Troubleshooting
50PC1DR
Plasma Display Panel Troubleshooting - 2007
1

Advertisement

Table of Contents
loading

Summary of Contents for LG 50PC1DR - - 50" Plasma TV

  • Page 1 Troubleshooting 50PC1DR Plasma Display Panel Troubleshooting - 2007...
  • Page 2 Troubleshooting Overview of Topics to be Discussed •Switch Mode Power Supply •Y SUS Board •Z SUS Board •X Drive Boards Plasma Display Panel Troubleshooting - 2007...
  • Page 3 PLASMA Overview Troubleshooting Safety Rules Safety & Handling Regulations 1. Approximately 10 minute pre-run time is required before adjustment. 2. Do not exceed Higher voltage than is required for the product. 3. Be cautious of electric shock from the PDP module since the PDP module uses high voltage, and it is recommended that you should not touch the drive circuits for at least one minute because of residual current stored.
  • Page 4 Switch Mode Power Supply Troubleshooting This Section of the Presentation will cover troubleshooting the Switch Mode Power Supply for the Single Scan Plasma. Upon completion of the section the technician will have a better understanding of the operation of the Power Supply circuit and will be able to locate voltage and test points needed for troubleshooting and alignments.
  • Page 5: Troubleshooting Steps

    Troubleshooting Steps • Define Look at the symptom carefully and determine what circuits could be causing the failure. Use your senses Sight, Smell, Touch and Hearing. Look for burned parts and check for possible overheated components. Capacitors will sometimes leak dielectric material and give off a distinct odor. Frequency of power supplies will change with the load, or listen for relay closing etc.
  • Page 6 SMPS Operating Modes Troubleshooting • Deep Sleep Mode - Guide Plus not programmed or Cable Card not installed and set is plugged in and turned off. The SMPS outputs S 5v (Standby). Guide Plus has been programmed the set will remain in Standby Mode when turned off for approximately 2 hours and go into Deep Sleep Mode.
  • Page 7 Troubleshooting Switch Mode Power Supply (SMPS) Voltages • VS 196v used to drive the Horizontal Grid Voltage, Y SUS, and Z SUS. Measured from pins 8, 9, and 10 of connector P805 to chassis ground. Adjusted at VR951 • VA 60v used to drive the Vertical Grid Voltage, X Boards and in the IPM Circuits to develop Y and Z Drive waveforms.
  • Page 8 Troubleshooting Power Supply VS Adjust Adjust VA Source 380 Volt Supply VS Source Control IC 19v Audio Supply 12V,6V, 5V and 3.3V Source 3.3v Adjust Standby Circuit AC Input Circuit P802 P803 P800 Plasma Display Panel Troubleshooting - 2007...
  • Page 9 Troubleshooting Power Supply Low Voltage Connectors P800 P800 P803 P802 1) AC-D 1) 3.3V 1) 19V 2) RL-ON 2) 19V 2) 3.3V PIN1 3) S-5V 3) GND 3) GND 4) GND 4) GND 4) GND 5) VS-ON 5) 6V 5) 6V 6) 5V-D 6) GND 6) 6V...
  • Page 10: Troubleshooting

