® Models MP16A, MP22A, MP36C and MP49C. Questions that are not specifically answerable by these instructions should be directed to the Factory. Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage. Carefully inspect and report all damages.
SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
PRODUCT APPLICATION onstruCtion • The water purifier is designed to mount horizontally. • A drain port on the chamber aids in draining of the purifier. • The water purifier’s chamber and chamber head are passivated and electropolished type 316 Stainless Steel. •...
Pre-Filters, Reverse Osmosis, Pressure Tanks, and Pumps. This eliminates the possibility of the purified water being re-contaminated by bacteria in any of these units. imensional Figure 1 -Mighty«Pure Dimensional Drawing ® Table 2 - Mighty«Pure Dimensional Data ® Model Inlet/Outlet MP16A 8-3/4” 16” 8-3/4” 10” 16-1/2” 3-5/8” 4-5/16” 8-3/16” 3/4”m NPT MP22A 14-3/4”...
Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there is any damage to the purifier, power cord or plug. Models MP16A through MP22A are shipped with the lamp already installed, while the lamp in the MP36C and MP49C is packed separately.
Plug water purifier into approved ground fault circuit interrupt (GFCI) receptacle. Confirm lamp operation indication at sight port. 11. Once the plumbing hook ups are made, it is a good practice to disinfect the “downstream” plumbing between the purifier and point of use.
Page 8
Figure 3 - Initial Installation of Quartz Sleeve...
eCommenDeD Ptions Guardian™ Ultraviolet Monitor: Visually indicates the level of germicidal ultraviolet energy that penetrates the quartz sleeve and the water within the water purifier. The ultraviolet monitor is capable of operating an optional audio alarm and/or solenoid valve. The ultraviolet monitor will detect reduction of ultraviolet levels due to: •...
MAINTENANCE The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels, see “Water Quality” in the “Product Application” section. Ordinary maintenance consists of; • Lamp replacement is recommended every 10,000 hours of operation, approximately 12 months of continuous service. •...
Page 11
nstallation or ePlaCement Figure 4 - Lamp Replacement Step 2 - Remove End -Cap Step 3 - Withdraw Lamp Step 4 & 5 - Remove Sockets Step 6 - Remove Lamp IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GOGGLES OR A FACE SHIELD, AS WELL AS GLOVES Disconnect power to water purifier.
uartz leeve nstallation leaning or ePlaCement Figure 5 - Quartz Sleeve Installation, Cleaning or Replacement Step 4 - Remove Gland Nuts Step 5 - Remove Washer & O-Ring Step 6 - Remove Quartz Sleeve IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GOGGLES OR A FACE SHIELD, AS WELL AS GLOVES Disconnect power to water purifier.
• On Mighty«Pure Models MP16A, and MP22A, the ballast housing is mounted to the purifier chamber using four (4) ® No. 8 x 3/8” long screws. Using a Phillips cross point screwdriver, carefully remove the four (4) screws, from along the sides of the ballast housing, and set aside.
Ptional uarDian ltraviolet onitor ensor roBe leaning Figure 6 - Ultraviolet Monitor and Sensor Probe Figure 7 - Sensor Probe If after cleaning the quartz sleeve, there is no significant improvement in the ultraviolet intensity, as shown on the intensity meter, it may be necessary to clean the Ultraviolet Monitor’s sensor probe.
TROUBLESHOOTING Always disconnect power to the water purifier before performing any service or maintenance. IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel. Table 3 - Troubleshooting Problem Possible Cause Corrective Action Verify that the purifier is connected to a live power Purifier not operating No electrical power..
Promate™ Time Delay Mechanism MP16A through MP49C control valves are male NPT. Quantum™ Thermal Optimizer: MP16A through MP49C Consult Factory for other flow MP16A (1/2”) through MP22A (3/4”) control valves MP36C (1”) Promate™ Solenoid Valve MP49C (1-1/2”) MP49C (1-1/2”) MP16A (3/4”) MP22A (3/4”)
USER ASSISTANCE Please read and become familiar with Atlantic Ultraviolet Corporation Atlantic Ultraviolet Corporation ® ® the contents of this manual before makes every effort to ensure that the 375 Marcus Boulevard Mighty«Pure installing or using this unit. If after Ultraviolet Water Hauppauge, New York, 11788 ®...