level Switch and the wall.
  • Page 8: Installing The Level Switch

    Attaching tape above or below the Level Switch does not help. The tape is supplied with the Level Switch in 500mm length and can also be ordered separately from AQ M-Tech, order number 101310. The material is polyurethane and acetone should not be used for cleaning the tape.
  • Page 9: Technical Data

    1000 – Flat RS600 KS600 1000 – Flat 1000 – Flat Level Switch Level Switch RS Level Switch LS Level Switch KS Material POM-H Container / pipe temperature -20C to 140C -15C to 60C Ambient temperature -20C to 60C -15C to 60C...
  • Page 10 Cable 90 Level Switch Level Switch RS Level Switch RSF Level Switch KS Level Switch KSF Cable 0 Level Switch Level Switch Dimensions comment Level Switch KS L = 15mm R = fit container diameter Level Switch KSF L = 20mm...

Table of Contents