    Power Supply Voltage Distribution Troubleshooting PC901 Q801 U801 D951 Q607 T801 D952 Q606 R606 Q854 R963 R607 U851 T902 Q601 D953 5V-M L851 T901 Q602 Q855 D271 Q281 C855 D602 P802 R870 L601 R162 380V D261 U151 T112 D601 3.3V Q151 Q252 Standby...
  • Page 11 Troubleshooting Y SUSTAIN BOARD Troubleshooting This Section of the Presentation will cover troubleshooting the Y SUS Board for the Single Scan Plasma. Upon completion of the Section the technician will have a better understanding of the operation of the circuit and will be able to locate voltage and resistance test points needed for troubleshooting and alignments.
  • Page 12 Troubleshooting Important Note • The following voltages and waveforms should be adjusted in the order they are presented. • Always adjust the DC levels before the waveform adjustments to most accurately set the Plasma Display Panel. Voltmeter Adjustments to Y SUS •...
  • Page 13 Troubleshooting Waveform Adjustments Y SUSTAIN • Ramp Up Used to shape the Y Drive Waveform by changing the pitch of the Top Ramp • V SET DN Used to shape the Y Drive Waveform by changing the pitch of the Bottom Ramp •...
  • Page 14 Panel Waveform Adjustment Troubleshooting Single Scan Panel *Waveforms may vary with different Y_SUSTAIN PCB part #’s. RAMP UP Normal Waveform Scope TP 35 micro seconds 180 micro seconds VSET UP Ground VSET DN +VSC This test point is the reference for all the following signals referred to here.
  • Page 15 Troubleshooting Single Scan Panel Panel Waveform Adjustment Ramp up too high Noticeable low level color distortion with the Ramp_up too high. Ramp up too low Noticeable low level color distortion with the Ramp_up too low. Plasma Display Panel Troubleshooting - 2007...
  • Page 16 Troubleshooting Single Scan Panel Panel Waveform Adjustment Vset DN too low The center begins to wash out and arc due to decreased Vset DN time. Vset DN too high All of the center washes out due to increased Vset_DN time. Plasma Display Panel Troubleshooting - 2007...
  • Page 17 Troubleshooting Single Scan Panel Panel Waveform Adjustment Vset UP too high The center begins to wash out and arc due to Vset UP Peeking too late and alters the start of the Vset DN phase. Vset UP too low Very little alteration to the picture, the wave form indicates a distorted Vset UP.
  • Page 18 Troubleshooting Single Scan Panel Panel Waveform Adjustment -VY too low (-154vdc) Colors and the image will bloom slightly and the unit will have difficulty with clean frame changes in a quickly altering image. -VY too high (-227vdc) The center begins to wash out and arc due to – VY running to long and clipping.
  • Page 19 Troubleshooting Single Scan Panel Panel Waveform Adjustment VSC too low (77 Volts) The image will show very little change but there will Be some distortion in a quickly changing image. VSC too high (140 Volts) The image will show very little change but there will Be some distortion in a quickly changing image.
  • Page 20 SINGLE SCAN PDP 50PX3 ZBIAS adjustment: On the Z-Sustain PCB With the DVM across R92 adjust the potentiometer till the DVM reads 93 vdc. Plasma Display Panel Troubleshooting - 2007...
  • Page 21 Troubleshooting Y sustain board Control Board supplies Logic Signals to the Y Sustain Board for processing, which then develops the signal to drive both of the Y Drive Boards sequentially with the Y Output Waveform for PDP operation. Logic signals from Control Board <...
  • Page 22 Troubleshooting Y Sustain Board Diagram of Y Sustain Board Power Supply Board - SMPS Z SUS Board Distributes 5v VA VS Receive 5V,Va, Vs Distributes 5v Control Board from SMPS Distributes 5v VA Logic signals needed to generate drive waveform IPM generates Generates Vsc, -Vy from Sustain Waveform...
  • Page 23 Troubleshooting IPM (Intelligent Power Module) SUS_UP SUS_UP ER_UP ER_UP ER_DN ER_DN SUS_DN SUS_DN SUS_DN SUS_DN There are two IPMs used in 50PC1DR on the Y Sustain Board. 1. SUS IPM (IC202) 2. ER IPM (IC201) Role of IPMs 1. Generate Sustain Waveform (square wave) – SUS IPM. 2.
  • Page 24 Troubleshooting How to check IPM (Resistance ‘Diode Check’, board removed from set) Forward Test : 1. GND (+), Sus-out ( - ) 2. Sus-out (+), Vs ( - ) 3. ER-DN ( - ), GRND (+) 4. GRND ( + ), ER-UP ( - ) 5.
  • Page 25 Troubleshooting ▶ Major defect : IPM fail, FET fail, fuse Defect name Description of defect Part Defect display No display ( If the ER IPM failed, The screen can display normal picture for few minutes) IPM Fail (If SUS IPM failed, top portion of Drive <...
  • Page 26 Troubleshooting Y SUS Plasma Display Panel Troubleshooting - 2007...
  • Page 27 P11 to Z SUS Board Troubleshooting Y SUSTAIN 5v VA ER_IPM (IC201) floating ground Supplies Logic signals to Y Drive Boards to sequentially scan the Horizontal Grid floating ground Ground VA, VS, and 5v all supplied from SMPS Ground SUS_IPM (IC202) Y SUS output Ground 5v to the Control Board...
  • Page 28 Troubleshooting Single Scan Y Drive Output Waveform Plasma Display Panel Troubleshooting - 2007...
  • Page 29 Troubleshooting Resistance Measurements performed with board installed and no power applied - (all resistance measurements are approximations) • 3 Meg measured from chassis ground • 18 Meg measured from chassis ground • 2K measured from chassis ground • Measure in Diode Mode at VSC TP •...
  • Page 30: Y Drive Board

