Air Force Pro 60 Operation & Maintenance Manual

Air force pro 15; 40; 60; 80 linear air pump, oil-less compressor

Advertisement

Air Force Pro™ Linear Air Pump
Oil-Less Compressor
Operation & Maintenance Manual
IMPORTANT:
PLEASE READ THIS MANUAL COMPLETELY.
Models
SAVE THIS MANUAL FOR FUTURE REFERENCE AND KEEP IN CLOSE
PROXIMITY TO THE AIR PUMP.
40
60
80
40
60
80
LINEAR AIR PUMP
Oil-Less Compressor
Air Force Pro™ Linear Air Pump
Operation & Maintenance Manual
Oil-Less Compressor
Operation & Maintenance Manual
IMPORTANT:
PLEASE READ THIS MANUAL COMPLETELY.
SAVE THIS MANUAL FOR FUTURE REFERENCE AND KEEP IN CLOSE
PROXIMITY TO THE AIR PUMP.
Thank you for purchasing Air Force Pro™ Linear Air Pumps.
It is manufactured to the highest standards using quality
materials. Please follow all recommended maintenance,
operational and safety instructions and you will receive
years of trouble free service.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 60 and is the answer not in the manual?

Questions and answers

Summary of Contents for Air Force Pro 60

  • Page 1 SAVE THIS MANUAL FOR FUTURE REFERENCE AND KEEP IN CLOSE PROXIMITY TO THE AIR PUMP. Thank you for purchasing Air Force Pro™ Linear Air Pumps. It is manufactured to the highest standards using quality materials. Please follow all recommended maintenance, operational and safety instructions and you will receive years of trouble free service.
  • Page 2 WARNING ※ IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS ※ TO REPLACE OR CHANGE ANY OF THE PARTS REFERRED IN THE SERVICE MANUAL, WE STRONGLY RECOMMEND YOU CONTACT AN AUTHORIZED TECHNICIAN. DANGER --To avoid possible electric shock, special care should be taken since water is used with or near aquariums and reservoirs.
  • Page 3: Cautions For Use

    If the plug or outlet does get wet DO NOT UNPLUG THE CORD; Disconnect the fuse or circuit breaker supplying power to the pump, then unplug and examine for the presence of water in the outlet. DO NOT use the pump near volatile liquids such as gasoline, thinners, etc,. as this creates the possibility of an explosion.
  • Page 4: Grounding Instructions

    SAVE THESE INSTRUCTIONS GROUNDING INSTRUCTIONS For all grounded, cord-connected products: This product must be properly grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug.
  • Page 5: Operation

    This product must be connected to a grounded, metallic, permanent wiring system, or an equipment-grounding terminal or lead on the product. Power Supply must conform to all required safety codes and be installed by a qualified electrician. Check and Read rating labels listed on product name plate for supply voltage. For a permanently connected product: Extension Cords: Use only a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle...
  • Page 6: Maintenance

    Start Up If pump fails to start or slows down significantly under load, shut off and disconnect from power supply. Check that the voltage is correct for the pump. MAINTENANCE Disconnect electrical power supply cord before performing maintenance on this product. Failure to follow these instructions can result in death, fire or electrical shock.
  • Page 7 Maintenance Manual Maintenance Manual Air Force Pro™ 15 Part No: 746500 IMPORTANT: To open upper enclosure, please make sure you have unplugged the power cord before opening. unplugged before opening 1. To change the diaphragms A. Remove the four screws around the aluminum upper housing, and take the housing off.
  • Page 8 Product View and Parts List Product View and Parts list Air Force Pro™ 15 Part No: 746500 DESCRIPTION UPPER HOUSING ELECTROMAGNET CHECK VALVE WIRE STOPPER U-SHAPED COIL FRAME VIBRATION CONTROL ACTIVATING ARM RUBBER DIAPHRAGM DIAPHRAGM FRAME U NUT DIAPHRAGM HOUSING...
  • Page 9: Product Specifications

    Product specifications Product Specifications Air Force Pro™ 15 Part No: 746500 < 26 dBA 20 - 80 2.54 kg Voltage Frequency WATT Part No. (VAC) (HZ) 746500 110 ~ 120 0.43 NOTES: All dimensions are for reference only. Technical data subject to change without notice Performance Allowance ±5%...
  • Page 10 Maintenance Manual Maintenance Manual Air Force Pro™ 40, 60, 80 Part No: 746505, 746510, 746515 1. To clean the air filter Recommended once every six months A. Remove the screw on top. (As shown in Figure1) B. Remove filter cover.
  • Page 11 Product View and Parts List Product View and Parts list Air Force Pro™ 40, 60, 80 Part No: 746505, 746510, 746515 DESCRIPTION TOP SCREW FILTER COVER FOAM SEAL FILTER UPPER HOUSING THERMAL PROTECTOR ELECTROMAGNET WIRE STOPPER U-SHAPED COIL FRAME VIBRATION CONTROL RUBBER...
  • Page 12 Product specifications Air Force Pro™ 40 Product Specifications Part No: 746505 < 46 dBA 20 - 80 6.09 kg Voltage Frequency WATT Part No. (VAC) (HZ) 746505 110 ~ 120 Performance NOTES: All dimensions are for reference only. Technical data subject to change without notice.
  • Page 13 Product specifications Product Specifications Air Force Pro™ 60 Part No: 746510 < 47 dBA 20 - 80 6.99 kg Voltage Frequency WATT Part No. (VAC) (HZ) 746510 110 ~ 120 Performance NOTES: All dimensions are for reference only. Technical data subject to change without notice.
  • Page 14 Product specifications Air Force Pro™ 80 Product Specifications Part No: 746515 < 51 dBA 20 - 80 7.05 kg Voltage Frequency WATT Part No. (VAC) (HZ) 746515 110 ~ 120 Performance NOTES: All dimensions are for reference only. Technical data subject to change without notice.
  • Page 15: Limited Warranty

    Supply, Inc. This unit is built to the highest standards using quality materials. To ensure the life and performance of your Air Force Pro™ Linear Air Pump a change of the diaphragm and air filter every year is absolutely necessary for users.
  • Page 16 Exclusively distributed by:...