Advertisement

Installer Code (Default - 728 Ultra: 282828; 738 Ultra: 383838)
Full access to programming, except user access codes (PINs). No access to arming/disarming. Use only numeric keys from [0] to [9].
Zone Recognition
Device connected to which input?
Control Panel
Input 1 =
Input 2 =
Input 3 =
Input 4 =
Input 5 =
Input 6 =
Input 7 =
Input 8 =
Keypad
Zone 1 =
Zone 2 =
Streamlined Section Programming
This is an alternate method to Hex Programming (see page 2). Addresses 000 to 043 and 300 to 527 are grouped into 68 sections where
each section contains four addresses (i.e. section 00 = addresses 000 to 003). Using this method allows you to program 8 digits
(4 addresses) without having to exit and re-enter addresses.
The keypad will not display the current data in the Streamlined Section Programming method.
1.
Press [
2.
The [
3.
Enter 2-digit [
4.
The [
5.
Enter 8-digit [
6.
The keypad will beep to indicate that the section has been programmed, data is saved and the
software has advanced to the next section.
7.
Return to step 4 or press [
System Programming Guide
Software Versions 4.4 (728ULT) and 4.1 (738ULT)
Table 1: Zone Recognition
Table 2: Streamlined Section Programming Method
] + [
ENTER
INSTALLER CODE
] and [2
] keys will flash to indicate you are in programming mode (LED keypad only).
ENTER
ND
] (00 to 67).
SECTION
] key will remain on while the [2
ENTER
] to program the section.
DATA
CLEAR
Esprit 728 Ultra & 738 Ultra - 1 - Programming Guide
&
728 Ultra
728 Ultra
No ATZ
With ATZ
Zone 1
Zones 1 & 2
Zone 2
Zones 3 & 4
Zone 3
Zones 5 & 6
Zone 4
Zones 7 & 8
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Zone 5
Zone 9
Zone 6
Zone 10
] (Default - 728 Ultra: 282828; 738 Ultra: 383838) + [7].
] key will be off (LED keypad only).
ND
] to exit programming mode.
738 Ultra
738 Ultra
No ATZ
With ATZ
Zone 1
Zones 1 & 9
Zone 2
Zones 2 & 10
Zone 3
Zones 3 & 11
Zone 4
Zones 4 & 12
Zone 5
Zones 5 & 13
Zone 6
Zones 6 & 14
Zone 7
Zones 7 & 15
Zone 8
Zones 8 & 16
Zone 9
Zone 17
Zone 10
Zone 18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 728 ultra and is the answer not in the manual?

Questions and answers

Summary of Contents for ESPRIT 728 ultra

  • Page 1 The keypad will not display the current data in the Streamlined Section Programming method. Table 2: Streamlined Section Programming Method Press [ ] + [ ] (Default - 728 Ultra: 282828; 738 Ultra: 383838) + [7]. ENTER INSTALLER CODE The [ ] and [2 ] keys will flash to indicate you are in programming mode (LED keypad only).
  • Page 2: Hex Programming

    = First digit = 4 + 2 + 1 = 7 Therefore 2-digit data = 7A Note: Values 10 to 15 represent hex digits A to F respectively. See keypad to the left. Esprit 728 Ultra & 738 Ultra - 2 - Programming Guide...
  • Page 3: Installer / Panel Answer Options

    The Standard Pulse report format can support 3- or 4-digit account numbers. The Ademco Express, Ademco Contact ID and the Pager report formats only support 4- digit account numbers. Esprit 728 Ultra & 738 Ultra - 3 - Programming Guide...
  • Page 4 [4] / [2 EMPERATURE TRBL ANUAL 159: [2] / [2 602: [4] / [1] EMPERATURE ERIODIC 161: [2] / [1] 625: [4] / [2] ESET 654: [4] / [3] YSTEM NACTIVITY Esprit 728 Ultra & 738 Ultra - 4 - Programming Guide...
  • Page 5 ___ / ___ User Code 10 ___ / ___ User Code 3 ___ / ___ User Code 11 ___ / ___ User Code 4 ___ / ___ User Code 12 Esprit 728 Ultra & 738 Ultra - 5 - Programming Guide...
  • Page 6 ]) only when ATZ is enabled (address 090, key [8]). Applies only to 728 Ultra. † = Zones 1 to 10 for the 728 Ultra and Zones 1 to 18 for the 738 Ultra Esprit 728 Ultra & 738 Ultra - 6 - Programming Guide...
  • Page 7 ___ / ___ Login (Espload) ___ / ___ No movement ___ / ___ Program Change ___ / ___ Partial Arming Future Use ___ / ___ Recent Close Future Use Esprit 728 Ultra & 738 Ultra - 7 - Programming Guide...
  • Page 8: Decimal Programming