    Y DRIVE BOARD Troubleshooting Plasma Display Panel Troubleshooting - 2007...
  • Page 31 Troubleshooting Y DRIVE Boards Y-Drive Board works as a path supplying Sustain waveform and Reset waveform which is made in Y SUSTAIN B/D to the Panel through SCAN DRIVER IC Supplies a waveform which selects horizontal electrode sequentially. * 50PC1DR uses 12 DRIVER ICs (TOP, BOTTOM: 6 each) Plasma Display Panel Troubleshooting - 2007...
  • Page 32 Module check point Troubleshooting Defect Condition Visual check of YDT-BTM Horizontal bar displays across the screen due to no Defect : Horizontal Bar or Shutdown Scan Pulse caused by Scan IC Failure. Failures can be found, sometimes by a visual inspection of the Y DRIVE Board scan IC’s .
  • Page 33 Z SUSTAIN Board Troubleshooting This Section of the Presentation will cover troubleshooting the Z-SUS Board Assembly. Upon completion of this section the Technician will have a better understanding of the circuit and be able to locate voltage and resistance test points needed for troubleshooting and alignment. •...
  • Page 34 Troubleshooting Input Voltages from the Y SUS Board Supplied to IC7 the SUS_IPM through coil FL152 and to the Primary Winding of Transformer T2 of the Z Bias Circuit. Input measured from P151 pin 12 to chassis ground. Supplied to the ER_IPM through parallel resistors R91 and R9 and through Diode D84. The VA voltage is also routed to connectors P152 and P153 at pin 7 of each connector.
  • Page 35 Troubleshooting Z SUSTAIN Board R111 R25 Z BIAS TP IC7 SUS_ IPM IC5 ER_IPM Z BIAS Adjust Control P151 P151 and P152 Supplies VA and 5v to X Boards 18v IPM at right side of R100 P1 from control board Timing, Data, and control signals Plasma Display Panel Troubleshooting - 2007...
  • Page 36 Z SUSTAIN Voltage Distribution Troubleshooting From Y SUS Board FL152 To X Drive Boards Plasma Display Panel Troubleshooting - 2007...
  • Page 37 Troubleshooting Waveforms Z SUSTAIN Board • Input signals to the Z SUS Board at P1 from the Control Board are routed through IC1 and IC82 to the IPM. These signals are used to develop the Z SUS Drive Waveform to drive the PDP. Plasma Display Panel Troubleshooting - 2007...
  • Page 38 Troubleshooting Z Board SUS Board Waveform inputs from the Control Board NOTE: These voltages will vary due to changes Pin 1 in design and variations in the PDP panel. PIN1 PIN2 PIN3 PIN4 PIN5 PIN6 PIN7 PIN8 PIN9 PIN10 PIN11 PIN12 Plasma Display Panel Troubleshooting - 2007...
  • Page 39 Troubleshooting Z SUSTAIN Board Provides the SUSTAIN PULSE and ERASE PULSE for generating SUSTAIN discharge in the panel by receiving LOGIC signals from the CONTROL B/D. This waveform is supplied to the panel through FPC(Z). < Probe connect point to Oscilloscope to check Z wave form >...
  • Page 40: Y Sus Board

    Troubleshooting Z SUSTAIN BOARD Distributes 5v, VA, VS Y SUS Board Distributes Logic Signals Distribute 5v, VA Receive 5v, VA, VS Control Board X Board Center and Right IPM generates erase, Generates Z Bias sustain waveform Display Panel FET Makes Drive waveform Via FPC (flexible printed circuit ) Plasma Display Panel Troubleshooting - 2007...
  • Page 41 Troubleshooting Z SUS IPM (Intelligent Power Module) SUS_UP ER_DN SUS_DN ER_UP SUS_DN There are Two IPM ( Intelligent Power Module) on the Z sustain board of the 50PC1DR. One is SUS IPM (IC7) , another is ER IPM (IC5) Role of IPM 1.Generate sustain and erase waveform( square wave ) –...
  • Page 42: Cable Connection

    Troubleshooting ▶ Major defect IPM fail cable connection Defect name Description of defect Part Defect display IPM Fail Dark display < Dark display > If the cable was not < No display > P1 Cable connected, connection There is no display Plasma Display Panel Troubleshooting - 2007...
  • Page 43 FPC (Flexible Printed Circuit) Removal for Z Board Replacement Troubleshooting Pull out Lock as shown in circles Pull FPC Connector as shown in arrow. Pull Lock apart to remove Resistance Measurements • VS Started at 340 meg settled approx 1 meg •...
  • Page 44: Control Board

    Troubleshooting CONTROL Board Troubleshooting Plasma Display Panel Troubleshooting - 2007...
  • Page 45 Yellow = ON Weight Voltage D15 - 8 Regulator D16 - 4 D17 - 2 Flash ROM D18 - 1 TEST Pattern AUTOGEN P1 Connector Voltage Regulator (Micro Control Module) LG Part Number Label Plasma Display Panel Troubleshooting - 2007...
  • Page 46 Control Board Troubleshooting 1. Check LED ( Normal status lighting or not ) 100.0 MHZ 2. CHECK OSC X1 output. (100MHZ) OSC(X1) 3. Check CTRL input voltage Check oscillator state. (CONNECTOR P10) Be careful to avoid physical shock. 4. CHECK each FET 3.3V, 5V,1.8V., 2.4V Check FET’s Probe...
  • Page 47 Control Board Troubleshooting ▶ Main Defect : MCM , connector, oscilator, LVDS poor connection ▶ Voltage used : 5V/3.3V/1.8V/2.5V (4 separate operating voltages). Solution Defect part Description of defect Part Defect display Replace Regular vertical Control CONTROL IC lines Board <...
  • Page 48: Drive Board