    If address 090 key [3] ON = address 046 in hours (see page 10) 738 Ultra only: Enter “255” to enable a Timed Test Transmission when the system is armed or disarmed (see the 728 Ultra/738 Ultra Reference & Installation Manual for more information) ___ / ___ / ___ (hours) Auto test report (between "000"...
  • Page 9 Table 9: Code Priority for Codes with Bypass Access KEY SELECT: ] [2 AWAY TRBL [0] [ STAY FORCE User #: 074: User #: 17 076: User #: 33 078: Esprit 728 Ultra & 738 Ultra - 9 - Programming Guide...
  • Page 10: Input

    Stay / System A and zone 3 is defined as a 4-wire fire zone, if you are not using zone 4 (728 Ultra) or 11 (738 Ultra), it must be Auto test report / Closing delinquency timer in In hours disabled.
  • Page 11: Key Access Programming

    Do not use the Intellizone feature and an entry delay for the same zone, otherwise an alarm may occur as a user tries to disarm the system. Zones that are not selected at addresses 100 to 112 (728 Ultra) or 114 (738 Ultra) become “Delay 1” zones.
  • Page 12: Connection Diagrams

    Fault Recognition (UL/cUL) Address 088, [ ] = “OFF” (EOL resistor enabled) [0] = (See Tamper/Wire Fault definitions on ] = page 10.) STAY Address 090, [8] = “OFF” (ATZ disabled) Esprit 728 Ultra & 738 Ultra - 12 - Programming Guide...
  • Page 13: Advanced Technology Zone (Atz) Connections

    Address 090, [8] = “ON” (ATZ enabled) Address 090,[8] = “ON” (ATZ enabled) [7] = “ON” (ATZ wiring in parallel) [7] = “OFF” (ATZ wiring in serial) Other Connection Diagrams Figure 12: Connecting Keypad Zone(s) Esprit 728 Ultra & 738 Ultra - 13 - Programming Guide...
  • Page 14 - Use only the Hochicki model SLR 835BH-2 2-wire smoke detector. - 2-wire smoke detectors of different models other than the Hochicki model are not to be used. - Both the 728 Ultra and the 738 Ultra control panels support a maximum of five 2-wire smoke detectors per control panel.
  • Page 15: 728 Ultra Wiring Diagram

    - LCD Keypad 642 The maximum number of keypads per installation is For UL and cUL warnings, refer to the Warnings section in the Esprit 728 dependent on the auxiliary output, which is not to exceed Ultra & 738 Ultra Reference and Installation Manual.
  • Page 16: 738 Ultra Wiring Diagram

    The maximum number of keypads per installation is dependent on the auxiliary output, which is not to exceed 500mA. Refer to the 728 Ultra & 738 Ultra Reference & Installation Manual for the current consumption table. Refer to Figure 12 on page 13 for information on keypad zone connections.
  • Page 17: Power Down Reset

    © 2003-2005 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 6215399, 6111256, 5751803, 5721542, 5287111, 5119069, 5077549, 5920259 and 5886632. Canadian and international patents may also apply. Esprit is a trademark or registered trademark of Paradox Security Systems Ltd.
  • Page 18 Notes...
  • Page 20 780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADA Tel.: (450) 491-7555 Fax: (450)491-2313 www.paradox.ca PRINTED IN CANADA - 03/2005 7X8ULT-EP01...

Table of Contents