    Troubleshooting X Drive Board Voltages Supplied to the X Boards • From the Z SUS Board to both the Center • and Right X Boards. • From the Y SUS Board to the Left X Board • From the Z SUS Board to both the Center and •...
  • Page 49 Troubleshooting The Control Board supplies the Video Signal to the TCP ICs. If there is a bar defect on the screen, it could be a Control Board problem. Diagram of Control Board Control Board to X Board Address Signal Flow This will show Signal Flow Distribution to help determine the failed part depending on where the failure is on the screen.
  • Page 50 Troubleshooting TCP (Tape Carrier Package) : supplies RGB 6bit signal to the PDP by connecting the PAD Electrode of the PANEL with the X Board. Connector TCP IC Front side Behind side <IC Defect> Plasma Display Panel Troubleshooting - 2007...
  • Page 51 Troubleshooting Center X Drive Board P210 P200 P208 Output to TCP ICs Plasma Display Panel Troubleshooting - 2007...
  • Page 52 Troubleshooting Center X Board Connections on Connector P208 FL209 FL208 RGB Logic Signals RGB Logic Signals 31 Thru 34 VA (7,8,9) CLOCK 15 Thru 23 VA (42,43,44) 10 Thru 14 45 Thru 50 1 Thru 6 25 THRU 30 Grnd 37 Thru 41 Grnd Grnd 35 Grnd...
  • Page 53 X Board Voltage Distribution RGB Signals from the Control Board VA 5V GND L201 L202 P210 P200 C221 D201 C222 D202 C223 FL201 IC203 IC202 IC201 C241 FL212 FL210 FL206 FL214 FL208 FL204 FL202 FL213 FL211 FL215 FL207 FL205 FL203 FL209 RGB Address Signals out to TCP IC’s and PDP Plasma Display Panel Troubleshooting - 2007...
  • Page 54 Troubleshooting The X Board receives a Logic Signal from the Control Board and controls the Address Pulse (generates Address Discharge) by an ON/OFF operation, and supplies the waveform to TCP (data). X RIGHT B/D X RIGHT B/D X LEFT B/D X LEFT B/D COF Separating Lift up lock as shown in the Picture.
  • Page 55 X board Troubleshooting ▶ Major defect : Poor connection, Particle inserted. Defect name Description of defect Part Defect display Vertical abnormal display < Poor connection > Poor connection Vertical abnormal display Attached particle Check for attached particle or poor Vertical line connection ( similar with IC fail ) either one is possible.
  • Page 56 Vertical Line Troubleshooting Disconnect TCP, Check for a possible particle, if found remove with compressed air or soft fabric. If 1 vertical line can not be resolved by this, then the defect can not be repaired and the PDP will need to be replaced.
  • Page 57 Troubleshooting Control Board : If the buffer IC has failed, there can be vertical lines. The defect can not be repaired if the vertical line is caused by TCP IC failure. Root cause of TCP IC failure is ESD or Surge. <...
  • Page 58 Troubleshooting Cable description This is total collection of cables in PDP circuit , ⑫ Cable No. Purpose 8 9 10 Supply Va,5V to X B/D ⑥ ⑭ 2 3 4 RGB Video signal ⑬ FET driving signal to ⑦ make the Y waveform ⑤...
  • Page 59 Troubleshooting When each cable disconnected. Cable No. When disconnected 8 9 10 The section of the X board where the cable is disconnected will not show the screen. 2 3 4 The section of the X board where the cable is disconnected will not show the screen. No display (no Y waveform ) No display ( CTRL board will not be operated ) No display ( no 5 V )
  • Page 60 Dual Scan Y SUS Board Voltage Distribution VS VA VSC TP IC17 Logic VSC Floating Ground Signals From IC303 15v IPM Control -VY TP R132 SUS_UP SUS_OUT VSC Floating SUS_DN Ground ER_HIGH ER_UP Logic signals ER_I0 ER_DN from the VS_2 Control BD ER_ LOW for IPMs and...
  • Page 61 How to check IPM (Dual Scan) Troubleshooting (Resistance ‘Diode Check’, board removed from set) For both IC2 and IC7 Forward Test : 1. +VS ( - ), SUS_OUT ( + ) 2. SUS_OUT ( - ), CH GND ( + ) 3.
  • Page 62 Module check point Troubleshooting Y SUSTAIN Board VSC / -Vy Measurement Y-BOARD VSC R53 Both ends Y-BOARD VSC C51 Both ends -Vy R78 Both ends -Vy R36 Both ends Plasma Display Panel Troubleshooting - 2007...
  • Page 63 Module check point Troubleshooting Z SUSTAIN Board VzBias Measurement Z-BOARD Vzbias Z-BOARD Vzbias GND-Q18 R23 Both ends Plasma Display Panel Troubleshooting - 2007...
  • Page 64 DUAL SCAN PDP 50PX2 Waveform -Vy test point, Adjustment Vsc test point, Adjustment Test point Variations in the PCB design will result in variations in The signal driving the PDP panel. Refer to the label on the Y-SUS PCB match this number to the correct signal in this manual.
  • Page 65 DUAL SCAN PDP 50PX2 Normal Y-SUS PCB #038C Plasma Display Panel Troubleshooting - 2007...
  • Page 66 V-Set DN too low DUAL SCAN PDP 50PX2 All of the center washes out due to decreased Vset_DN time. V-Set DN too high The center begins to wash out and arc due to decreased Vset_DN time. Plasma Display Panel Troubleshooting - 2007...
  • Page 67 V-Set UP too Low DUAL SCAN PDP 50PX2 The center begins to wash out and ark due to Vset_UP Peeking too late and alters the start of the Vset_DN phase. V-Set UP too High Very little alteration to the picture, the wave form indicates a distorted Vset_UP.
  • Page 68 Ramp-UP too low DUAL SCAN PDP 50PX2 Noticeable low level color distortion with the Ramp_up too low. Ramp-UP too high Noticeable low level color distortion with the Ramp_up too high. Plasma Display Panel Troubleshooting - 2007...
  • Page 69 DUAL SCAN PDP 50PX2 Normal Y-SUS PCB #038B Plasma Display Panel Troubleshooting - 2007...
  • Page 70 Vset-DN too low DUAL SCAN PDP 50PX2 All of the center washes out due to decreased Vset_DN time. Vset-DN too high The center begins to wash out and arc due to decreased Vset_DN time. Plasma Display Panel Troubleshooting - 2007...
  • Page 71 Vset-UP too low DUAL SCAN PDP 50PX2 The center begins to wash out and ark due to Vset_UP Peeking too late and alters the start of the Vset_DN phase. Vset-UP too High Very little alteration to the picture, the wave form indicates a distorted Vset_UP.
  • Page 72 DUAL SCAN PDP 50PX2 Ramp-UP too low Noticeable low level color distortion with the Ramp_up too low. Ramp-UP too high Noticeable low level color distortion with the Ramp_up too high. Plasma Display Panel Troubleshooting - 2007...
  • Page 73 DVR Operation and Troubleshooting Plasma Display Panel Troubleshooting - 2007...
  • Page 74: Theory Of Operation

    Theory of Operation Plasma Display Panel Troubleshooting - 2007...
  • Page 75 Hard Drives the Beginning Hard disks were invented in the 1950s. They started as large disks up to 20 inches in diameter holding just a few megabytes. They were originally called "fixed disks" or "Winchesters" (a code name used for a popular IBM product).
  • Page 76 Hard Drives Today Hard drives have now become very small and can store massive amounts of data. As of 2005, over 98% of the world's hard disks are manufactured by just a handful of large firms: Seagate, Maxtor (acquired by Seagate in May 2006), Western Digital, Samsung, and Hitachi which owns the former disk...
  • Page 77 LG uses Seagate Hard Drives The 160 Gigabyte Barracuda Hard Drive from Seagate is built into several models of LG televisions and provides about 15 hours of HDTV recording or 66 hours of SDTV recording without the need of any external accessories.
  • Page 78 P/N 5040V00101B *Rubber changed from hard material to soft material LG recently started replacing the HDD that was designed for PC use (P/N:6744B00040A) with a low-noise HDD designed for A/V use (P/N:6744B91953A). The original HDD is shown on the right and the upgraded version is shown on the left.
  • Page 79 Hard Drive Control The HDD is controlled by IC1002 on the digital board Plasma Display Panel Troubleshooting - 2007...
  • Page 80 Hard Drive Control The SiI3512 is a single-chip PCI to 2-port Serial ATA host controller. Based on a 32-bit 66 MHz PCI interface, the SiI3512 provides support for two independent Serial ATA devices. The second Serial ATA output is used to control the memory card reader if the unit has that option.
  • Page 81 IC100 is the AMCC PowerPC. It controls the Serial Host controller IC1002. Plasma Display Panel Troubleshooting - 2007...
  • Page 82 The 405 CPU core is 100% PowerPC compatible and possesses all of the qualities necessary to make powerful and cost effective system-on-a-chip designs a reality. Optimized interfaces to the Core Connect bus structure provide for a high bandwidth, low latency system interface solution.
  • Page 83 Let’s put it all together HDD/DVR CPU IC100 Serial ATA Bus Serial Host controller IC1002 Plasma Display Panel Troubleshooting - 2007...
  • Page 84 1394Link TP_V0(PDR_PE OOB(DCR) (IC900) 1394_IN_TP MUX CPLD TSB43DA42 TPNII Tuner TPN_T (CN1102) TP_V (IC1100) (LGDT1303) (TU500) 1394_OUT_TP TP_ENC VSB/ LG POD VSB_T ATSC/NTSC Controlle POD_TP0 Tuner 1394_OUT_TP TPN_T /0x1C (TU301) VSB_T POD_TP0 TPNII TP_ENC TP_V0 NTSC Tuner MPGE ENCODER 1394_OUT_TP...
  • Page 85 Here’s what we can do Watch Live TV with Watch Live TV Watch Delayed Live 1 hour buffering Without buffering TV (1 hour max) Record one show and Record one show and Play Recorded show play a recorded show watch another live ** ** You can only record or watch one Digital Channel at a time however you can record one Analog Channel and watch another Analog Channel at the same time.
  • Page 86 X Studio is the Customer Interface to the DVR • Home Menu Consists of: • Home Menu Consists of: - Recorded TV - Recorded TV - TV Guide - Photo List - Schedule - Music List - Manual Rec - TV Guide - TV Menu - Reservation - IEEE 1394...
  • Page 87 HDD Free Space is only an estimate Record 1 hour of SDTV (480I) * This is a completely blank HDD Because video compression is used you can see that the HDD only shows 12 minutes of HD time or 27 minutes of SD time has been used to Record 60 minutes of SDTV Record 1 hour of HDTV (1080I) In this case you can see that the HDD shows...
  • Page 88: The Progress Bar

    The Progress Bar The Progress Bar can be brought up at any time by pressing the ENTER button To make the Progress Bar disappear you can either press ENTER again, press EXIT or simply wait about 10 seconds The bar will be blue during delayed playback The bar will be red during recording The bar will be green during playback of a recorded show Plasma Display Panel Troubleshooting - 2007...
  • Page 89 HDD ERROR MESSAGES Plasma Display Panel Troubleshooting - 2007...
  • Page 90 Timer Recording Fail-1 Message Note Timer recording cannot start due to HDD error. HDD problem. Bad sector or bad connection or other Timer recording cannot start due to bad signal. Signal strength is too weak to start recording Timer recording cannot start. No recording space. HDD recording space is full Timer recording cannot start.
  • Page 91 Timer Recording Fail-2 Message – timer record failed programs in RecordedTv list Note Timer record failed due to no disk space. HDD recording space is full Timer record failed due to no signal. Signal strength is too weak Timer record failed due to DVR device error. Device problem.
  • Page 92 Recorded Program Error Message - From Gemstar Guide PlayList Note Cannot play Recorded Program due to bad sector. Do you want to HDD bad sector. Select “YES” to delete the program delete? Cannot play Recorded Program due to copy protection. Do you want to copy protected.
  • Page 93 Recording Operation Error Message Note Recording halts due to HDD problem. HDD problem. Recording stops Stop recording due to copy protection. Copy protection detected during recording. Cannot record due to copy protection. Copy protection detected before recording starts. Do you want to stop recording before power off? “Yes”...
  • Page 94 Timeshift Operation Error Message Note Timeshift stops because of HDD problem. HDD problem. Bad sector or bad connection or other Timeshift cannot start. Audio only program. Cannot Timeshift audio only channel Timeshift cannot continue. Audio only program. Cannot Timeshift audio only channel Timeshift halts due to HDD problem.
  • Page 95 Rename Message Note Please input new title. Must type new title First character must be 0~9, a~z, A~Z. Please change new First character must be 0~9, a~z, A~Z title. Folder with the same name exist. Must change folder name. same folder already exists Reached maximum number of characters.
  • Page 96: Memory Card

    Memory card Message Note Unable to create folder. Reached maximum number of Maximum number of folder is 30. folders. Unable to create folder. No disk space. HDD is full. Must delete a program/photo/music before record. First stop copying and retry M/C eject. Cannot eject while copy operation is in progress Copy protected.
  • Page 97 HDD Recovery Message Note Bad sector occurred in critical regions of photo drive. Do you want to format Bad sector. Format photo-list photo drive? Bad sector occurred in critical regions of music drive. Do you want to format Bad sector. Format music-list music drive? Bad sector occurred in critical regions of HDD.
  • Page 98: Troubleshooting

    TROUBLE SHOOTING Eliminate the HDD • If you suspect the HDD is causing a video or audio problem you can simply unplug it • You MUST unplug the TV before disconnecting or reconnecting the HDD • During initial power up the TV will detect whether or not the HDD is there and will route the audio and video as needed Plasma Display Panel Troubleshooting - 2007...
  • Page 99: Dvr Trouble Shooting

    DVR TROUBLE SHOOTING Check HDD Power cable. #1: 5V, #4:12V Check HDD Signal cable (SATA) Check HDD power cable Check SiI3512(IC1500) inputs: Power pins, Osc • Check LED150 blinking • Check PCI bus Check HDD Signal Cable(SATA) Check CPLD(IC900) inputs: Check CPLD(IC900) outputs: Check SiI3512 Power pins, Osc, PCI Bus, LED150...